Germany, Neuenrade
... as variants in which the CSN® Current Sensor will be mounted hanging in the busbar. Schniewindt has implemented CSN® Current Sensors for nominal currents of up to 5 kADC at system voltages of 800 kVDC, which have been successfully typetested. Also for the precise measurement of small currents (1 to 10 A), such as transient currents in capacitor banks, Schniewindt offers appropriate solutions. All of our CSN® Current Sensors are individually designed according to customer requirements. ...
Germany, Waiblingen
...Our calibration technology is continuously developed in parallel with our flow and flow sensors. We calibrate on numerous test benches equipped with state-of-the-art measurement technology. The calibration of all measuring devices is carried out in accordance with a certified quality assurance system according to DIN EN ISO 9001. The DAkkS accreditation of our calibration laboratory for the...
We are the manufacturer and supplier of the contactless measuring system I-W-A, eddy current sensors for precise fast distance measurements, as well as your specialist for DMS applications and on-site measurements. We are your professional contact with over 25 years of experience in the following areas: Measurement technology, telemetry, electronics development (hardware and software), industria...
France, Lisses
...Current Sensors Features: • AC, DC, and impulse currents • Competitive cost/performance ratio • Low power consumption Benefits: Based on the principles of the Hall-effect wherein a Hall-effect device...
Slovenia, Šentjernej
We have five decades of globally recognized experience in the production of thick-film hybrid circuits, pressure sensors, custom-made products, and medical devices. We provide a full range of services covering processes from development to series production to create custom products based on our customer’s needs. The hybrid technology used in the HYB manufacturing process combines different techno...
Germany, Otterfing
...Eddy Current Series AX2 - High-Precision Analog Eddy Current Sensors Measuring Ranges: 0.5 - 10 mm Max Linearity: ±2 % Max Resolution: 0.03 µm Dynamics: 10 kHz Protection Class: IP68 Operating Temperature: up to +185 °C Output: 10 V, 5 V...
Germany, Ortenburg
Micro-Epsilon stands for innovation and continuity, as well as for sustainable growth and the pursuit of greater precision. The portfolio includes sensors for displacement, distance, position, thickness, 2D/3D measurement technology, laser scanners, micrometers, fiber optic sensors, sensors for color detection and color measurement, infrared temperature sensors, thermal imaging cameras, sensors fo...
... not be influenced by dirt particles or other influences. No electrical current is sent through the medium via an electrode with BEDIA sensors, an electrolysis of the medium is not possible. Operating Principle The function of the sensor is based on the capacitive principle. It detects the change in capacitance that arises when an electrode surrounded by air is immersed into a liquid medium. This change in capacitance at the electrode of the sensor excites an oscillator, causing it to oscillate. Then this signal is processed by a microprocessor-based evaluation circuit.
Belgium, Fernelmont
... watertight to IP66. We have a proven track record of several thousands of such sensors operating reliably around the world.TYPICAL USE Permanent outdoor monitoring of tall structures FEATURES Acceleration measurements along 2 axes Temperature measurement of the surface the sensor is attached to Signals transmission through 4-20mA current loops Embedded Lightning Protection Operation down to -40°C MODELS Standard High Resolution...
...By combining the RTR505B with various optional modules, it is possible to measure temperature (Pt100/Pt1000, thermocouple sensors), voltage, current (4-20mA), and pulses. Additionally, this type is equipped with a high-capacity battery. Data can be transmitted from a logger to a base unit and then automatically uploaded to a cloud storage or saved at a specific location. The data can also be...
...Equipped with a robust housing and a stainless steel measuring element, the sensor is particularly resilient and suitable for the harshest environmental conditions; the installation position has no influence on the measurement signal. The integrated signal amplifier converts the measurement signals directly into interference-resistant voltage or current signals that can be transmitted over longer...
Switzerland, Winterthur
...The differential pressure transmitters of the PD-39X series measure the pressure difference indirectly using two absolute pressure sensors. The dual-sensor design with numerical differential formation also outputs the line pressure values via the digital RS485 interface and guarantees a high overload resistance. The additional analog current or voltage output is primarily used to output the...
Germany, Buchenbach
...The Digimes Universel is a 5 KHz carrier current bridge for resistive, inductive or differential transformer transducers connected in full or half bridge. The sensitivity is adjustable by the user between 2 mV/V and 100 mV/V according to six measuring ranges. Gain and offset can be adjusted with potentiometers to allow calibration of the sensor. There is also the Digimes Compact, dedicated to one sensor.
Germany, Gschwend
...Measuring ranges from 0.5 to 1000 Nm • Current and voltage output • Measurement accuracy ≤ 0.25 % • Contactless signal transmission • Proven strain gauge technology • Built-in measurement amplifier • Simple power supply • Universally applicable • Optional speed measurement...
Germany, Ettlingen
... spectral ranges and two measuring ranges. This allows the sensors to be optimally adapted for the application. The integrated electronics produce a signal that is transmitted to the PLC or panel meter, so that inferences are minimized. Operating voltage and output signal can be selected to match the measurement task or PLC interfaces. For small control tasks, the sensor UVX-SE can be connected to RM-32...
Germany, Herrenberg
United Kingdom, Haverhill
...ProxATEX ATEX/IECEx Certified Temperature Controller – New Patented High Current Hazardous Area Controller This ATEX and IECEx certified controller is ideal for use with our Thermosafe, Faratherm or InteliHeat FlexiPlus products and other heating equipment installed in potentially explosive atmospheres. The device features Near Field Communication (NFC) which allows operators and site managers...
...EGE sensors for fluid mediums with integrated measuring & amplifier are compact devices with extremely robust housing and integrated measuring and amplifier. The current flow state is displayed at the sensor using LEDs. The measurement takes place without mechanically moving parts using a thermal measuring element. Limit values are set directly at the device. These sensors are used wherever a...
... on the vehicle performance and the service life of the tyre. Range:0 to 200 °C Accuracy:2 % FS Ambient temperature error:2 °C Sensitivity:20 mV/°C Response time (0-90%):250 ms Signal:0.5 at 0°C V Supply Voltage:5 to 16 V Supply Current:1,5 mA Output Voltage:0 to 5 V Output Impedance:47 Ω Sensitive Element:Thermopile with Silicium Lens Wave Length:8 to 14 µm Measurement distance:30 to 150 mm...
Switzerland, Rossens
... range of temperatures and pressures, even in the most extreme applications. The DI sensor produces a direct output signal of 4 to 20 mA corresponding to the measurement range, as well as a temperature output in VDC. An optional Magtrol signal converter of type CST 113 is available, allowing for the calibration of the measurement chain according to specific needs for current or voltage output. Wide...
France, Fontaines Les Gres
...Housing aluminium. Cable sheath PVC. Version Compact sensor and plug design. Flat connector, 8pole, 1x pin. Connection cable, 6wire, ø 3.55–0.3 mm. Cable bend radius, > 17 mm (static). Note Works with magnetic tapes 21725. The reading distance between the sensor and tape must be 0.1 to 2 mm. The sensor is supplied with operating voltage and draws current via the electronics. System accuracy...
Belgium, Jumet
... zero signal (% F.S.*/10°C):< 0.1 Zero signal (V):5 Safe load limit (% F.S.*):130 Power supply (-):5...28 VDC Consumption (max.) (mA):37...45 Nominal sensitivity (V):± 4 Start-up current (mA):< 100 IP rating (-):IP50...
United Kingdom, Dorrington
...The Rotonivo® rotary paddle level switch from UWT operates reliably and maintenance-free and offers a compatible solution for plants for safe level detection in bulk solids. It has all current international approvals for use in gas and dust explosive atmospheres and is one of the first rotary vane detector certified according to SIL 2. Overfill protection and no-load protection are guaranteed for the long term. The three Rotonivo® rotary paddle level sensor series RN 3000, RN 4000 and RN 6000 cover the complete range of applications, from simple to extreme.
Belgium, Gembloux
... class H available upon request - Stored speeds: 3000 rpm or 1500 rpm or 1000 rpm or 750 rpm - Efficiencies IE3/IE4 (soon IE5) - For 8 poles, we have IE1 and IE3 as there are currently no standards above 375kW - and up to 1,400kW - Frame types B3-B5-V1-B14-B35-V15-B34 - Standard motors equipped with PTC sensors from size 132 - Standard motors in sizes 315-355 equipped with NU bearings at speeds of 4-6-8 poles - Standard motors in sizes 355X-400-450-500-560 equipped with NU bearings at speeds of 4-6-8 poles...
United Kingdom, South Croydon
... and you must to stop; (3)Five sets lights in three colors (green denotes safe, yellow denotes warning, red denotes stop), two sides lights indicate the orientation of obstacles, the number indicate the distance between obstacle and vehicle. Technical specification: Working voltage: 10V~15V OR 24V; Working current: ≤200mA; Max Power: ≤4W; Ultrasonic frequency: 40KHz; Working temperature: -30℃~ +70℃; Alarming volume: ≥63dB; Alarming distance: 1.5~0.1m; Display distance: 2.5~0.3m.
...Weather sensors ensure that irrigation is temporarily suspended due to natural precipitation, wind, or frost. Soil moisture sensors stop irrigation when the set moisture level has been reached. The Solar Sync® weather sensor automatically adjusts the irrigation duration based on current weather conditions. With the help of a flow sensor, flow rates can be monitored. The sensors are designed to optimize irrigation in such a way that, on one hand, water can be saved, and on the other hand, to protect green areas and plants from overwatering and the potential damage that may result.
...Specification — 4-pole rotor with NeFeB magnet impregnated plastic — Triple strand coil switched in a triangle — Internal Hall sensors at 120° for rotor position — Aluminum housing — Machined aluminum bearing supports — Bearings at both ends AC/DC: 3-phases Type: brushless Voltage: 12V Other features: 4 poles, precision...

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store