...decentralized signal acquisition, robust and precise. µCAN-Transmitter Series: Protection class IP 67, space-saving integration directly in the measurement line of temperature and strain gauge sensors. µCAN-OEM Series: CAN bus connection directly in the sensor housing, equipped with a high-speed CAN interface that supports CAN 2.0A and CAN 2.0B. Analog Acquisition: Temperature, pressure, current, voltage Digital Acquisition: Input and output Bus System: CAN, CAN FD Protocols: CANopen, CANopen FD, J1939...
... control technology for pump control. Magnetic-inductive flow meters are reliable and economic compact units or installation in the pressure line and are available in two basic versions: Sensors for pipe installation with integrated measuring transducer and on-site display as a compact unit Sensors for pipe installation with separate measuring transducer. With this version, the measuring transducer can be located separately on the wall in the service building or as a fitted housing directly in the AWAcontrol control cabinet. ...
France, Chambray Les Tours Cedex
...Presentation of current sensor and transmitters Download the manual DESCRIPTION: SC-650 Series The current sensors of the SC-650 series monitor the current line for electrical loads such as pumps, conveyors, machine tools, or fans and feature a 0-5 VDC output signal to represent the load current. The SC-650 series requires no external power supply as it is fully powered by the induction from...
Germany, Jena
...Are you using an ATMION® wide-range vacuum gauge for pressure measurement and experiencing issues? Or are you looking for a replacement sensor? Contact us! As a long-standing manufacturer of the ATMION® wide-range vacuum gauge, we are your personal contact in case of service needs or if you require a replacement sensor. We also offer a comprehensive and prompt repair service for all other devices we manufacture, whether from current or previous product lines, such as the MVC-3. Just reach out to us!
... On request, in addition to the magnetic sensor listed here, other versions are also available. Technical Data Magnetic Sensor (M936-1-000) - Switching function: closing - Output technology: PNP - Rated switching field strength: H 1.2 kA/m - Hysteresis: max. 45% of Hn - Operating voltage: 10 to 30 V DC - Residual ripple: max. 15% - Rated operating current: 200 mA - No-load current damped/undamped...
Germany, Mainz
...The AMS 4712 series consists of ready-to-install pressure transmitters suitable for absolute pressure, relative pressure, and differential pressure measurement. They are designed for industrial applications and feature a current output. The transmitters are unilaterally media-resistant due to back pressure compensation and are delivered in a robust and compact plastic housing (IP67) for quick...
... poisoning ● Long lifetime ● Pump current switch type, conventional switch type, air-fuel ration type, and wide range type are available Appliaction: Plate Ceramic Heater Chip for Automobile / Oxygen Sensor High Temperature Insulation Resistance: :@800℃,≥1 MΩ Operating voltage::7V - 14V Light-Off Time: :≤10 s voltage: :3.7-220V Heater Resistance: :2.1Ω±0.5Ω Dimension(L*W*H)::Customized...
ufs.country_names.RU, Zarechny
...it is possible in some cases to use the sensor to protect two grids welded by the metal rod, Like this we decrease expenses. Vandal-proof housing makes it impossible to dismount the sensor without opening the cover. Under the cover there is the tamper. Easy design and reliable sensors are well protected from climatic effects. Protected surface:10 m2 Supply Voltage:6…30 V Current consumption:0,002 A Detection probability:0.98 Operational temperature:minus 45...+65 °C Protection Level:IP-65 Alarm output:Relay contacts Dimensions:90x58x65 mm Weight:0,25 kg...
Czechia, Prague
Germany, Hohen Neuendorf Ot Bergfelde
... Assigned Rogowski Sensors (Ø80-142-190mm) Voltage: 80…500V (Phase-Phase) – VT Transformer Translation Programmable External Current Sensors Programmable Phase Sequence Correction, Diagnosis THD and Harmonic Content Analysis Auxiliary Voltage: 80…265Vac / 100…300Vdc...
...) of 90 dB for excellent noise immunity, as well as a Unit-Weight of 0.004938 oz. This low-power amplifier is perfect for a wide range of applications, such as charge measurement, bio-sensing, optical strain measurement, bridge-sensor amplification, and motion control current sensors. Its user-selectable gain and bandwidth can further tailor device performance for a variety of low-noise applications...
Germany, Nürnberg
...Speed sensor FAW52 / eddy current / IP66, IP68, IP69 / status signal - Non-contacting multi-channel stainless-steel speed sensor, eddy current principle. Due to its design and type approval according to DIN EN 50155 especially suitable for transport technology. Scanning of all electrically conductive materials (steel or aluminium). Insensitive against mechanical abrasion (metal chips). Robust...
Netherlands, Waalre
...Eddy current separators, or non-ferrous separators, separate non-magnetic metals (non-ferrous). They purify large flows of bulk material and/or separate non-ferrous metals for reuse. Eddy current separators have numerous applications. They can process large quantities because the conveyor belt automatically and continuously separates and discharges non-ferrous metals. For effective separation, it...
Germany, Oberhausen
... 50155 and meet the requirements of protection class up to IP 68. Customised versions by adapting the housing, or different cable and plug fabrication, Lenord+Bauer can implement almost any installation position. Depending on requirement, the sensors generate single or multichannel squarewave signals alternatively as voltage or current signal ranging from 0 to 25 kHz. A standstill signal can also be implemented. On request ATEXprotected product variants, special output signals for functional testing, and sensors with integrated pulse division or pulse multiplication are available.
Slovenia, Maribor
...SCQ25 COMBO QUADRO SHUNT MODULE SCQ25 is an innovative shunt module for monitoring individual consumers and generator with 4x current sensors up to 25A each. For 12V and 24V systems.
...Thanks to the True-Power-On function, any angle changes are registered even during a supply voltage interruption and the angle is reproduced exactly as an analogue signal as soon as the supply voltage is restored. The contactless sensor technology works on the basis of modern gradient-based magnetic field evaluation in processor-supported circuit design. This makes the multiturn encoder largely...
Switzerland, Schachen
...With a level sensor, liquid levels can be reliably and continuously measured. The sensors from Reed Electronics AG are designed for harsh conditions and various media. With a wide selection of materials and dimensions, we can find the right solution for every customer. The cost-effective sensors are used for continuous level measurement to inform the user of the current level in 0 – 100%, allowing for early response to an event or to calculate the number of process cycles.
... low membrane mass, the very low temperature dependence and an amplified signal in current modes enhance the measurement signals of the dual IR detector. Application:gas analysis Measuring gas:hydrocarbons Package:TO39 Aperture in mm:1.5 Channels:2 Temperature min. °C:-20 Temperature max. °C:85 Filling gas:Krypton...
Belgium, Waterloo
... commands. Analog output 4–20 mA and 0–10 V with automatic switching between current output and voltage output. Analog output plus 1 pnp switching output for proportional measurement to distance with an additional limit value. 5 detection ranges with a measurement range from 30 mm to 8 m, individually tailored for the specific use case. Teach-in microsonic via push button T1 or T2 for simple and uniform commissioning.
France, Rambouillet
...industrial environments, temperature, humidity, CO2, flooding, electrical current, etc. It works with various sensors and detectors and provides comprehensive management via SensDesk. Ideal for reliable monitoring of your equipment.
Germany, Dortmund
... settings on the sensors are made. The easily readable three-digit LED display continuously shows the current distance value and automatically switches between mm and cm display. Two buttons located below the LED display are used to access the parameterization and navigate through the self-explanatory menu structure. The switching points of the switching outputs and the window limits for the analog output can be numerically preset using the digital display, without the need for the object to be measured to be within the detection range.
Slovakia, Trenčín
...Universal membrane force sensor for general use. The load to be measured is applied via external threads. Suitable for use in manufacturing plants as well as in laboratories and testing. Range: from 50 N up to 5 kN Force dir: Tension / Compression Version EMS21 has built-in signal conditioner with voltage or current output.
France, Brain Sur L'authion
...Designed for long life. No brush maintenance. The motor is 92% efficient at voltages between 24 to 72 VDC. Continuous current of 125 amps AC (180 Amps DC into the motor control). This is a 3-phase, Y-connected Permanent Magnet Synchronous Motor with an axial air gap and 3 Hall sensors at 120 degrees electrical timing. It has two stators with a rotor in the center. Output Power of 10 KW...
Germany, Steinenbronn
...% Resolution infinite Connection resistance 5 or 10 kOhm Resistance tolerance ± 20% Load resistance Min. 100 kOhm Repeatability ≤ 0.01% Mechanical lifespan 100 million cycles Deflection speed ≤ 5 m/s Permissible applied voltage 28 VDC max Recommended operating current in the wiper circuit < 1 µA Electrical connections 4-pole Housing dimensions 33mm x 33mm Housing material anodized aluminum Push rod diameter 6mm Push rod material stainless steel Protection class IP 65 Operating temperature -20 to +80°C Mechanical mounting variable clamps...
Switzerland, Reinach Bl
...The Soliswitch FTE20 is an economical rotary paddle level detector for level detection in bulk solids. With its robust polymer housing and compact design, it is ideal for use in bulk solids as a full, empty, or replenishment alarm level sensor. The optimized polymers make the device extremely durable and, therefore, suitable for use in dust Ex zones in accordance with current standards...
Germany, Göttingen
...Calibratable liquid glass thermometers for measuring the current ambient temperature. These thermometers are also used as psychrometer thermometers according to August.

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play