• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • temperature switches

Results for

Temperature switches - Import export

Manufacturer/producer

Germany

Verified by Europages

The electronic temperature switch of BEDIA is fitted with thin-film resistor Pt 1000 in a bridge circuit. This sensor element provides close switch point tolerances and a quick response. Switch point and reset hysteresis may be selected within the admissible operating range when ordering so as to allow the monitoring of both very wide and very close temperature ranges. The switching output is protected from short-circuit and overload. The short-circuit current is limited by the output transistor switching off inthe event of a fault. It will automatically reset as soon as the fault has been remedied. The switch is available with ground-connected, plus-connected or potential-free DC switching output. The switch is open in the event of power failure or disconnection of the power supply, independed of the switching function. It is available both as normally open (NO) or normally closed (NC) switch.

Request for a quote

Germany

Verified by Europages

These high-power bimetal operated temperature switches are available either with normally closed (NC) or normally open (NO) contact configuration. The robust round metal enclosure accommodates a resilient preloading disk, a bimetal disk and a silver contact. The compact switch system is covered by means of a plate which also carries a silver contact and is isolated from the enclosure by means of an isolating washer. The resilient preloading disk ensures excellent performance. The resilient preloading disk keeps the contact pressure constant throughout the entire temperature range of the BEDIA switch until switching occurs. The mechanically and electrically unloaded bimetal disk snaps over at a preset temperature, with either opening or closing the contact arrangement. The bimetal will only snap back to its initial condition after the temperature has dropped significantly.

Request for a quote

Germany

Lance design and compact design Switching and range up to 200 C 4..20 mA/0..10V/ 2 x push pull Stainless steel material

Request for a quote

Germany

Lance design and compact design Switching and range up to 200 C 4..20 mA/0..10V/ 1 x push pull Stainless steel material

Request for a quote

Germany

Compact design, variable length Switching range -20 C to +100 C Transistor output 1 x push pull Stainless steel material

Request for a quote

Turkey

What is the Thermostat effect on the Fan? The thermostat in the cooling unit controls many of the electric fans. When the temperature in the engine gets to a certain preset temperature, the fan will begin cooling the engine. When the temperature dips below that preset temperature, the fan will turn off.

Request for a quote

Turkey

What is the Thermostat effect on the Fan? The thermostat in the cooling unit controls many of the electric fans. When the temperature in the engine gets to a certain preset temperature, the fan will begin cooling the engine. When the temperature dips below that preset temperature, the fan will turn off.

Request for a quote

Turkey

What is the Thermostat effect on the Fan? The thermostat in the cooling unit controls many of the electric fans. When the temperature in the engine gets to a certain preset temperature, the fan will begin cooling the engine. When the temperature dips below that preset temperature, the fan will turn off.

Request for a quote

Turkey

The fuel temperature sensor is one factor that tells the ECU how to adjust the amount of fuel injected. When the fuel is warm, it's less dense and burns more readily so the ecu injects more fuel to get the same mass of fuel and retards the timing. When the fuel is cold, it's more dense so the ecu injects less fuel and advances the timing. Hot fuel has the same effect as higher cetane fuel at a lower temperature because it burns more readily. Timing and injection quantity is also based on many other factors, fuel temperature is just one of them.

Request for a quote

Germany

Verified by Europages

Temperature is one of the most measured physical parameters. Despite this, precise temperature measurement is one of the most difficult tasks in motor technology. To meet the constantly increasing requirements for improved motor performance, higher efficiency and reduced emissions, it is necessary to use reliable and precise sensors in modern motor control systems. The increased requirements over the last few years regarding measurement accuracy and reliability of temperature measurements has meant that many equipment operators must reconsider the suitability and performance capacity of their temperature measurement equipment. Resistant thermometers can be used between -200 °C and +850 °C. An important common property is that their output parameters are available in the form of electric signals that can be relatively easily transferred to measurement and control instruments for processing, storage and display.

Request for a quote

Germany

Verified by Europages

This temperature sensor is for measuring the temperature of liquid and gaseous media in engines, sets of machines and utility vehicles. A Pt 1000 thin-film precision resistor is used as the measuring element. The temperature-dependent resistance of the Pt 1000 is evaluated by an electronic circuit and outputted as a temperature-dependent voltage at the sensor‘s output. The interrelationship between temperature and voltage corresponds to the characteristic curve for the Pt 1000 and is thus nearly linear. The assignment between temperature and output voltage is nearly freely selectable, the lesser temperature corresponding to the lesser output voltage. The sensor‘s lowest possible output voltage is 0.1 V and its greatest is 10 V. The output is overload-proof and short-circuit-proof. The sensor has no mechanical moving parts and so is not susceptible to vibration and soiling.

Request for a quote

Germany

Verified by Europages

Tank gauges, oil pressure gauges, oil temperature gauges, boost pressure gauges, ammeters and voltmeters for additional installation. All items are from wellknown manufacturers in the field of display instruments

Request for a quote

Germany

Verified by Europages

In order to meet the demands for robustness and efficient heat output, we have embroidered the heating element on a glass mesh fabric carrier material. Between the meandering arrangement of the heating strands, we integrate a recess for the temperature switch in the CAD layout. In addition, a second wire is laid concurrently as a PTC thermistor for the electrical connection of the safety switch. After the technical embroidery process, the safety switch is inserted and connected by our company’s respective department. Each prefabricated element is tested for functionality and performance in the final inspection and is delivered to the customer after passing the test. As a semi-finished product, the infrared heating element on glass mesh fabric can be further processed by the customer, e.g. in connection with silicone, rubber or epoxy resin.

Request for a quote

Italy

Verified by Europages

Dual heat multipurpose. Hand held constant heat sealer. Ideal for sealing clam shells or for tacking. Supplied with a high and low temperature control switch and proportional temperature control system. To spot seal OPS, PSP, PVC, and EPS food container.

Request for a quote

Germany

Verified by Europages

The eddyNCDT 3001 is a new, efficient, inductive displacement sensor based on eddy currents whose compact dimensions have to date only been reserved for inductive proximity switches. The temperature-compensated design provides high stability even in fluctuating ambient temperatures. The eddyNCDT 3001 comes with integrated electronics, offering an outstanding price/performance ratio and easy operation.

Request for a quote

France

Verified by Europages

Stainless steel 1.4305 Lamellar insert polyamide (PA6). Seal ring CR / NBR. O-ring NBR. Version: Bright. Note: DIN EN 60423 cable glands with metric thread. Sealing and tension relief are provided by inset fins and a sealing washer. Rating IP68 (5 bar for 30 min). Cable glands are used for connecting fixed calbes and lines in housings, distributors and switch boxes. Temperature range: Static: -40 °C to +100 °C. Dynamic: -20 °C to +100 °C.

Request for a quote

Germany

Verified by Europages

AccuBird® – Production • Developed and produced in Germany since 1992 by the inventor of the battery blind rivet setting tool Reliability • Electronic control • No mechanical switching components • Electronic temperature and overload protection • High reliability through low loss power transmission via a highly effi cient ball screw drive Freedom Cablefree tool for fl exible operation in installation jobs and industry production High performance • 10.000 N setting force • High pulling force for safe setting of blind rivets up to 5 mm diameter in all materials • High yield per battery charge • Large 20 mm stroke Versatility Blind rivets up to 5 mm Ø all materials. BULB-TITE® blind rivets 4 mm, 5,2 mm and 6,3 mm Ø alu and steel High speed • High speed of operation through automatic resetting of the jaw mechanism immediately after each setting process With Li-Ion energy • Choice of 2.0 Ah and 4.0 Ah Li-Ion batteries

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Verified by Europages

EGE amplifiers process the signals of the EGE filling level sensors for extreme temperatures at a safe distance and are used to set up the sensor via intuitive operation using potentiometer and LED strip. Amplifiers for EGE high temperature limit switches feature an auto-calibration of the switching point at the press of a button. EGE amplifiers provide switching signals or analogue signals, dependent on the device.

Request for a quote

Germany

Hygienic thread EHEDG-certified seal system Flush front and elastomer-free For tanks, containers and pipelines

Request for a quote

Germany

Parameterisation of LABO/FLEX/OMNI For Windows PC with USB Connection in device supply line Bypass mode for output signals

Request for a quote

Germany

The STAUFF Level-Temperature Switches (SLTS Series) are unique in their design and modularity. One of the greatest advantages is the ability of the end-user to adjust the switching level. The internal support wire carrying the level and temperature switches makes it a simple and quick job to change the level switch position. ▪ Suitable for Mineral Oil and HFC fluids, other fluids on request ▪ Either 1 or 2 level contacts available ▪ 1 integrated temperature sensor (optional) ▪ Standard electrical function: Level contacts: Normally closed, opens with falling level Temperature contacts: Normally closed, opens with rising temperature STAUFF Level-Temperature Switches SLTS are available with other electrical functions on request. ▪ 1 NPT and others availble on request ▪ max. 115 Volt switching (for thread N16 only) Materials ▪ Stem: Brass ▪ Float/Sealing: NBR (Buna-N®) ▪ Max. operating temp.: +80 °C / +176 °F Electrical Data and Output ▪ Max. current level contact: 0.5 A ▪ Max....

Request for a quote

Germany

Limit value switch for temperature (thermocouple). Simple application; for rough environments. Limit value freely adjustable by drum scale. Open-circuit or closed-circuit devices available. Compact and robust construction. Operating status indication by integrated LED. Approvals: BV, DNV-GL, LR

Request for a quote

Germany

Limit value switch for temperature (NTC thermistor). Simple application; for rough environments. Limit value freely adjustable by drum scale. Compact and robust construction. Approvals: BV, DNV-GL

Request for a quote

Germany

Limit value switch for temperature (NTC thermistor). Simple application; for rough environments. Limit value freely adjustable by drum scale. Open-circuit or closed-circuit devices available. Compact and robust construction. Operating status indication by integrated LED. Approvals: BV, DNV-GL, LR

Request for a quote

Germany

Limit value switch for temperature (Pt100/Pt1000). Simple application; for rough environments. Limit value freely adjustable by drum scale. Open-circuit or closed-circuit devices available. Compact and robust construction. Operating status indication by integrated LED. Approvals: BV, DNV-GL, LR

Request for a quote

Germany

KLN manufactures various cleaning machines acc. to ATEX (ATmosphère EXplosibles) for the use of combustible liquids. The cleaning machines can be used separately or in combination with other methods. The cleaning tanks must be operated at a well ventilated place. The combustible cleaning agent can be filled in directly into the tanks. The ultrasonic generators are set up separately. A safety thermostat (setting 15°C below the flash point) controls the adherence to a max. temperature and in case of excess temperature it switches the machine off. The cover included in the delivery avoids emissions from the tank during standstills. The machines can also be used in connection with aqueous cleaning methods. Options: • heating • extraction • cooling tube • ultrasonic frequencies 30 and/or 40 kHz • automation system • product carrier

Request for a quote

Germany

• temperature sensor from stainless steel • switch between °C and °F possible • measuring range: 0°C to +200°C / 32°F to 392°F • automatic switch-off function after 5 minutes • Includes batterie 1 x CR 2032, 3V

Request for a quote

Germany

The temperature switch GP2610 in clamp-on technology is intended for measuring the surface temperature of pipes especially in food/pharmaceutical/biotechnology applications. The output signal is connected to a digital PLC I/O port. ■ Various clamping elements for process connection ■ Hygienic temperature measurement for pipe diameters of 4…300 mm ■ Measuring system patented ■ High accuracy, fast response ■ Easy installation ■ No welding, no process interruption ■ No additional isolation required ■ Measuring insert can be recalibrated ■ Temperature switch with output signal 4 or 33 mA, 2-wire technology ■ Switch point setting by using a magnet; range from -40 to +150 °C ■ Switching point accuracy ± 0,5 K ■ Switching delay: 0 sec ■ Hysteresis 0.1 K ■ Switch state indicator with 2 LEDs (green light) ■ Electrical connection M12

Request for a quote

Germany

0-29 in HgV (to 33 mbar abs) If you thought you couldn't afford the water costs associated with operating a liquid ring pump…think again. One of the wonderful features of the liquid ring pump is that it can be operated with a multitude of different fluids. A self-contained oil sealed system has a number of benefits over a traditional water sealed system: It eliminates water usage and disposal costs; it allows you to install it in remote locations where water may not be available; it allows you to attain higher vacuum levels than with water; it can prevent the condensing or dissolving of a process gas; it permits anhydrous processing with a liquid ring pump. Self contained system complete with off of the components for your basic operating needs. Standard components include: pump, TEFC motor, coupling or v-belt drive, drive guard, separator with oil mist eliminator, air cooled heat exchanger, recirculated seal line controls and high temperature alarm switch. Options include: inlet isolation valve, inlet check valve, vacuum relief valve, inlet filter, control panel and system skid plate. An oil sealed liquid ring system is more tolerant of carryover and wear, and it provides quiet operation. The oil is not required for lubrication which means it can operate at extremely long intervals between oil changes, easily going more than 10,000 hours with no down time. Aside from a periodic oil and filter change, the system can run for years with no scheduled maintenance. If your process requires very deep vacuum, Gardner Denver Nash has the solution. Using a two-stage liquid ring pump in an oil sealed system, vacuum levels lower than 10 Torr (29.6" HgV) can be attained.

Request for a quote

Request for quotes

Create one request and get multiple quotes form verified suppliers.

  • Only relevant suppliers
  • Data privacy compliant
  • 100% free