• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • analysis measurements

Results for

Analysis measurements - Import export

Manufacturer/producer

Turkey

Verified by Europages

Materials - Metallography laboratory includes metallographic sample preparation equipment, 500X optical microscope, grain structure imaging and analysis program, hardness measuring devices.

Request for a quote

Germany

Verified by Europages

The new QuellTech Q5 Laser Scanner Series combines the advantages of small form factors with both high resolution and scan rate. The sensor disposes of different set-up possibilities with respect to the analysis algorithm. Measurement results are delivered via Ethernet, calibrated in the X / Z plane. Special adjustable algorithms can be selected, extremely useful particularly also for optically most demanding surfaces. Time-consuming calibration tasks for the user are no more required, as the calibration routine runs on board. High Scan Rate with up to 14,000 Profiles per Second Due to an appropriate limitation of the image range (AOI) in X and Z direction, the scan rate could considerably be increased. High resolution and detection frequency with up to 14.000 profiles and 28 Mio. points per second •X measuring range from 10 to 1022 mm •Z measuring range (height) from 5 to 878 mm •Laser wave length blue 405/450nm, red 650nm

Request for a quote

Germany

Verified by Europages

Thanks to latest digital technoloy, we can meet your demands at a high professional level. We provide 2D/3D measurement (e.g. dimension measurements, burr measurements, grain size analysis, residual contamination analysis according to ISO 16232 & VDA 19, profile measurements, particle analysis, 3D presentation) with multi-lightning view for various illumination angles, optical shadow effects to clearly identify smallest univenness, reflexion reduction and HDR-view for high colour graduation. Several types of perspectives are possible thanks to a pivoted angle of sight (up to 90°) or by adjusting the mobile object lense (e.g. hollow spaces). We compile a detailed documentation including pictures or videos, where even real-time swivellling views can be recorded. We are looking forward to receiving your enquiry!

Request for a quote

Germany

Verified by Europages

DigiVision offers innovative functions such as practical calibration tools, configurable single-channel or multichannel views for displaying both measurement curves and values, and custom zoom functions. With a choice of trigger functions, every application has a wealth of options for activating data acquisition. Important performance features include automatic device detection, device-parameter backup and archiving of measurement data in Excel or raw data format. In the world of production and quality assurance, coping with an ever increasing variety of software is part of daily life. Operating several different instruments at once is easier if each device can be operated in the same way. All burster indicators and USB sensor interfaces are equipped with the DigiVision PC software. This data-acquisition and configuration software even supports indicator units purchased years ago.

Request for a quote

France

Verified by Europages

Certified multisensor dust monitor – category 1 under ATEX / IECEx – for indicative emissions trending and measurement in hazardous zones and in dry processes with elevated pressures. Advanced probe electrification featuring long term data logging for process trend analysis and reporting. • reliable measurement of leaking and broken bags in dust collectors • sensor configured remotely via controller • automatic sensor drift checks • automatic probe check for improved data integrity • reduces filter maintenance intervals, process downtimes and filter costs

Request for a quote

Germany

Verified by Europages

The dimensionCONTROL TMWI 8302.LC system is suitable for the inline weight inspection of continuous running rubber profiles (tread pattern or sidewalls) for passenger and truck tires. Based on the force measurement principle, the inspection system uses two load cells which measure the deflection of the measurement conveyor. These sensor elements are attached to a massive construction, which ensures a long-term mechanical stability of the system. The measurement conveyor uses precise and balanced aluminum rollers with special surface treatment. This ensures a low deadweight, avoids influence of unbalance and eliminates material sticking. Data obtained from the load cells are processed in the implemented PLC cards which determine the measured weight mathematically.The software included offers a variety of measurement data processing, definition of design profiles, statistical analysis of measured profiles and diagnostic tools.

Request for a quote

France

Verified by Europages

To accompany the Sam3D Lite or Lite+ software, a kit is available for carrying out postural diagnostics in a mobile version. The kit includes: Sam3D LITE image acquisition device Carrying case Sam3D reference ground plate Compact tripod Sam3D LITE / LITE+ analysis software Connection cable Tape measure Marking pen

Request for a quote

Germany

Verified by Europages

China

Verified by Europages

INNOVACERA provides a variety of thermal analysis crucible that can be used as sample containers for thermal analysis measurements. The crucible is used as a container for samples during thermal analysis measurements.They guarantee that the sensor will not be contaminated by the measurement.The type of crucible used for the measurement may have a great influence on the quality of the results obtained, as well as on the important characteristics of the DSC measurement unit.Taking relevant factors into account before making a measurement often saves time in interpreting the curve later. TGA Crucible Features: Large volume – increases the sensitivity Purity – elimiates interaction between the sample and the crucible Material – guarantees high form stability Flatness – ensures perfect thermal contact High temperature resistance- Standard TGA crucible are used up to 1600 °C and are available for different sample volumes.

Request for a quote

Germany

Verified by Europages

We develop and build test stands for pumps and can refer to several references in this field. In addition, we build press-off facilities and design them individually, including suitable risk assessment. Our process visualisation is suitable for customer presentations of the running pumps directly at the pump test stand. In addition, Merecs Engineering provides the connection to the IT infrastructure of our customers (ERP systems or databases). - Planning, calculations and construction - Coordination of suppliers - LabVIEW software development - NI-Real-Time & FPGA for high-speed evaluation of speed and acceleration measurement values - Vibration analysis via FFT (updated live) - LabVIEW, NI-cRIO and Siemens S7-1500 PLC in combination possible - Database connection - On-site assembly and IB

Request for a quote

Turkey

Verified by Europages

DSC for determining the oxidation induction time for polymer pipe and protective pipe systems as well as moulded elements made of polyolefin. Suitable for OIT test and Melting point determination According to ASTM D3895 ISO11357 EN728 ASTM D3418 up to 500C Including standard Tin, Ind pellets for calibration checkout, 400pcs of aluminium pans, Software CD (windows based software including Report out to WORD), N2 and O2 rotameter mass flow controller, Hoses and connectors, Software also has data export to advantage Software for analysis, DSC measuring cell according to the heat flux principle, temperature sensors for control & sample temperature, Connection for Purge gas flow to the sample for 2 gas types, Temperature accuracy 0.1 C, Sensitivity: 3.6 to 4.0 μV/mW , Sensor Time constant: 2.5 s, calorimeter accuracy of ± 2% and calorimetric precision of ± 0.5% or better, Two connections for purge gas-Inlet to the sample & 1 connection for protective gas Inlet with gas flow adjustment,

Request for a quote

Germany

Verified by Europages

ORP sensor for water applications The OPTISENS ORP 8590 sensor is characterised by standardised design, easy handling and a long life cycle. In combination with the MAC 100 signal converter it is possible to create an extremely reliable and low-cost measurement system, which is suitable for a wide range of water analysis measurement tasks. Designed as combined electrodes with built-in reference electrode the OPTISENS ORP 8590 is equipped with a platinum electrode, ceramic diaphragm and integrated temperature sensor Pt100.The sensor can be easily adapted to various application requirements and it is extremely service friendly and durable.

Request for a quote

Germany

Verified by Europages

Inductive conductivity sensor for water Analysis The inductive conductivity sensors of the OPTISENS IND 1000 feature a compact and extremely rugged design as well as a wide measuring range. In combination with the MAC 100 signal converter it is possible to create an extremely reliable and low-cost measurement system, which is suitable for a wide range of water analysis measurement tasks. These systems are very well suited for conductivity measurements in severely contaminated, aggressive media in the water and wastewater industries. - Compact design for pipelines with small diameters - Wide measuring range (0.5…2000 mS/cm) - Corrosion-resistant and dirtrepellent material PP or PVDF - Completely enclosed measuring cell with two inner, ring-shaped measuring coils - Integrated temperature sensor

Request for a quote

Germany

Verified by Europages

Free chlorine/chlorine dioxide/ozone measuring system for water applications The OPTISYS CL 1100 measuring system consists of the membrane free OPTISENS CL 1100 sensor. The sensor is characterised by standardised design, easy handling and a long life cycle. Together with the MAC 100 converter, flow-through holders, valves, temperature sensor and an optional pH sensor OPTISENS PH 8500, this is a tested and ready to use measuring system which is very reliable and easy to maintain. The system is suitable for a wide range of water analysis measurement tasks. - Complete measuring system – ready to use and easy maintenance - High quality and precise gold electrodes for usage in water analysis - Membrane-free sensor for a wide application range

Request for a quote

Germany

Verified by Europages

pH sensor for water applications The OPTISENS PH 8100 sensor is characterised by standardised design, easy handling and a long life cycle. In combination with the MAC 100 signal converter it is possible to create an extremely reliable and low-cost measurement system, which is suitable for a wide range of water analysis measurement tasks. Designed as combined electrodes with built-in reference electrode the OPTISENS PH 8100 sensor type is equipped with two open diaphragms and integrated temperature sensor Pt100. The sensor can be easily adapted to various application requirements and it is extremely service friendly and durable.

Request for a quote

Turkey

Verified by Europages

Acoustic Testing Cabins are specialized enclosures designed for conducting precise evaluations of soundproofing and acoustic performance. These cabins provide controlled environments for testing materials, components, and products under various noise conditions. Equipped with advanced sound measurement instruments and analysis tools, these cabins facilitate comprehensive acoustic testing. They allow for the assessment of sound absorption, transmission loss, reverberation time, and other key parameters crucial for evaluating noise reduction capabilities. Acoustic Testing Cabins feature customizable configurations to accommodate different testing requirements and sample sizes. They offer flexibility in testing methodologies and ensure accurate and reliable results.

Request for a quote

Germany

Verified by Europages

The award winning MATRIX-F II FT-NIR spectrometer allows the direct measurement in process reactors and pipelines, leading to a better understanding and control of the process. Accurate in-line results in seconds Multiple components per measurement Non-destructive analysis Optional built-in 6-port multiplexer Direct method transfer Rugged design Ethernet connectivity and industry standard communication protocols

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Turkey

ISONEM ANTI SOUND PAINT, the acoustic paint which is used to stop and reduce sounds, is designed to absorb and isolate the sound in the best possible way. According to the measurement and analysis carried out in conformity with the TS 140-s Standart; It has been certified in Türkak approved accrediting laboratoires, that the applied paint reduces and absorbs the sound level 2,51 dB as regards to 1000Hz, when applied as a 1 mm thick layer and it reduces and absorbs the sound level 4,85 dB as regards to 1000Hz, when applied as a 2mm thick layer, in the 1/3 octave frequency band. The paint is water based. It can be manufactured in any color specified. In addition to its sound isolation properties, it is resistant to fires whit its delayed flammability and non-flammability properties. It is suitable for using to reduce sound levels in any place with sound level problems. PLACES OF USE: • Apartments, • Engine and Machine Rooms, • Disco and entertainment venues, • Cinemas and theatres

Request for a quote

Liechtenstein, Principality of

RF Sensor with FabGuard Provides Real-time Plasma Process Analysis to Significantly Reduce Process Variability INFICON RF sensor technology provides highly accurate, broadband, frequency discriminant RF measurement for semiconductor processing tools. This RF data provides detailed insight on actual plasma conditions of both process development and production process problems to significantly reduce process variability. The latest in its suite of advanced process control in situ sensors, this non-intrusive in-line cable mount RF sensor combines with FabGuard Sensor Integration and Analysis Systemto offer critical diagnostic information, e.g. accurate chamber and process power and impedance measurement, root cause analysis of faults (such as matching network problems), process fingerprinting for chamber matching, and wafer metrology modeling in PVD, CVD and etch applications. INFICON RF sensor technology with FabGuard generates highly accurate models that predict wafer metrology...

Request for a quote

United Kingdom

The ZWR+ is 5 times more productive than any standard measurement of SF6 gas purity in gas insulated switchgear and high voltage equipment. Delivering laboratory-standard accuracy, stability and repeatability in the field: the ZWR+ provides automatic, multi-analysis gas quality testing using advanced IR measurement technology for the fastest and simplest, zero-emission measurement solution in GIS preventative maintenance.

Request for a quote

Russia

Diagnostic complex Dianel®Micro specal software “Dianel® micro” that compatible with most of all the digital microscope cameras. DianelMicro software is intended to visualize an image with a high resolution on the screen, automation of qualitative sample examination of any micro objects and bio materials, storage, measurement, analysis and systematization of photo images and video. DianelMicro software Benefits Compatibility with any models of microscopes and digital cameras; An image output with Magnification up to 8000x (Depends on camera and optical adapter); Clear HD video quality; Full Screen with full resolution sharp live video and samples preview; Making Foto of Samples and Video files of dinamically changing micro objects; Card files for million examinations; Reasonable price. Free two-mounts trial available; Freee support and software updates

Request for a quote

Slovenia

IMCS is a sophisticated multi-sensor measurement, data collection, analysis and alerting system. IMCS is extremely versatile due to its open and modular architecture, enabling a diverse set of applications. It can equally well be used on the factory floor monitoring production line performance, in a greenhouse continuously monitoring environmental conditions and effecting measures for ensuring optimal growth conditions, or for capacity monitoring within electrical distribution grid nodes.

Request for a quote

Germany

- Quality control and safeguarding - Individual test values and criteria - Customer-specific measuring and testing plants - Single measuring systems with manual assembly - Fully integrated and automated testing plants using robots - Optical, acoustic or electrical systems with/ without parts contact, data preparation, analysis Measuring and testing systems we were involved in: - Camera systems with corresponding image processing - Part recognition, positioning, color and surface examination, checking for damages - Optical / tactile / ultrasonic tests using sensors and displacement measurement systems - Leakage and pressure tests - Inspection and monitoring of filling level - Run-out properties and accuracy - Backlash measurement - Electrical tests and measurements - Electrical values, check measurements, switching and opening properties Used in all branches: e.g. pharmaceuticals industry, medical engineering, cosmetics, electronics and automotive industries.

Request for a quote

Germany

High-quality laboratory microscope with integral 2 megapixel CCD colour camera: We use this type of microscope every day in our production and quality assurance departments, so we can also recommend it to our customers. Special features of the microscope Camera resolution max. 1600 x 1200 pixels – also suitable for video recording. Complete with USB 2.0 PCI card for fast data transmission Including image analysis software for evaluation, measurement, and archiving with a PC (Win 2000/XP) With calibrating scale 4 top-quality objective lenses: 4x, 10x, 40x, 100x 30 W halogen lamp with iris diaphragm and colour filters Cross-table with object slide Holder Variable-height and adjustable condenser Fine adjustment for precise focussing Quality transmitted light microscope for laboratories with integrated 3 megapixel CCD color-camera

Request for a quote

Switzerland

The APLUS is a powerful platform for measuring, monitoring and analyzing power systems. The focus is on highest Swiss quality and maximum customer benefit. This universal measurement device is available in three major versions: With TFT or LED display or in top hat-rail version without display. It can be easily integrated into the process environment on site. It provides a wide functionality, which may be further extended by means of optional components. The connection of the process environment may be performed by means of the communication interface, via digital I/Os or via analog outputs.

Request for a quote

Germany

This 2 channel premium pyrodetector offers an optimal performance for the measurement of carbon compounds (CxHy) through the narrowband infrared filter with a CWL of 3400 ± 20 nm and a HBW of 140 ± 20 nm as well as an additional reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm). The particularly high detectivity of up to 4.0*10^8 cm√Hz/W as well as the very high sensitivity of up to 200000 V/W guarantee precise and long-term stable measurement results. The pyroelectric detector allows demanding applications in gas measurement and gas analysis in various industries such as aerospace, medical or industrial process technology. Two detector chips with a ceramic pyroelectric thin film diaphragm form the core of this 2 channel pyroelectric detector. The low microphone effect due to the low membrane mass, the very low temperature dependence and an amplified signal in current modes enhance the measurement signals of the dual IR detector.

Request for a quote

Germany

The narrow-band filter of the MTS2SENS200 carbon dioxide with a CWL of 4265 ± 25 nm and an HBW of 120 ± 10 nm is optimized for the measurement of carbon dioxide (CO2) with reference channel (CWL: 3910 ± 28, HBW: 70 ± 10 nm). The detector is characterized by an integrated thermistor for reference temperature determination and an interference absorber. They both ensure that the signal is converted as efficiently as possible from radiant energy to thermal energy. The basis of the IR thermopile MTS2SENS200 carbon dioxide are 2 chips with 200 bismuth-antimony/antimony thermocouples each. Thanks to them and the filling with krypton, the detector convinces with a detectivity of up to 6.27*10^8 cm√Hz/W and sensitivity of up to 171 V/W. The signal quality is comparable to pyroelectric detectors. The detector can be used at ambient temperatures between -20 and 85 °C in numerous industrial, aerospace and medical applications: Exhaust gas measurement, breath gas analysis or patient monitoring.

Request for a quote

Germany

The cost-efficient infrared emitter JSIR340-4 is optimized for NDIR gas analysis and other infrared measurement applications such as DIR spectroscopy, ATR spectroscopy or PAS spectroscopy. The membrane of the cmOS based IR emitter reaches membrane temperatures of up to 800 °C. It provides long-term stable radiation output for industrial applications for control and monitoring of process gases, associated gases at ambient temperatures between -20 and 85 °C. The packaging version in the standard TO housing with cap is suitable for measuring distances up to 2 cm. The MEMS chip used in our IR emitters consists of a multilayer hot plate diaphragm containing a high temperature stable metal C-MOSI layer. The emitter chip has an active area of 2.2 x 2.2 mm2 and is based on a silicon substrate with a back-etched membrane. All thin film processes are performed using standard MEMS processes and cmOS compatible materials. The active C-MOSI resistive layer is protected against aging & environment.

Request for a quote

Germany

Cost efficient infrared emitter for NDIR gas analysis and other infrared measurement applications. With only 250 mW required input power, the emitter is also suitable for mobile - and handheld devices. The membrane of this cmOS based ire source achieves membrane temperatures up to 800 °C with long term stable radiation power and short time constant. For high volume applications such as building air conditioning, automation and others, the JSIR 340 is suitable due to its excellent price/performance ratio. The packaging with reflector is good for measurement distances from 2 cm. The MEMS emitter chip consists of a multilayer hotplate membrane containing a high temperature stable metal C-MOSI layer. The emitter chip is based on a silicon substrate with a back-etched membrane. All thin film processes are performed with standard MEMS processes and cmOS compatible materials. The active C-MOSI resistor layer is protected against aging and environment.

Request for a quote

Request for quotes

Create one request and get multiple quotes form verified suppliers.

  • Only relevant suppliers
  • Data privacy compliant
  • 100% free