2-phase high-torque stepper motor in NEMA 17, NEMA 23 and NEMA 34 sizes with flat-milled shaft (D-shaft). 1.8ׄ° increment angle (full increment) with integrated positioning control. Note: Stepper motor with integrated positioning control. It forms a convenient unit consisting of stepper motor and intelligent controller. Reference travel is possible on a block with reduced electric current without proximity switch. Integrated rotational monitoring. Smooth running through dynamic switching of increment trip. Actuation via single I/O interface, 31 position configurations and call-ups. Control unit can be parametrised quickly and conveniently with the software. The software and manual for programming the positioning control are available as free download. When selecting a suitable motor, using just the retaining torque is not enough, as the motor’s torque decreases with the speed. It is therefore essential to select the correct motor according to the torque curve.

Request for a quote

France

Verified by Europages

Base and rotary table aluminium alloy. Hollow shaft stainless steel. Preloaded worm gear steel. Claw coupling aluminium with polyurethane coupling spider. Version Aluminium alloy anodised. Note for ordering The unit is supplied with the position of cable outlet or control unit as shown in the drawing. Note Rotary positioning stages for motorised adjustment and positioning tasks. The preloaded worm gear runs virtually playfree. The bearing of the worm shaft offers maximum radial rotational accuracy. Cables can be routed through the large bore in the hollow shaft. The adjustable positioning ring is used to determine the rotational reference point to the position of the assembled part. Proximity switches can be mounted with the optionally available sensor holder (21094). The suitable programming software and interface cable for the stepper motor with positioning control are available as accessories (2500015).

Request for a quote

France

Verified by Europages

Bearing block and carriage aluminium alloy. Guide column and threaded spindle stainless steel. Plain bearing for guide columns and spindle nut highquality special plastic. Claw coupling aluminium with polyurethane coupling spider. Version Aluminium alloy anodised. Stainless steel hardened and ground. Threaded spindle with ball bearing. Note for ordering The unit is supplied with the position of cable outlet or control unit as shown in the drawing. Note Positioning stages for motorised adjustment and positioning tasks. The plain bearings and spindle nuts are suitable for dry running, however lubrication with a grease for plastic plain bearings is recommended. The suitable programming software and interface cable for the stepper motor with positioning control are available as accessories (2500015).

Request for a quote

France

Verified by Europages

Pneumatic clamps have the following advantages compared to hand clamps: The operator is relieved of frequent clamping. Several clamps can be activated at the same time and can be closed in a specific sequence. Single or multiple clamps can be activated from varying positions by machine control or hand control. Because of the toggle system: the clamp remains closed if the air supply fails. the air consumption is low due to the large end ratio. pivoting the clamping arm achieves a large opening travel. optimum force and movement ratios are achieved. VL = air consumption per complete cycle in dm³ at 6 bar. Selection criteria: To select the correct size of pneumatic clamps, the possible clamping force at 6 bar (any compressed media are permissible, maximum pressure 10 bar) is specified besides the retaining force. F3 is the possible clamping force that the clamp exerts on the end of the clamping arm, F4 the force it exerts on the fulcrum side.

Request for a quote

France

Verified by Europages

EASY-TO-USE Custom engraving has never been easier. Forget about endless technical trainings, the M20 rotary engraving machine could not be simpler to use: intuitive control panel, multiple positioning vices, open design for easy part loading and unloading… The M20 also offers a Bluetooth option. GRAVOTECH UNIQUE ENGRAVING ASSISTANCE FEATURES The M20 comes with numerous features to simplify your engravings. The Point & Shoot function suppresses the risk of error by surrounding the engraving area. The rotary engraver automatic height adjustment, combined with depth nose that tracks the surface during the engraving, ensures a clean and constant result without wasting time in technical settings. PERSONALIZATION MACHINE THAT CAN BE PERSONALIZED The M20 is the ideal solution for gift engraving (pens, key rings, perfume engraving) and photos or logos engraving on medals, lighters and more. Moreover, this desktop engraving machine can easily be customized to evolve with your business.

Request for a quote

France

Using the pressure and temperature, the stripes are applied to the overlay or the sheet, while the protective film is removed and wound on a support. The machine can be equipped with a guillotine for cutting formats, or (and) a reel for the overlay after removing the piste. The machine can also be equipped with two systems to work on leaves and on roll. Unwinder roll overlays on mandrel Side guides adjustable micrometer Winding device holder with the magnetic track in the event detection cell decasse. Mounting Tape with voltage control, and adjustable positioning guides the rollers. Positioning + or 0.1 mm servo motor 0,75 KW Cleaning system with a double face support roller on the output Storage formats tracked on a table with two anti static set before laguillotine and before the table or rewound Touch screen control friendly, multi lingual (French and / or English), setting and trimming various counts Use of electrical

Request for a quote

France

Removing the roller tracks by independent heating up to 220 ° C Adjustable speed of laying tracks up to 5 m / min Manual loading of sheets Side guides adjustable micrometer Winding device holder with the magnetic track detection cell in case of breakage. Mounting Tape with voltage control, and adjustable positioning guides the rollers. Positioning + or 0.1 mm servo motor 0,75 KW Cleaning system with a double face support roller on the output Storage formats tracked on a table with two anti static positioned before the guillotine and before the table Touch screen control friendly, multi lingual (French and / or English), setting and trimming various counts Use of electrical, hydraulic and pneumatic standardized Safety guards for strict compliance with CE OPTIONS MTL 700 NSA automatic loading of sheets Roller and additional heating system for a different bandwidth

Request for a quote

France

Discover MECAJET the new range of Water Jet equipments conceived by MECANUMERIC, machining and cutting by VHP soft materials, and, with addition of abrasive, hard materials. Refer to the exemples of applications : Precision engineering technical parts Electric vehicles parts Parts for subways Parts for trams Bus parts Trolleys Household appliances Lights Furniture Weather vanes Discover the new range of very high pressure Waterjet equipment MECAJET designed and manufactured by MECANUMERIC, for cutting of several materials: * Soft materials: - rubber - plastics - leathers... * And, with addition of abrasive, hard materials: - metal - ceramic - glass - stone - composite materials... The MECAJET integrate the last novelties: driving system on POWER AUTOMATION numerical control (CN7100 ISO), new long-lasting pneumatic cutting heads, axes positioning control, 3 or 5 axes head, clearance control, etc... The cutting table is equipped with a steel welded one-block frame with...

Request for a quote

France

RFID sensor with 16 million codes Suitable for metallic environments Programmable code through auto-learning (no software or PC) Level of performance with AWAX controller: up to PL = e Safety category: up to 4 (EN 954-1) with AWAX controller Time to dangerous failure: MTTFd = 40 years Max activation distance: up to 24 mm Security contact/diagnostics: 2 x redundant NO 50mA/30V and 1 x 50mA auxiliary PNP Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 50cm PUR cable with M12 connector Sealing: IP 67 Standing room temperature: -30 °C to +50 °C. Storage temperature: -40 °C to +85 °C Marking: pad printing + serial number for traceability Certificate: E2 10R-04 14053 (UTAC) ISO 7637-2 (Pulse 1, 2a, 2b, 3a, 3b, 4)

Request for a quote

France

40N integrated stainless steel magnetic door holding Contactless coded electronic sensor Total safety management with an AWAX controller Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 360 years Max. activation distance: 3 mm, 2 mm hysteresis Holding Force: transmitter + receiver in contact = 40N Safety contacts/diagnostics: 2 x NO 0.8A max / 48V redundant and 1 x PNP 250mA Detection encoding: mono-code inviolable Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 1 Material: INOX 316L mirror polished Electrical Connection: 3, 6, 12m cable or 50cm cord PUR M12 (ref. + MKT) Water resistance: IP 67/68 (EPINUS-4K-MKT) and IP 69K (EPINUS-4K/SES) Temperature: -25°C to +70°C. Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

High temperature, magnetic door holding, integrated 20N Contactless coded electronic sensor Total safety management with an AWAX controller Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 3 mm, 1 mm hysteresis Holding Force: transmitter + receiver in contact = 20N Safety contacts/diagnostics: 2 x NO 0.8A/24V redundant and 1 x PNP 250mA Detection encoding: mono-code inviolable Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Extreme temperature: -40°C to +125°C Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

Manages person entry in hazard zones using an electrical locking key Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Electrical locking key with position contact Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 2xPNP 250mA auxiliary (open/closed door and locking/unlocking of contacts) Detection encoding: mono-code inviolable Note: two-color LED indicates the key locking position; white LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: Polycarbonate Electrical connection: M12 metal base Water resistance: IP 65 Temperature: -15°C to +60°C Marking: screen printed + serial no. for traceability

Request for a quote

France

Contactless encoded electronic sensor with relay Up to 8 zone differentiation codes Safety contacts 2A / 250V • Level of performance without an external controller: PL = c • Level of performance with AWAX controller: up to PL = e • Safety category without an external controller: 1 • Cycle before dangerous failure: B10d = 2,000,000 at 2A • Max. activation distance 3SSR24V/5SSR24BX/5SSR24BX-US: 8 mm, 2 mm hysteresis • Max. activation distance 2SSR24V/2SSR24BX: 4 mm, 2 mm hysteresis • Safety contacts/diagnostics 3SSR24V: 1 x NO 2A/250V / 1 x NF 2A/250V auxiliary • Security contacts/diagnostics 5SSR24BX and 5SSR24BX-US: 2 x NO 2A/250V / 1 x PNP NF 250mA auxiliary (24V) • Security contacts 2SSR24V: 2 x NO 2A/250V • Security contacts 2SSR24BX: 1 x NO 2A/250V and 1 x NF 2A/250V • Detection encoding 3SSR24V, 5SSR24BX/5SSR24BX-US: single inviolable code • Detection encoding 2SSR24V and 2SSR24BX: 8 inviolable codes • Indicators 2SSR24V, 2SSR24BX, 3SSR24V and 5SSR24BX: Red LED indicating code absence (not transmitter) • Indicator 5SSR24BX-US: Two-color red/green LED • Reset: automatic • Attachment: 4 tamper-proof M4 screws (optional ref: BH4) • Mounting position: 2 (double wall brackets) • Matierial PA6: 2SSR24V, 2SSR24BX, 3SSR24V, 5SSR24BX, 5SSR24BX-MKT and 5SSR24BX-US • Material INOX 316L mirror polished: 5SSR24BX-OX and 5SSR24BX-OX-MKT • Electrical Connection: 3, 6, 12m cable or 50cm cord with M12 connector (UL20549 PUR) for5SSR24BX-OX and 5SSR24BX-OX-MKT • Water resistance: IP 67/68 (PA6) or IP 69Kwith stainless steel - new generation • Temperature: -25°C to +60°C • Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller High temperature Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 1A/24V redundant and 1 x 250mA PNP contact Detection encoding: mono-code inviolable Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Extreme temperature: -40°C to +125°C Protective cover 316L stainless steel mirror polished "ref. + C" option Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

Contactless coded electronic sensor Connectors / Wiring compatible with most hardware Suitable for grooved profiles Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 8 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.8A/24V redundant and 1 x 250mA PNP contact Detection encoding: mono-code inviolable Indicator: 1 LED indicating code recognition and 1 LED indicating code absence Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4). Suitable for grooved profiles. Screw caps provided. Mounting position: 1 Material: INOX 316L mirror polished Electrical connection: 2 x 50cm cords with M12 connector Water resistance: IP 69K Temperature: -30°C to +70°C. Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

20 N integrated handle magnetic door holding High temperature and silicone cable Contactless coded electronic sensor Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 3 mm, 1 mm hysteresis Holding Force: transmitter + receiver in contact = 20N Safety contacts/diagnostics: 2 x NO 0.8A/24V redundant and 1 x PNP 250mA Detection encoding: mono-code inviolable Reset: automatic Housing mount: 4 tamper-proof M4 screws (optional ref: BH4) Handle assembly: M8 screw (optional handle) Mounting position: 2 (double wall brackets) Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Extreme temperature: -40°C to +125°C Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller High temperature Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 7 mm, 1 mm hysteresis, rotation ± 30° Safety contacts/diagnostics: 2 x NO 1A max/24V redundant and 1 x PNP 1A auxiliary Detection encoding: mono-code inviolable Reset: automatic Attachment: 2 central M4 screws not included; anti-rotation lugs provided Mounting position: 1 Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Operating temperature: -30°C to +110°C. Peak temperature: -40°C to +130°C Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Contactless coded electronic sensor Total safety management with an AWAX controller Suitable for groove profiles and single or double doors Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 334 years Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.8A max/24V redundant / 1xNF (78S) or 1 x NO (98S) 250mA Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4). Suitable for grooved profiles. Screw caps provided. Mounting position: 1 Material: Polycarbonate Electrical connection: 2 M12 metal bases for instant serial connection Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: screen printed + serial no. for traceability

Request for a quote

France

Sensor contactless technology, low simultaneity ATEX Zone 2 and 22 category 3GD No power Atex safety EN 60079-15 EN 61241-1 Machine Safety Level of performance with AWAX26XXL-EEX3 controller: up to PL = e in accordance with EN ISO 13849-1 Cycle before dangerous failure: B10d = 62,500 Max. activation distance: 17 mm, 5 mm hysteresis Safety contacts/diagnostics: NO 2 x 50 mA/24V redundant 1xNF/50mA/24V redundant parallel Overcurrent: 500mA for 2s Shock resistance: 50 G. Vibrations: 30 G Detection encoding: mono-code Indicators: no Reset: automatic Total number of connectable sensors in series: 30 Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Marking: pad printing + serial no. for traceability Electrical connection: 3, 6, 12m cable Water resistance: IP 67 Temperature: -5°C to +80°C.

Request for a quote

France

Contactless coded electronic sensor ATEX zone 0/20 (PL version) or 1/21 (OX version) Atex safety ATEX standards EN 60079-0 EN 60079-11 EN 60079-25 EN 60079-26 ATEX marking for PL version II 1 GD Ex ia IIC T4 Ga Ex ia IIIC T135°C Da Product used in combination with AWAX26XXL-EEX box ATEX marking for OX version II 2 GD Ex ia IIC T4 Gb Ex ia IIIC T135°C Db Product used in combination with AWAX26XXL-EEX box Machine Safety Level of performance with AWAX controller: up to PL = e Safety category: 4 with AWAX controller Time before dangerous failure: MTTFd = 277 years Max. activation distance: 10 mm, 4 mm hysteresis Safety contacts/diagnostics: NO 2 x 50 mA/12V redundant and 1 x PNP 15mA/12V contact Shock / vibrations: 30 G Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Total number of connectable sensors in series: 0 Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 (PL version) or INOX 316L mirror polished (OX version) Electrical connection: 12m or more on request Water resistance: IP 67

Request for a quote

France

40N integrated stainless steel magnetic door holding Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 4 mm, 2 mm hysteresis Holding Force: transmitter + receiver in contact = 40N Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 1 x PNP 250mA encoding detection: single inviolable code Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 1 Material: INOX 316L mirror polished Electrical connection: 3, 6, 12m cable Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: INOX316L laser engraving with mechanical punching of the serial number for permanent traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Low cost solution for multi-access applications Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 420 years Max. activation distance: 9 mm, 1 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.4A max / 24V redundant and 1 x 250mA PNP contact Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 or INOX 316L mirror polished (ref. + OX) Electrical Connection: 3, 6, 12m cable (UL2464 PVC) or 50cm cord with M12 connector (UL20549 PUR) (ref. + MKT) Water resistance: IP 67/68 or IP 69K stainless steel version (requires cable input protection) Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Low cost solution for multi-access applications • Level of performance with AWAX controller: up to PL = e • Safety category: up to 4 with an AWAX controller • Time before dangerous failure: MTTFd = 334 years • Max. activation distance: 10 mm, 2 mm hysteresis • Safety contacts/diagnostics: 2 x NO 0.8A max / redundant 24V / 1xcontact PNP 250mA • Detection encoding: mono-code inviolable • Indicator: LED indicates code recognition • Reset: automatic • Attachment: 4 tamper-proof M4 screws (optional ref: BH4) • Mounting position: 78S-98S, 78SMKT, 78SMKT130 versions: 2 (double wall brackets) • Mounting position: 78SM12 and 98SM12 versions: 1 • Material: 78S-98S, 78SMKT, 78SMKT130: PA6 or INOX316L (ANATOM78S-OX or ANATOM78S-OX-MKT) • Matierial for 78SM12, 78SESM12 and 98SM12 : polycarbonate (PC) • Electrical Connection: 3, 6, 12m cable (78S/98S) or 50cm cord with M12 connector (ref. + MKT) or 130cm cord with M12 connector (ref. + MKT130) or M12 metal (ref. + M12) • Water resistance: IP 67/68 (PA6, PC) or IP 69K with stainless steel - new generation • Temperature: -25°C to +60°C • Marking: PA6 pad printing + serial no., PC pad printing + serial no., INOX316L laser engraving with mechanically punched serial no. for permanent traceability • Certification: UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209) (Not applicable for versions MKT and M12)

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 50mA Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts: 2 x NO 250 mA/48V redundant Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) Water resistance: IP 67/68 Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Suitable for groove profiles and single or double doors Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 8 mm, 3 mm hysteresis Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 1 x PNP 250mA (X5) or 1xNF (X5.2) auxiliary Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic (SR version) or Manual (AR version) Attachment: 4 tamper-proof M4 screws (optional ref: BH4). Suitable for grooved profiles. Screw caps provided. Mounting position: 1 Material: Polycarbonate Electrical connection: 1 M12 connector (X5 version) or 2 M12 connectors (X5.2 version for instant serial connection) Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: screen printed + serial no. for traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle after dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 10 mm, 2 mm hysteresis Security contacts / diagnostics AMX5 / AMX5CM12: 2 x NO 2A / 48V redundant / 1 x PNP 250mA auxiliary Security contacts AMX4: 2 x NO 2A/48V redundant Security contacts / diagnostics AMX3: 1xNO 2A / 48V redundant (2 series contacts) / 1xNF 250mA auxiliary Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 or INOX 316L mirror polished (AMX3-OX/AMX5-OX ⇥or PC (AMX5CM12) Electrical Connection: 3, 6, 12m (UL2464 PVC) or 50cm cable with M12 connector (UL20549 PUR) (ref + MKT) or M12 metal base (AMX5CM12) Water resistance: IP 67/68 (PA6 / PC) or IP 69K with stainless steel - new generation Temperature: -25°C to +60°C Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12 UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209)

Request for a quote

France

RFID sensor with 16 million codes Category 3 total security management without an external controller Programmable code through auto-learning (no software or PC) Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 (EN 954-1) Cycle after dangerous failure: B10d = 2000000 at 2 Amps Max activation distance: up to 24 mm Security contact/diagnostics: 2 x redundant NO 2A/48V and 1 x 400mA PNP auxiliary Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) or 50cm PUR cable with M12 connector (base + MKT) Sealing: IP 67 Temperature: -20 °C to +60 °C Marking: pad printing + serial number for traceability

Request for a quote

France

RFID sensor with 16 million codes Suitable for metallic environments Programmable code through auto-learning (no software or PC) Max activation distance: up to 24 mm Security contact/diagnostics: 2 x 400mA and 1 x 200mA auxiliary PNP Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 50cm PUR cable with M12 connector Sealing: IP 67 Standing room temperature: -25 °C to +70 °C. Storage temperature: -40 °C to +85 °C Marking: pad printing + serial number for traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Cylindrical M18 for "invisible" assembly Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 6 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.8A max/24V redundant / 1xcontact PNP 250mA Detection encoding: mono-code inviolable Reset: automatic Attachment: 2 M30 nuts provided Mounting position: 1 Material: CuNi Electrical connection: M12 metal base Water resistance: IP 67 Temperature: -20°C to +60°C Marking: label + serial no. for traceability

Request for a quote