Position control on ATEX doors / casings

RDX8

Description

Sensor contactless technology, low simultaneity ATEX Zone 2 and 22 category 3GD No power Atex safety EN 60079-15 EN 61241-1 Machine Safety Level of performance with AWAX26XXL-EEX3 controller: up to PL = e in accordance with EN ISO 13849-1 Cycle before dangerous failure: B10d = 62,500 Max. activation distance: 17 mm, 5 mm hysteresis Safety contacts/diagnostics: NO 2 x 50 mA/24V redundant 1xNF/50mA/24V redundant parallel Overcurrent: 500mA for 2s Shock resistance: 50 G. Vibrations: 30 G Detection encoding: mono-code Indicators: no Reset: automatic Total number of connectable sensors in series: 30 Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Marking: pad printing + serial no. for traceability Electrical connection: 3, 6, 12m cable Water resistance: IP 67 Temperature: -5°C to +80°C.