Switzerland, Ebnat-Kappel
...The TSic 306/303/301 Series of temperature sensor ICs is specifically designed as a low-power solution for temperature measurement in building automation, industrial and mobile applications. With a standard calibration and an accuracy of ±0.3 K in a temperature range of 80 K (e.g. +10 °C to +90 °C), the TSic sensors are more accurate than a class F0.3 (IEC 60751) platinum sensor in the range of...
... due to permanent deformation of the sensor element. Measuring ranges: 0 … 1 N / 0 … 2 N / 0 … 5 N / 0 … 10 N / 0 … 20 N Force direction: Tensile and compressive Standardization: Optional Output signal: 1 mV/V Protection class: IP20 Overload protection: Yes Operating temperature range: -20 ... +80 °C Special features: Small dimensions Special features: Easy installation Special features: Special designs available upon request Special features: Burster TEDS optionally available...
Switzerland, Wittenbach
... Detector AGS Relay preliminary alarm/alarm:below 2 A at 30 VDC or 250 VAC, SPDT Detector AGS Analog output signal:4 - 20 mA Sensor Material box:plastic (IP54) Sensor Gas entry:diffusion Sensor Measuring range:0 - 5 Vol. % CO2 (0 - 50.000 ppm) Sensor Accuracy:0.1 Vol. % CO 2 (+ - 100 ppm or + - 5%) Sensor Operating temperature:0 to +50 ° C Detector AGP Alarm settings:3 thresholds Detector AGP Alarm...
Spain, Barakaldo
...The Temperature Probe MB10 is a versatile thermocouple sensor designed for precise temperature measurement in industrial applications. It features a removable interior with a spring load, allowing for easy sensor exchange and calibration. The MB10 probe is constructed with a metal sheath, ensuring durability and resistance to harsh conditions. This makes it an ideal choice for industries such as...
Switzerland, Winterthur
...The pressure transducers of the 6L series have a small and compact design, making them ideally suited to OEM applications with limited installation space. The metal diaphragm is welded on front-flush and gap-free, separating off the piezoresistive pressure sensor, which is made of silicon, from the measuring medium. Every pressure transducer is measured over the entire pressure and temperature profile and is supplied with a detailed calibration sheet. Pressure Ranges:0…10 to 0…200 bar Accuracy:±0,5 %FS Long Term Stability:±0,35 %FS Dimensions:⌀ 13 mm x 4,5 mm Temperature Range:-10…80 °C...
... response time of the thermocouple is desired Not protected against furnace atmospheres or electrical interference Type N, 2mm ⌀ mineral-insulated for uniformity tests (TUS) according to AMS 2750D Calibration according to AMS 2750 and CQI-9 Less susceptible to oxidation, may be reused multiple times Type K, fiberglass-insulated high-temperature probes for windshield production Used with mounting kit...
Germany, Donaueschingen
...The B+B measuring transducer module Pt1000 with voltage output 0-10V, is an accurate reliable digital measuring transducer in a miniaturised PCB design with modern ASIC technology - digitally calibrated for connecting Pt1000 sensors. Name:Measuring transducer module with customer-specific calibration Temperature measuring range:Selectable between -200...+650 °C Sensor:Platinum sensor Pt1000...
Switzerland, Rossens
... range of temperatures and pressures, even in the most extreme applications. The DI sensor produces a direct output signal of 4 to 20 mA corresponding to the measurement range, as well as a temperature output in VDC. An optional Magtrol signal converter of type CST 113 is available, allowing for the calibration of the measurement chain according to specific needs for current or voltage output. Wide...
Germany, Hamburg
... resistance - IP68, IP69K - Suitable for Smart Calibration - intelligent calibration without the use of mass standards - Optional version with dual measuring bridge available - Ex versions available - Optional version with an extended operating temperature range up to 150°C - Accuracy class L (0.5%) and N (0.06%) - When combined with selected mounting kits, certified according to EN 1090...
France, Huningue
...100% Compliance, 0% Effort Compact Hygienic RTD Temperature Sensor The award-winning smart temperature sensor with integrated HART® transmitter and Heartbeat technology features the world's first resistance thermometer capable of fully automated in-situ self-calibration. It effectively eliminates the risk of undetected non-conformities, reduces production downtime, and enhances product safety and...
... Analog output:± 0.25 % FS Drift vs Ambiant Temperature Analog output:± 0.25 % FS Sensitivity:Linear (See calibration table) mV/°C Sampling frequency:5 Hz Supply Voltage:5–16 V or 12–33 V Supply Current:3 mA Output Voltage:0–5 V or 0–10 V Output Impedance:47 Ω Digital output:ASCII @ 5hz, 9600 Bauds Calibrator:Fluke 714 Dimension “P” type:35 x 20 x 10 mm Material “P” type:Plastic Dimension “A” type:32.5 x 19 x 10 mm Material “A” type:Aluminium Weight:15 g Protection:IP53 Vibration test:20Gpp5’ Shock:500 G Operating Temp:-40 to +125 °C Storage Temp:-40 to +125 °C...
Germany, Mainz
... on highly stable, piezoresistive pressure measuring cells, which are mounted together with an ASIC on a ceramic substrate. The sensors are compatible with the SM5852 as their successor and feature a more modern ASIC for improved temperature compensation and calibration.
Netherlands, Breda
...The new generation of temperature data loggers is on the market: the Emerson TXi Labels temperature data loggers. Emerson TXi Labels utilizes the latest and most innovative temperature sensor. This sensor does not require calibration, ensuring accuracy is maintained. The Emerson TXi Labels temperature data logger is designed for monitoring temperature during the transport and storage of cargo...
...EGE amplifiers process the signals of the EGE filling level sensors for extreme temperatures at a safe distance and are used to set up the sensor via intuitive operation using potentiometer and LED strip. Amplifiers for EGE high temperature limit switches feature an auto-calibration of the switching point at the press of a button. EGE amplifiers provide switching signals or analogue signals, dependent on the device.
Germany, Ortenburg
...The capaNCDT DT61x4 is an active, capacitive system for displacement, distance and position measurements. Consisting of a sensor with integrated preamplifier, a robust cable and a compact controller, the measuring system is immediately ready for use without any on-site calibration. The measuring system is available with a cable length up to 15 m and is ideal for automation purposes. The capaNCDT...
France, Poissy
... • measurement of raw and purified flue gas for desulfurization • measurement of wet and corrosive samples • no nitrogen required for calibration • QAL1 certified analyzer • remote access for all analyzer functions • low maintenance and low consumables requirement...
Germany, Seligenstadt
...— Residual oxygen measuring device — Power cable — Hose set, 3 m, including filter and cannula — Calibration certificate — Transport case Measuring range: 5 ppm - 21% O2 Ambient temperature: 0–45° C Measurement accuracy: +/- 0.3 mV (EMK sensor) Warm-up time: 3–5 min Response time: approx. 2 sec. for changes Dimensions (L x W x H): 180 x 210 x 85 mm without handle Mains voltage: 100-240 V AC Warm-up power: approx. 40 VA Control power: approx. 20 VA Weight: 2.1 kg...
Germany, Wutöschingen
...FSH - The Unique High-temperature sensor for measuring medium temperatures up to 190°C, maximum ambient temperature 80°C, protective coating ceramic or Teflon; protection class IP68 Product Description FSH - High-Temperature Probe This version of the moisture measuring probe is a special feature. It can measure the moisture in the measuring medium at temperatures of up to 190°C (maximum...
Germany, Ettlingen
... calibration certificate. The RMD is characterized by a very high resolution, a high measuring range, a data interface and the illuminated graphic display. Dimensions:68 x 25 x 15 mm Weight:~ 70 g Measurement range:0 - 20 W/cm² Operation temperature:0 to 60 °C Storage temperature:-10 to 60 °C...
Switzerland, Reinach Bl
...The multiple award-winning intelligent thermometer with integrated HART® transmitter and Heartbeat Technology features the world's first RTD sensor capable of fully automated in-situ self-calibration. The device virtually eliminates the risk of undetected non-conformities, reduces production downtime, and enhances product safety and process efficiency in facilities within the beverage, food, and life sciences industries. It complies with FDA 21 CFR Part 11 requirements and GMP guidelines.
Switzerland, Wohlen
...• Programmable without any power supply connection • Zero and span calibration via software • Suitable for temperature measurement in hazardous areas • Sensor breakage and short-circuit monitoring...
Germany, Hückelhoven
...The sensing element of these accelerometers provides a sensitivity of (±10%) 100 mV/g (10.2 mV/(m/s²)) with a frequency range of (±3dB) 30 to 480000 cpm (0.5 to 8000 Hz). — Industrial ICP® vibration sensor — Continuous operating temperature up to 163 °C — With through hole — Measuring range 50 g — Sensitivity 100 mV/g — Frequency range 0.8 ... 8,000 Hz — Single-point calibration at 100 Hz — 2-pin connection socket on the side Please contact us directly for an individual offer.
Germany, Falkensee
... procedures. We conduct factory calibrations as well as accredited calibrations (according to DAkkS/DKD) in our own calibration laboratory. For more information about our data loggers, please visit our Valilog website.
... designs is available for the application. For in-process calibration, the integration of a special measuring insert with an additional test tube is possible (see data sheet T4-025-45, type GA3100, reference sensor see data sheet T4-025-46, type GA3110). Mechanical design: Measuring insert replaceable with connection head and protective fitting...
Germany, Kirchzarten
... the connection of optical or acoustic alarms when thresholds are exceeded or not met. These thresholds can be parameterized for both the internal differential pressure sensor and the external humidity, temperature, or pressure measuring transducers. The PUC 28 is ideal for wall installation in clean rooms due to its smooth and solvent-resistant plastic surface. The optional PROFIBUS DP interface...
Germany, Betzigau
... material deposits on the arm. This further increases the operational reliability of the capacitive limit switch. ATEX approvals are provided. Approvals: ATEX, IEC-Ex, FM, EHEDG, TR-CU, CCC-Ex, KCs Process temperature range: -40°C to +240°C Pressure range: -1 bar to +25 bar Sensitivity: DK value >= 1.5...
France, Lacq
... installation and commissioning Very long product lifespan Robust, economical, and maintenance-free system Possibility to supply the complete flow meter including the 25/25 flow meter, upstream and downstream straight lengths, and if necessary, the temperature sensor and multivariable differential pressure transmitter Residual pressure loss: 42% at 95% of ∆P(1 Accuracy: <1% to 2.5% depending on...
Slovenia, Šentjernej
...Constant voltage excitation Easy to use DIP package Wide compensated range (0 to 70°C) Zero and span calibration Ratiometric 90 mV full scale output Differential, gage and absolute configuration 10 mBar – 7 Bar Pressure Ranges:10 mbar ÷ 7 bar Accuracy:up to ± 1% FS Dimensions:27,4 x 27,9 mm Temperature range:-25°C ÷ 85°C Temperature compensation rate:0°C ÷ 70°C...
Germany, Bad Bramstedt
...SHT75DK Digital, High Precision Sensor for Humidity and Temperature The digital humidity sensor SHT75DK comes fully calibrated and is easy to install thanks to its pin-type package (for 1.27mm sockets). Individual calibration and digital output make it a fully exchangeable option and also spare you the painful and intricate recalibration after changing it. Its sensor head is connected to the pins...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play