... due to permanent deformation of the sensor element. Measuring ranges: 0 … 1 N / 0 … 2 N / 0 … 5 N / 0 … 10 N / 0 … 20 N Force direction: Tensile and compressive Standardization: Optional Output signal: 1 mV/V Protection class: IP20 Overload protection: Yes Operating temperature range: -20 ... +80 °C Special features: Small dimensions Special features: Easy installation Special features: Special designs available upon request Special features: Burster TEDS optionally available...
... response time of the thermocouple is desired Not protected against furnace atmospheres or electrical interference Type N, 2mm ⌀ mineral-insulated for uniformity tests (TUS) according to AMS 2750D Calibration according to AMS 2750 and CQI-9 Less susceptible to oxidation, may be reused multiple times Type K, fiberglass-insulated high-temperature probes for windshield production Used with mounting kit...
Germany, Donaueschingen
...The B+B measuring transducer module Pt1000 with voltage output 0-10V, is an accurate reliable digital measuring transducer in a miniaturised PCB design with modern ASIC technology - digitally calibrated for connecting Pt1000 sensors. Name:Measuring transducer module with customer-specific calibration Temperature measuring range:Selectable between -200...+650 °C Sensor:Platinum sensor Pt1000...
Germany, Hamburg
... resistance - IP68, IP69K - Suitable for Smart Calibration - intelligent calibration without the use of mass standards - Optional version with dual measuring bridge available - Ex versions available - Optional version with an extended operating temperature range up to 150°C - Accuracy class L (0.5%) and N (0.06%) - When combined with selected mounting kits, certified according to EN 1090...
... Analog output:± 0.25 % FS Drift vs Ambiant Temperature Analog output:± 0.25 % FS Sensitivity:Linear (See calibration table) mV/°C Sampling frequency:5 Hz Supply Voltage:5–16 V or 12–33 V Supply Current:3 mA Output Voltage:0–5 V or 0–10 V Output Impedance:47 Ω Digital output:ASCII @ 5hz, 9600 Bauds Calibrator:Fluke 714 Dimension “P” type:35 x 20 x 10 mm Material “P” type:Plastic Dimension “A” type:32.5 x 19 x 10 mm Material “A” type:Aluminium Weight:15 g Protection:IP53 Vibration test:20Gpp5’ Shock:500 G Operating Temp:-40 to +125 °C Storage Temp:-40 to +125 °C...
Germany, Mainz
... on highly stable, piezoresistive pressure measuring cells, which are mounted together with an ASIC on a ceramic substrate. The sensors are compatible with the SM5852 as their successor and feature a more modern ASIC for improved temperature compensation and calibration.
...EGE amplifiers process the signals of the EGE filling level sensors for extreme temperatures at a safe distance and are used to set up the sensor via intuitive operation using potentiometer and LED strip. Amplifiers for EGE high temperature limit switches feature an auto-calibration of the switching point at the press of a button. EGE amplifiers provide switching signals or analogue signals, dependent on the device.
Germany, Ortenburg
...The capaNCDT DT61x4 is an active, capacitive system for displacement, distance and position measurements. Consisting of a sensor with integrated preamplifier, a robust cable and a compact controller, the measuring system is immediately ready for use without any on-site calibration. The measuring system is available with a cable length up to 15 m and is ideal for automation purposes. The capaNCDT...
Germany, Seligenstadt
...— Residual oxygen measuring device — Power cable — Hose set, 3 m, including filter and cannula — Calibration certificate — Transport case Measuring range: 5 ppm - 21% O2 Ambient temperature: 0–45° C Measurement accuracy: +/- 0.3 mV (EMK sensor) Warm-up time: 3–5 min Response time: approx. 2 sec. for changes Dimensions (L x W x H): 180 x 210 x 85 mm without handle Mains voltage: 100-240 V AC Warm-up power: approx. 40 VA Control power: approx. 20 VA Weight: 2.1 kg...
Germany, Wutöschingen
...FSH - The Unique High-temperature sensor for measuring medium temperatures up to 190°C, maximum ambient temperature 80°C, protective coating ceramic or Teflon; protection class IP68 Product Description FSH - High-Temperature Probe This version of the moisture measuring probe is a special feature. It can measure the moisture in the measuring medium at temperatures of up to 190°C (maximum...
Germany, Ettlingen
... calibration certificate. The RMD is characterized by a very high resolution, a high measuring range, a data interface and the illuminated graphic display. Dimensions:68 x 25 x 15 mm Weight:~ 70 g Measurement range:0 - 20 W/cm² Operation temperature:0 to 60 °C Storage temperature:-10 to 60 °C...
Germany, Hückelhoven
...The sensing element of these accelerometers provides a sensitivity of (±10%) 100 mV/g (10.2 mV/(m/s²)) with a frequency range of (±3dB) 30 to 480000 cpm (0.5 to 8000 Hz). — Industrial ICP® vibration sensor — Continuous operating temperature up to 163 °C — With through hole — Measuring range 50 g — Sensitivity 100 mV/g — Frequency range 0.8 ... 8,000 Hz — Single-point calibration at 100 Hz — 2-pin connection socket on the side Please contact us directly for an individual offer.
Germany, Falkensee
... procedures. We conduct factory calibrations as well as accredited calibrations (according to DAkkS/DKD) in our own calibration laboratory. For more information about our data loggers, please visit our Valilog website.
... designs is available for the application. For in-process calibration, the integration of a special measuring insert with an additional test tube is possible (see data sheet T4-025-45, type GA3100, reference sensor see data sheet T4-025-46, type GA3110). Mechanical design: Measuring insert replaceable with connection head and protective fitting...
Germany, Kirchzarten
... the connection of optical or acoustic alarms when thresholds are exceeded or not met. These thresholds can be parameterized for both the internal differential pressure sensor and the external humidity, temperature, or pressure measuring transducers. The PUC 28 is ideal for wall installation in clean rooms due to its smooth and solvent-resistant plastic surface. The optional PROFIBUS DP interface...
Germany, Betzigau
... material deposits on the arm. This further increases the operational reliability of the capacitive limit switch. ATEX approvals are provided. Approvals: ATEX, IEC-Ex, FM, EHEDG, TR-CU, CCC-Ex, KCs Process temperature range: -40°C to +240°C Pressure range: -1 bar to +25 bar Sensitivity: DK value >= 1.5...
Germany, Bad Bramstedt
...SHT75DK Digital, High Precision Sensor for Humidity and Temperature The digital humidity sensor SHT75DK comes fully calibrated and is easy to install thanks to its pin-type package (for 1.27mm sockets). Individual calibration and digital output make it a fully exchangeable option and also spare you the painful and intricate recalibration after changing it. Its sensor head is connected to the pins...
Germany, Donaueschingen
... humidity - Fast response time - High chemical resistance - Wide humidity and temperature range - I²C protocol (address 0x28 or alternative address) - Direct replacement without calibration possible Article number: MAT-HYT221 Sensor: Ceramic substrate with capacitive polymer sensing element Operating voltage: 2.7 - 5.5 V Measurement range: +/- 1.8 % 0 - 100% rF Temperature range: +/- 0.2 °C - 40 - + 125 °C Connection: SIL contacts RM 1.27 mm Dimensions: LxWxH 15.3 x 10.2 x 5.3 mm Current consumption: < 1 µA (25 °C sleep mode)...
...Oxygen combination sensor with built-in Type S thermocouple and holding tube connection. The standard dimensions are connectors with 22 x 150mm or 27 x 150mm in stock. The sensor is not heated. Minimum operating temperature is 500°C Configuration: Connection head form A with M20x1,5 cable gland Pressure range: Ambient to max 2 bar pressure Fitting: Thread G3/4" DIN 228 Thermocouple: 1 x...
... analog output. The current output is read back by the F01 to ensure the output signal is emitted correctly. To be able to use the F01 in many applications, users can select different pressure connections. The electrical contact takes place via a 5-pole M12 connector. Through the calibration of the transmitter via temperature, a total accuracy of 1 % FS can be achieved within a range of 0...80 °C...
Germany, Bad Oeynhausen
...The DAIP offers the user extreme ease of use combined with the advantages of the heated sensor tip. Thanks to the auto-zero function, direct calibration can be performed on the device or from the control room. The mass pressure transmitter provides mA or V signals at the output. Thanks to the patented sensor tip, the sensor can also be removed in the case of already cooled molten mass. This...
Germany, Darmstadt
... calibration curves that support most standard low-temperature sensors. Additionally, eight custom calibration curves are available for custom or calibrated sensors. Each user curve can have up to 200 entries. The temperature range depends on the specific sensor type and ranges from 500 mK to 1200 Kelvin. The controller offers various interfaces such as Ethernet, as well as optional GPIB and USB. LabView drivers are available for all interfaces.
... FPM (Viton®) gasket ▪ Weight: 200 g / .44 lbs ▪ Suitable for gases and liquids (in the case of aggressive media, only after consultation) ▪ Accuracy (±0,25% FS* typ.) ▪ Automatic sensor recognition ▪ Pressure connection G1/2 (without adaptor) ▪ Calibration certificate on request Ambient Conditions ▪ Media temperature: -25 °C ... +105 °C /-13 °F ... +221 °F ▪ Ambient temperature: -25 °C ... +85 °C / -13 °F ... +185 °F ▪ Storage temperature: -25 °C ... +85 °C / -13 °F ... +185 °F ▪ Compensated range: 0 °C ... +85 °C / +32 °F ... +285 °F ▪ Load cycles (10 6): 100 Electrical Data ▪ Response...
Germany, Münster
...2-channel temperature measuring device with external sensor connections including wall mount, lock, batteries, and calibration protocol. Sensors available in different designs. Large memory for 1 million measurement values - large, easy-to-read display.
Germany, Hohen Neuendorf Ot Bergfelde
Germany, Ratingen
... Measuring Unit: Pa Smallest Measuring Span: 0…200 Pa (2 mbar) Measuring Range Selection: Factory preset Storage Temperature: -25…+60°C PERFORMANCE: Overload Safety: 0.2 bar Static Pressure: Max. 0.2 bar Zero Point Calibration: Adjustable via REED contact, no cyclical zero point calibration required Reaction Time: Immediate...
... when moving between a high and low dew point process • Easy-to-use, simple operation, operator training in minutes • Rugged capacitive sensor • Long life rechargeable battery • NIST traceable calibrationCalibration certificate supplied with factory calibration...
... technology (automatic adjustment of the best x-ray energy) Compensation of forming belt inuences Two high speed traversing measuring heads for fast detection of weight variations in production direction No active cooling unit required (long life time of x-ray tubes) Automatic inline calibration during panel production Automatic compensation of sensor contaminations Automatic compensation of sensor temperature drifts Advantages The EcoScan NEO - FBD is able to detect smallest foreign bodies in a ber mat to prevent damages to the press belts.
Germany, Neufahrn
... applications. Specification: Measuring Principle: Thermal Mass, CMOS Sensor Sizes: ¼" and ½" Female G Flow ranges: 2 nml/min to 300 nl/min Accuracy: +/- 1% FS Calibration Gases: Air, O2, N2, He, Ar, CO2, H2, CH4, C3H8, SF6, and more upon request.
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play