... Smart technology, Revision 4.0 of the Bluetooth® standard, features sophisticated energy management. Combined with the energy-saving electronics of the HALO™ electrodes, this allows for a battery life of up to 500 hours of measurement time. A single CR2032 lithium cell is required for this. The battery status is transmitted, making it visible at any time in the Hanna Lab app or on the edge blu. Many different models are available, depending on the application.
Germany, Kahla
...Electrodes are subjected to high chemical stresses and must exhibit excellent electrical conductivity as part of a galvanic system. For these applications, platinum and its alloys are also exceptionally suitable. If your application requires a modification of dimensions or alloy, we are happy to assist you in developing the right product as a custom solution. Standard materials: Pt/Ir 90/10...
Germany, Heddesheim
We are a small, dynamic company with a groundbreaking new system in the field of measurement technology and data management, the iNet Sensor® concept.
Germany, Friedberg
...Task of the Neutralization System The Mini-Fix system is designed for decentralized use under the laboratory table and is characterized by its compact size, user-friendly operation, robust construction, and optimal price-performance ratio. The Mini-Fix neutralization system can also be used for cyanide and chromium detoxification through the use of special electrodes and chemicals. Process...
Germany, Neustadt/wied
... is suitable for use in scientific laboratories, educational institutions, medicine, and industry. Available in stainless steel and regular steel versions. SNOL 75/350 - Suitable for electrodes up to 40 kg and a length of 45 cm - Temperature adjustable from +50 to +350 °C - Outer casing – gray, powder-coated steel sheet - Robust steel constructions ensure the longevity of the product - Natural air convection - Thermal insulation wool ensures energy efficiency of the oven, keeps the electrodes hot, and protects against moisture...
Germany, Waldkappel
HILGENBERG GMBH – THE COMPANY Hilgenberg GmbH was founded around 1913 in Stützerbach in the Thuringian Forest – a place known for its rich tradition in glass manufacturing. At that time, it was probably hard to imagine that nearly 100 years later we would be developing and producing high-precision glass products with the finest manufacturing tolerances in the micrometer range. Today, three gener...
We are your powerful partner in glass apparatus construction and laboratory supplies. We manufacture for: Chemistry - Physics - Environmental laboratories - Biolabs - Medicine - Universities - Schools...
Germany, Sulz Am Neckar
... small components, for example in the electronics sector. Diamond wire with a core diameter of 180µm is especially suitable for sample cuts in laboratory settings. Additionally, it is suitable for sawing graphite electrodes.
Germany, Gießen
... environment, or in a hazardous area – we have the right analog or digital pH electrode for the most accurate and reliable measurements. Our selection of inline pH electrodes and measuring devices includes - Hygienic design pH electrode - ATEX and FM approved measuring probe - pH electrode for pure and ultrapure water - Digital sensors with preventive diagnostic functions - Glass-free pH electrode...
...In this cell type, a granulate of electrolyte graphite is used as the cathode. Due to the very large surface area, the current yields remain economically viable even when operating at the threshold limits. The applications of electrolysis systems in aqueous solutions are very diverse. By appropriately selecting the electrodes, a variety of oxidation and reduction reactions can be carried out. The...
...potting, ... Dimensions (Table Top):269 - 423 mm x 300 - 443 mm x 176 - 290 mm (WxHxD) Vacuum Chamber material:Borosilicate glass (HP), RIE - bell aluminium, soda-lime glass Vacuum Chamber dimensions:Ø 105 mm Tiefe 200/300 mm // Ø 190 mm Tiefe 60 mm // 135x120x65 mm Vacuum Chamber volume:approx. 1 - 4 litres Vacuum Chamber closure:Lid, hinged door Gas supply:Needle valves, Mass Flow Controllers (MFCs) Generator:100 kHz / 0 - 30 W Electrodes:a pair of electrodes outside the vacuum chamber Controles:2 - Step switch Power supply:230 V / 50 - 60 Hz Vacuum pump:Capacity: approx. 3 m3/h...
... Further advantages of the Preciano iQ - Cost-effectiveness through innovative bath heating and efficient gold bath consumption - Patented reactors with flow breakers ensure high result reliability - Intuitive operation and self-calculation of nearly all parameters Scope of delivery - Galvanizing head, grid electrode - Power cable - Glass reactor “S” (max. 220ml, max. 6 objects) - Glass reactor “M” (max. 400ml, max. 6 objects) - Preciano iQ – Squirl set (consisting of 2 stirrers) - 2 × recycling electrodes - Determination table “Preciano iQ Chart” - Item No.: 6600 9741...
Germany, Judenbach-Heinersdorf
... manufacture composite components for special requirements. Ignition Components: As part of Rauschert's success story, the production of ceramic insulators for spark plugs and ignition electrodes began in the mid-1980s. Shortly thereafter, we developed the first complete ignition electrodes for the oil and gas burner market. Since 2006, we have also been producing ceramic heating elements for high...
Germany, Leopoldshöhe
... our customers' wishes. Today, capilla® guarantees the highest quality and safety with a modern analysis laboratory, under the leadership of a PhD. In this way, capilla® sets global standards in modern welding technology. Whether it’s manual electrode welding, MAG welding, MIG welding, TIG welding, UP welding, or flux-cored welding: in our extensive product range, you will find the optimally suitable welding filler for all welding processes.
Germany, Kassel
... applications, HydroFlex - the practical hydrogen reference electrode, pHydrunio - the pH single probe measurement chain for challenging measurement media, SiRef - silver-silver chloride reference electrodes made of PTFE, SOC state of charge sensor - for measuring sulfuric acid density in lead-acid batteries, and FlexCell - the measurement cell for electrochemical half-cell measurements in the laboratory. Gaskatel has since been a competent contact for fuel cells & electrolyzers, development projects, and electrochemical measurements such as corrosion.
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store