Suitable for emergency stop and continual use. Energy reduction: 25% to 45%. Dynamic force absorption: 218 N to 3730 N Impact velocity: max. 5 m/s. The profile dampers are maintenance-free and are supplied ready to install with a special fastening screw. Environment: Resistant to microbes, sea water, chemicals and with very good UV and ozone resistance. No water absorption or maceration. Application: Linear slides and linear guides, pneumatic cylinders, furniture industry, machines and plants.

Request for a quote

France

Verified by Europages

Suitable for emergency stop and continuous use Energy reduction: 58% to 73% Dynamic force absorption: 870 N to 35190 N Impact velocity: max. 5 m/s. The profile dampers are maintenance-free and are supplied ready to install with a special fastening screw. Environment: Resistant to microbes, sea water, chemicals and with very good UV and ozone resistance. No water absorption or maceration. Fastening screws: Special cap screws with hex sockets, material 44SMn28 (free-cutting steel SAE 1144) electro zinc-plated: M6x9, M6x10, M8x14, M12x18, M16x26 ISO 4762 cap screws with hex sockets - 8.8 steel, black: M3x6, M4x8**, M5x10** ** With DIN 125 washer, electro zinc-plated steel. Application: Linear slides and linear guides, pneumatic cylinders, handling equipment, machines and plants

Request for a quote

Portugal

Verified by Europages

Handle with emergency stop Easy blade tilt adjustment Easy working height adjustment hour counter gasoline engine

Request for a quote

Portugal

Verified by Europages

The concrete trowel helicopter is equipped with a Robin Subaru EX27 engine. Features: Handle with emergency stop Easy blade tilt adjustment Easy working height adjustment hour counter Robin Subaru EX27 gasoline engine

Request for a quote

Portugal

Verified by Europages

The LIS Helicopters for smoothing concrete have an easy adjustment of blade inclination, handle with emergency stop and hour counter. Technical Features: 600mm Overall diameter. 230x120mm Measure blades. 60Kg Weight.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Safety management in a compact 22.5 mm format Mono or two-channel with wiring. "Low consumption" Inputs Removable terminals Performance level with AWAX controller: PL = d Safety category: 3 (two-channel) Safety Integrity Level: SIL 2 Time before dangerous failure: MTTFd = 240 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 2x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant + 1x NO static 400 mA Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Safety management in 2 zones in a compact 45 mm format Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics zone 1: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Safety contacts/diagnostics zone 2: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Indicators: 2 display LEDs per zone for diagnostics and 1 LED for power Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management on 9 outputs in a compact 45mm housing Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 75 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant in serial (XXL version) or parallel (XXLP version) Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management with 85~265 VAC power Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C