Results for

Measurement transformers - Import export

Germany

Verified by Europages

Initiator cables, also referred to as sensor/actuator cables, connect control units and different sensors, or, in the case of reversal of the measurement principle, actuators. Frequently used abbreviations include ini or ini cable (plural: inis). Sensor or measurement transducers transform physical quantities such as rotation, speed, distance or length into analogue electric impulses. In the case of an actuator, the measured electric current (symbol: I, unit: ampere; A) or voltage (symbol: U, unit: volt; V) is transformed into temperature, pressure or torque. The connection cable consists of at least three cores with a small cross-section of between 0.14mm² and 0.34mm². In the simplest case, two cores are required for supplying the voltage, while the last core transmits an I/O signal. For sensitive applications, there are shielded versions in addition to the traditional ini cables to avoid EMC disruptions (electromagnetic compatibility).

Request for a quote

Germany

Verified by Europages

Fast and accurate measurements of the smallest resistance values are possible with the milliohmmeter RESISTOMAT® model 2316. Due to the rugged aluminium injection moulding desktop housing with membrane keypad it is suitable for use in laboratory and industrial environment likewise. Wires and coils can be measured with temperature compensation. The temperature of the sample is measured with a Pt100 or pyrometer and the resistance is then corrected to the equivalent at e.g. 20 °C (adjustable) in the instrument. The application range is very wide such as the measurement of: — transformer motor coil windings — coils of all kind — cables and wires on the drum or as meter samples — switch and relay contacts — heating elements — fuses — connections and transitions at power rails and many more Specific characteristics: — Autorange — Temperature compensation for all materials — Thermal e.m.f. compensation — Input voltage protection up to effectively 400 V rms

Request for a quote

Belgium

Verified by Europages

Assessment & Maintenance Plan Transformers are low maintenance, but not free of maintenance. To determine the maintenance need of your transformer(s), Maintenance Partners offers an assessment that consists of visual inspections, oil sampling, thermography and electrical measurements. The assessment is the foundation for a maintenance plan in which the condition and priority of each transformer are decisive for the maintenance frequency and needs. Transformatoren Maintenance Partners - Preventief Onderhoud - StaalnamePreventive Maintenance For a safe and reliable operation of transformers, preventive maintenance is a must. This detects problems at an early stage and can prevent further deterioration. Preventive maintenance includes the following tests: Oil sampling + analysis (Oil quality, PCB, furan detection, moist level, …) Electrical measurements (Insulation resistance, Winding resistance, Transformer Turn Ratios, SFRA-Sweep Frequency Response Analysis, IDAX- Tgδ, …)

Request for a quote

Switzerland

Verified by Europages

Magtrol offers three types of torque transducers for dynamic torque and speed measurement. All three transducer models employ our unique non-contact differential transformer torque measuring technology. This measuring technology offers many benefits most notably that no electronic components rotate during operation. Each model has an integrated conditioning electronic module providing a 0 to ±10 VDC torque output and an open collector speed output. Magtrol’s Torque Transducers are very reliable, providing high overload protection, excellent long-term stability and high noise immunity.

Request for a quote

United Kingdom

The Premium Sound Level Meter in the Pulsar Nova range. Class 1 (Model 45) or Class 2 (Model 46) available. Featuring a high-resolution full colour OLED display: ideal for any application, anywhere. Data Logging with Audio Note recording supplied as standard. Description: Occupational noise measurement at its best The Pulsar Model 45 sound level meter (Class 1) and Pulsar Model 46 sound level meter (Class 2) are very accurate, reliable, ‘handheld’ precision instruments that are especially suited to Noise at Work and Occupational & Industrial Hygiene applications. They can be used for boundary and entertainment noise measurement, machinery and vehicle noise testing. Simplicity of use combined with the outstanding Pulsar ‘AnalyzerPlus’ reporting software (supplied as standard) allows you to effectively measure noise, store your measurements in the large internal memory and then effortlessly transform your measurements into final report formats ... ** Ask for a quote **

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Measuring transducer for temperature (Pt1000). Simple application; for harsh environments. Compact design for mounting side by side. Fine adjustment of the measuring range via sealed integrated trimming potentiometer. Operating status indication via integrated LED. Approvals: BV, DNV-GL, LR

Request for a quote

Germany

A micro-electromechanical spring-mass-system is continuously measuring the acceleration and transforms the measured data into an analog 4-20mA output signal. The sensor complies with the standards of DIN EN 50155 for railway vehicles. It is espacially intended to be used in the on-board network of rail vehicles. Its extrem rugged housing enables applications in harsh conditions in the outskirt area of the vehicle, directly at the bogie. The sensor impresses by its high ruggedness against impact, dust as well as moisture and guarantees high reliability. The device detects accelerations in a measuring range of ± 4g and operates with 110 Volt supply voltage.

Request for a quote

Germany

A micro-electromechanical spring-mass-system is continuously measuring the acceleration and transforms the measured data into an analog 4-20mA output signal. The sensor complies with the standards of DIN EN 50155 for railway vehicles. It is espacially intended to be used in the on-board network of rail vehicles. Its extrem rugged housing enables applications in harsh conditions in the outskirt area of the vehicle, directly at the bogie. The sensor impresses by its high ruggedness against impact, dust as well as moisture and guarantees high reliability. The device detects accelerations in a measuring range of ± 4g and operates with 24 Volt supply voltage.

Request for a quote

Ukraine

The TOR-2 transformer oil express-tester is designed to determine the moisture and hydrogen content in mineral insulating oils and ether based insulating oils. Moisture and hydrogen content is measured in parts per million (ppm). Knowing the content of hydrogen and moisture in the oil, as well as the rate of parameter change, it is possible to detect problems developing in the transformer in advance and to take timely measures to prevent damage to the transformer. Moisture measurement The device measures the activity of the water using a capacitance sensor, which ensures stability over time and contamination resistance. The oil temperature is also measured. The moisture content is calculated from these measurements. Hydrogen measurement A highly selective solid state sensor immersed directly in oil is used to measure hydrogen content. The sensor ensures accuracy and reliability of direct measurements.

Request for a quote

Ukraine

The unit is designed to measure the dielectric strength of transformer oil and other dielectric fluids according to IEC 60156, ASTM D877, ASTM D1816. It is a fully automatic device - allows testing according to the procedures defined in these standards, as well as according to the user procedures specified in the appropriate section of the setup menu. The core of the unit is the high voltage transformer and electronic modules. The unit operates by gradually increasing the voltage on the secondary winding of the high voltage transformer from zero to the maximum voltage, or to the voltage at which an electric breakthrough occurs in the dielectric fluid in the measuring cell installed on the high voltage contacts of the transformer. During operation, AC (50-60Hz) voltage is supplied from the secondary winding terminals through the cell electrodes into the dielectric fluid in the measuring cell.