• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • temperature transmitters

Results for

Temperature transmitters - Import export

Manufacturer/producer

Romania

The LSP-TSTS is a slim design easy to use temperature transmitter for Pt100/Pt1000 3 wire or 2 wire temperature sensor. This device provides a linearised 4-20mA signal output, proportional to the temperature characteristic of the Pt100 or Pt1000 sensor. Temperature range can be changed on request before order (Default -15 to 150ºC). Features • RTD type Pt100 or Pt1000 Input • 4 to 20 mA linearised output on current loop or 0-10V • TS-35 DIN rail mounting • +/-0.1% accuracy • Ip40 case • Screw terminals • Easy to use • Supply from current loop

Request for a quote

United States

The Series VTP Multi Range Air Velocity Transmitter can simultaneously display and output Air Velocity, Temperature and Pressure (optional). This is the first product to combine all 3 variables in one transmitter making the VTP an exceptional option for multi-variable measuring. The VTP utilizes an industrial 316 Stainless Steel armored RTD sensor as the thermal air velocity measuring component. Using a fully protected 316 SS sensor drastically extends the life of the air velocity sensor and also makes it insensitive to water, dust or corrosion. The VTP comes standard with a LCD and can simultaneously display air velocity, temperature, and pressure. The VTP is easily configured or adjusted in the field with the digital display and keypad. The Air Velocity Range and Pressure Range are both field adjustable as well as units of measure. Other adjustable parameters include signal dampening and low velocity cut off point.

Request for a quote

China

NCS-TT105 Temperature Transmitter adopts fieldbus technology, is a new generation of fieldbus smart temperature transmitter, and is an indispensable field device in process control. NCS-TT105 smart temperature transmitter supports HART, FF, PA protocol and can be widely used in petroleum, chemical, power plant, metallurgy and other industries. NCS-TT105 Smart Temperature Transmitter: 1. Support the latest versions of FF H1, PROFIBUS PA and HART protocols 2. Support 6 types of thermal resistance and 8 types of thermocouple 3. Thermal resistance supports 2-wire, 3-wire and 4-wire 4. The cold end compensation accuracy of thermocouple is ± 1.0℃ 5. High precision (better than grade 0.1), low temperature drift (better than ± 50ppm/℃)

Request for a quote

Germany

The CarbonSender™ transmitter provides a cost-effective solution for carbon potential and temperature transmission (4-20 mA) to your PLC or SCADA system via Modbus RTU. This DIN rail module provides full probe maintenance / probe burn off functions and reports probe status after each test. Up to four CarbonSenders can be integrated with reference air and burn off functions for up to four probes in a single enclosure.

Request for a quote

Belgium

This self-calibrating CO2 sensor measures CO2 as well as temperature, relative humidity and ambient light conditions. It needs a 24 VAC supply voltage. This sensor can also directly control an EC-fan, AC fan speed controller or frequency inverter. It has 1 single analogue / modulating output depending on the highest measured value for temperature, humidity or carbon dioxide. If you only want to use it for measuring CO2, you can deactivate the temperature or humidity measurement. The FCMFX-series are available for different types of supply voltages such as 24 VDC, 24 VAC/VDC or 230 VAC. All version have 3 LEDS on the frontpanel showing whether the measured value is within or out of range. Additionally they are available in a version with audible alert. All parameters are accessible via Modbus RTU. This sensor doesn't need to be configured. Once installed it's ready for use.

Request for a quote

Germany

Verified by Europages

Freely scalable Adjustable Pt 1000 resistance sensor Assembling to application needs

Request for a quote

Germany

Verified by Europages

With Pt100 or Pt1000 sensor NiCr-Ni sensor also available Scalable versions available With practical angle plug

Request for a quote

Germany

Verified by Europages

Several probe lengths available Max. measuring range -200 to +500 C With Pt1000 sensor, Compact design, high precision

Request for a quote

Switzerland

Verified by Europages

The ultra-fast M8coolHB pressure transmitter can process pressure changes with a bandwidth of 50 kHz. This is achieved by means of the continuous analog signal that is adjusted by a digital circuit in real time and is amplified to a standardised 0...10V signal. The miniature sensor head with a fine M8 thread can withstand temperatures of up to 1000 °C with suitable cooling, is overload-proof up to a magnitude of five times the measuring range, and is also resistant to vibrations.

Request for a quote

Germany

Verified by Europages

Lance design and compact design Switching and range up to 200 C 4..20 mA/0..10V/ 2 x push pull Stainless steel material

Request for a quote

Germany

Verified by Europages

Lance design and compact design Switching and range up to 200 C 4..20 mA/0..10V/ 1 x push pull Stainless steel material

Request for a quote

Switzerland

Verified by Europages

The ultra-fast M5HB pressure transmitter can process pressure changes with a bandwidth of 50 kHz. This is achieved by means of the continuous analog signal that is adjusted by a digital circuit in real time and is amplified to a standardised 0...10V signal. The miniature sensor head with a fine M5 thread can withstand temperatures of up to 180 °C, is overload-proof up to a magnitude of five times the measuring range, and is also resistant to vibrations.

Request for a quote

Switzerland

Verified by Europages

The high-temperature pressure transmitters of the 35XHTC series can be used at media temperatures of up to 300 °C. The remote electronics are designed for temperatures of up to 120 °C. They use digital compensation with a mathematical model to achieve an accuracy of 0,5 %FS – in the temperature range from 10 to 40 °C, this value even corresponds to the total error band. In addition to the digital RS485 interface, the X-line transmitters have a rangeable, analog current or voltage output. The standard model of the 35XHTC series has a G1/2 thread as pressure connection.

Request for a quote

Germany

Verified by Europages

Temperature transmitter transform the voltage signal of thermocouples or the resistance change of platinum sensors (Pt100) to a 4…20 mA (current loop) or 0…10 V signal.

Request for a quote

Germany

Verified by Europages

Temperature transmitter transform the voltage signal of thermocouples or the resistance change of platinum sensors (Pt100,Pt1000) to a 4…20 mA (current loop) or 0…10 V signal.

Request for a quote

Germany

Verified by Europages

The RESISTOMAT® model 2311 has been designed and optimized for high-speed applications in automation systems. Up to 100 measurements per second can be achieved. It works on the basis of the welltried four-wire measurement method in which test-lead resistances and contact resistances are eliminated. The instrument leads are monitored for damage by a built-in open circuit detector. A 2-way and 4-way comparator with switching outputs is available for classifications and selections. Of course, temperature compensation is available for any test object material. Specific temperature coefficients can be entered. Temperature recording takes place using a PT100 sensor or a temperature transmitter (pyrometer) with an analog output. A special circuit for protecting the measurement input when measuring inductive test objects has been developed to prevent damage to the meter from voltage peaks produced when the test object is disconnected.

Request for a quote

France

Verified by Europages

Different types of pressure transmitters exist: differential pressure transmitter for measuring a pressure difference ΔP but also a relative or absolute pressure transmitter. For more specific applications, it will be necessary to use: a differential pressure transmitter to correct variations of pressure and temperature of a gas two transmitters for the same differential pressure flow element to increase the measuring range For more details on these cases, please see the Frequently Asked Questions tab on this page.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Verified by Europages

Analogue 2-wire temperature Transmitter The OPTITEMP TT 10 is an analogue, multirange 2-wire temperature transmitter which works together with RTDs of the type Pt100. The main field of application is an industrial environment, therefore the device has a high reliability and an excellent industrial performance. The OPTITEMP TT 10 series consists of 2 different versions in terms of the mounting. The TT 10 R is the rail-mount version for DIN rails whereas the TT 10 C is primarily intended to be mounted in a "B connection head" or larger according to DIN EN 50446. As an alternative you can also mount the in-head version on a DIN rail according to EN 60715 with the help of an optionally available rail mounting kit.

Request for a quote

Germany

Verified by Europages

Analogue 3-wire temperature Transmitter The OPTITEMP TT 11 is an analogue, multirange 3-wire temperature transmitter which works together with single resistance thermometers of the type Pt100 and Pt1000. A special feature of the device is its 0...10 VDC output that predestines it for the HVAC systems in building services applications. The transmitter has a high reliability and a good industrial performance. The OPTITEMP TT 11 series consists of 2 different versions in terms of the mounting. The TT 11 R is the rail-mount version for DIN rails whereas the TT 11 C is primarily intended to be mounted in a "B connection head" or larger according to DIN EN 50446. As an alternative you can also mount the in-head version on a DIN rail according to EN 60715 with the help of an optionally available rail mounting kit.

Request for a quote

Germany

Verified by Europages

Sensor with extension tube for screw-in The OPTITEMP TRA/TCA-S12 is a temperature assembly for screw-in. It is predominantly used in the lower temperature range (up to +150°C / +302°F). When it features a neck tube, spatially separating the process connection from the  connection head, the connection head cannot heat up as much. This is particularly important when there is a temperature transmitter in the connection head. Form acc. DIN 43772: Form 2G Design: DIN-style, welded, multipart thermowells Process connection: threads: G 1/2, G 3/4, G 1, 1/2" NPT and 3/4" NPT Neck tube connection: with fixed neck tube Tip design: straight tip Diameter: Ø 9, 10, 11 and 12 mm

Request for a quote

Romania

This device is an advanced transmitter for measuring conductivity and temperature in water treatment applications. It uses WiFi communication for configuration and has configurable analog outputs for both conductivity and temperature measurements. Additionally, it can be connected with sensors that have any type Features • WiFi connection for configuration • MODBUS • Conductivity, resistivity and temperature measurement • Configurable signal output for the conductivity (0 -20mA; 4-20mA; 0-24mA; 0-10V) • Configurable signal output for the temperature (0 -20mA; 4-20mA; 0-24mA; 0-10V) • Switching digital output Relay (Switching point is configurable through setup program) • Cyclical self calibration • Linear temperature compensation • Electrically isolated input, output and supply • DIN rail mounting • Compensation of the cable capacity • Calibration of the cell constant https://www.youtube.com/watch?v=uD7sGGopCY0

Request for a quote

China

Parameters Basic Parameters Bus Power Supply: 9~32VDC Current consumption (static):≤14mA(FF/PA) 11V~35 VDC(HART) Input Signal: Pt100, Pt1000, Cu50, Cu100 Ω, 0, 0 to 500 ~ 4000 Ω Resistance, B, E, J, N, K, R, S, T eight degrees of Thermocouple, -100mV ~ 100mV Voltage Signal The Channel Number: Single Channel Fieldbus Protocol: FF/PA/HART Insulation: Between the Terminal and the Housing:500Vrms(707VDC) Operating Temperature: -40℃~85℃ Humidity Range: 0%~95%RH Starting Time: ≤5secs. Turnover Time: 0.5secs. Electromagnetic Compatibility: In Line with the GB/T 18268-2010 Explosion-Proof Sign: Ex ia IIC T4 Ga (HART)

Request for a quote

China

It's very popular that our pressure and temperature measurement transmitters in oil and gas market , and HART modem is essential basic equipment. For some customers who want to connect two different industrial networks, we provide a cost-saving solution that gateways equipment. It basically realizes full communication, for Modbus, HART, Profibus, FF and DP. G0310 Modbus to HART Gateway, designed by Microcyber Corporation is a gateway device for Modbus-RTU protocol and HART protocol. As Modbus master, G0310 Modbus to HART Gateway communicates with devices that have Modbus-RTU communication function via RS485 interface. It can convert device data to HART device variables output, and it also supports 4~20mAcurrent output. Connect different control systems (Siemens, Emerson, Schneider Electronics, ABB, Yokogawa, Rockwell, etc.)

Request for a quote

Switzerland

• Fast measurement of DC voltage, DC current, temperature (RTD, TC) and resistance • System capability: Parameterising and readout of all input variables and internally calculated values via MODBUS • Setting time up to 10 ms • Sensor connection without any external jumpers • 2 inputs (e.g. for sensor redundancy or difference formation) • 2 outputs (I) • 2 inputs can be linked with each other and allocated to the 2 outputs which enables calculations and sensor monitoring (e.g. prognostic maintenance of sensors). • Freely programmable relay, e.g. for liwith or alarm signalling • AC/DC wide-range power supply unit • Pluggable high-quality screw or spring cage terminals

Request for a quote

Switzerland

• Measurement of DC voltage, DC current, temperature (RTD, TC) and resistance • Programmable remote I/O functionality. Readout of all input variables and internally calculated values via MODBUS. Simultaneously, the outputs and the relay may be controlled via MODBUS. • Free selection as to whether the output variables are dependent on the input variables or whether the outputs are controlled independently of the inputs via MODBUS. • Sensor connection without any external jumpers • 2 inputs (e.g. for sensor redundancy or difference formation) • 2 outputs (U and / or I) • 2 inputs can be linked with each other and allocated to the 2 outputs which enables calculations and sensor monitoring (e.g. prognostic maintenance of sensors) • System capability: Communication via Modbus interface • Freely programmable relay, e.g. for liwith or alarm signalling • AC/DC wide-range power supply unit • Pluggable high-quality screw or spring cage terminal

Request for a quote

Switzerland

• Programmable without any power supply connection • Zero and span calibration via software • Suitable for temperature measurement in hazardous areas • Sensor breakage and short-circuit monitoring

Request for a quote

Switzerland

Unsurpassed reliability, accuracy and long-term stability in critical processes. The remote configurable transmitter transfers and monitors converted signals from RTD sensors and thermocouples as well as from resistance and voltage signals using selectively HART®, FOUNDATION Fieldbus™-, PROFIBUS® PA-communication. It visualizes the signals on its own backlit display. A field housing allows a direct connection in harsh process areas as well as in hygienic applications as option.

Request for a quote

Switzerland

Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers digital converted signals from RTD and TC sensors, it also transfers resistance and voltage signals using FOUNDATION Fieldbus™ communication. High measurement point availability by means of sensor monitoring functions and device hardware fault recognition. Optimization of the measurement accuracy by sensor-transmitter matching.

Request for a quote

Switzerland

Unsurpassed reliability, accuracy and long-term stability in critical processes across all industries. The configurable transmitter transfers converted signals from RTD and thermocouple (TC) temperature probes, as well as resistance and voltage signals. The standardized 4 to 20 mA output signal is used for process measurement. Swift and easy commissioning, operation and maintenance via PC software or with integrated Bluetooth, technology and Endress+Hauser SmartBlue App.

Request for a quote

Request for quotes

Create one request and get multiple quotes form verified suppliers.

  • Only relevant suppliers
  • Data privacy compliant
  • 100% free