• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • safety relays

Results for

Safety relays - Import export

Manufacturer/producer

Germany

Verified by Europages

The programmable safety controller of the SCR P series is a smart alternative to the classic safety relays. Due to its multitude of applications it can replace various safety relay modules. This saves not only costs but also time, wiring effort and space. Up to 5 possible safety circuits with a max. of PL e, thereof 2 circuits with innovative DCD diagnostics allow logical connections to distinctively shutdown certain parts of a machine. Extensive diagnostic information can be retrieved via the Ethernet interface.

Request for a quote

Germany

Verified by Europages

In the field of safety sensors, we offer safety light screens in various lengths and types with up to 14 mm resolution and muting function. We offer laser scanners with large protective fields for special tasks. Two-hand buttons and controls round off the range. For direct connection to the machine, we also offer versatile controls in addition to simple safety relays.

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3, DIN EN 45545 (fire protection on railway vehicles) • With forcibly guided contacts • Safe separation betwenn coil/contact and contact/contact for applications at pollution degree 2 with rated insulation voltage 250 V • Clearance and creepage distances contact - coil ≥ 5.5 mm contact - contact ≥ 5.5 mm • Low nominal and holding power • High mechanical service life • Extremly smallest height only 10.3 mm and minimum area • RoHS compliance • Placing SMD components between PCB and relay is possible

Request for a quote

Germany

Verified by Europages

• Acc. to DIN EN 61810-1, DIN EN 61810-3, DIN EN 50578 (UIC 736) • With forcibly guided contacts • High switching reliability due to crown contacts • Clearance and creepage distances: contact - coil ≥ 8 mm contact - contact ≥ 5.5 mm Double and reinforced insulation with pollution degree 2 Overvoltage category: III • High voltage resistance ≥ 4 kV • High mechanical service life • High temperature range: - 40 ... + 75°C • High continiuous thermal current Ith = 10 A

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • High switching reliability due to crown contacts • Clearance and creepage distances: contact - coil ≥ 8 mm contact - contact ≥ 5.5 mm Double and reinforced insulation with pollution degree 2 Overvoltage category: III • High voltage resistance ≥ 4 kV • High mechanical service life • High temperature range at OA 5601 and OA 5602: -40 ... +85°C at OA 5603: -40 ... +75°C • High continiuous thermal current Ith = 10 A • High voltage range 0.7 ... 1.6 UN • As option wash proof RT III

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • High switching reliability due to crown contacts • Clearance and creepage distances: contact - coil ≥ 8 mm contact - contact ≥ 5.5 mm Double and reinforced insulation with pollution degree 2 Overvoltage category: III • High voltage resistance ≥ 4 kV • High mechanical service life • High temperature range at OA 5601 and OA 5602: -40 ... +85°C at OA 5603: -40 ... +75°C • High continiuous thermal current Ith = 10 A • High voltage range 0.7 ... 1.6 UN • As option wash proof RT III

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • Energy efficient; Low energy consumption, because of impulse control, no holding consumption • Bistable Mechanical latching of contact position • Safe separation between all current circuits • Both coils non-polarised, neutral • Defined position when both coils are operated simultaneously • Impulse operation, duty cycle possible (under fault condition) • Wide temperature range • As option with manual operation (mechanical indication) • Washproof (only without manual operation) • Height 15.8 mm

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • Clearance and creepage distances: contact - contact ≥ 5,5 mm • Low rated power consumption and holding power • High mechancial service life • High temperature range • High thermal continuous current • Height: 15.8 mm

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • High switching safety because of gold plated double contacts • Clearance and creepage distances: contact - contact ≥ 5,5 mm • Low rated power consumption and holding power • High mechancial service life • High temperature range • High thermal continuous current • Voltage range 0.75 ... 1.2 UN • 15.5 mm height

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • High switching safety because of gold plated double contacts • Clearance and creepage distances: contact - contact ≥ 5,5 mm • Low rated power consumption and holding power • High mechancial service life • High temperature range • High thermal continuous current • Voltage range 0.75 ... 1.2 UN • 15.5 mm height

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • Clearance and creepage distances: contact - contact ≥ 5,5 mm • Low rated power consumption and holding power • High mechancial service life • High temperature range • High thermal continuous current • 15,5 mm height • Version with double contacts possible, AgNi 0.15 + 5 μm Au-contacts

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • High switching reliability due to crown contacts • Very low rated power consumption OA 5611: 0.36 W with 4 contacts OA 5612: 0.5 W with 6 contacts • High mechanical service life • Compact size

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3, DIN EN 50578 (UIC 736) • With forcibly guided contacts • High switching reliability due to crown contacts • Low rated power consumption • High mechanical service life • Compact size

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • High switching reliability due to crown contacts • Very low rated power consumption OA 5611: 0.36 W with 4 contacts OA 5612: 0.5 W with 6 contacts • High mechanical service life • Compact size

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • High switching reliability due to crown contacts • Low rated power consumption • High mechanical service life • Compact size • Optionally wash proof

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • Clearance and creepage distances: contact - coil ≥ 8 mm contact - contact ≥ 5,5 mm Double and reinforced insulation between contacts • Low rated power consumption • High voltage resistance ≥ 4 kV at contamination level 2 • High mechanical service life • Compact size, small height

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • Clearance and creepage distances: contact-coil ≥ 8 mm version OA 5667.16 with double and reinforced insulation • Low rated power consumption • High mechanical service life • Compact size, small height

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Verified by Europages

Germany

Verified by Europages

Germany

Verified by Europages

Germany

Verified by Europages

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3, DIN EN 45545 (fire protection on railway vehicles) • With forcibly guided contacts • Safe separation betwenn coil/contact and contact/contact for applications at pollution degree 2 with rated insulation voltage 250 V • Clearance and creepage distances contact - coil ≥ 5.5 mm contact - contact ≥ 5.5 mm • Low nominal and holding power • High mechanical service life • Extremly smallest height only 10.3 mm and minimum area • RoHS compliance • Placing SMD components between PCB and relay is possible

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • High switching reliability due to crown contacts • Clearance and creepage distances: contact - coil ≥ 8 mm contact - contact ≥ 5.5 mm Double and reinforced insulation with pollution degree 2 Overvoltage category: III • High voltage resistance ≥ 4 kV • High mechanical service life • High temperature range at OA 5601 and OA 5602: -40 ... +85°C at OA 5603: -40 ... +75°C • High continiuous thermal current Ith = 10 A • High voltage range 0.7 ... 1.6 UN • As option wash proof RT III

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • Clearance and creepage distances: contact - contact ≥ 5,5 mm • Low rated power consumption and holding power • High mechancial service life • High temperature range • High thermal continuous current • 15,5 mm height • Version with double contacts possible, AgNi 0.15 + 5 μm Au-contacts

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • High switching reliability due to crown contacts • Low rated power consumption • High mechanical service life • Compact size • Optionally wash proof

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • double and reinforced insulation between contact sets acc. to EN 50178 • High dielectric strength • High mechanical service life • High switching reliability • Compact size • High thermal continuous current • High voltage range • Wash proof model as option

Request for a quote

Germany

Verified by Europages

• According to DIN EN 61810-1, DIN EN 61810-3 • With forcibly guided contacts • Clearance and creepage distances contact-coil ≥ 8 mm, contact - contact ≥ 5.5 mm Double and reinforced insulation between contact sets • Low rated power consumption • High mechanical service life • Compact size, small height • Wash proof model as option

Request for a quote

Germany

Verified by Europages

Germany

Verified by Europages

Request for quotes

Create one request and get multiple quotes form verified suppliers.

  • Only relevant suppliers
  • Data privacy compliant
  • 100% free