The screw-in transmitter LMK 351 has been designed for measuring small system pressure and level measurement in container. The LMK 351 is based on an own-developed capacitive ceramic sensor element. Usage in viscous and pasty media is possible because of the flush mounted sensor. For the usage in aggressive media a pressure port in PVDF and the diaphragm in AI2O3 99.9 % is available. An intrinsically safe version complete the range of possibilities. Features — nominal pressure: 0 ... 40 mbar up to 0 ... 20 bar — accuracy: 0.35 % (opt. 0.25 %) FSO — pressure port G 1 1/2" for pasty and polluted media Optional Features — IS-version Ex ia = intrinsically for gases and dusts — pressure port PVDF for aggressive media — diaphragm pure ceramic (99,9 % Al2O3) — customer specific versions

Request for a quote

Germany

Verified by Europages

The detachable plastic submersible probe LMK 808 was developed for level measurement in water and wastewater. The basis of the probe is an extremely robust, almost maintenance-free capacitive ceramic sensor. For level measurement in river courses, on weir systems or in locks, great emphasis was placed on overvoltage / lightning protection. In addition, the cable can be protected against bites if necessary. The sensor head can be separated from the cable part and can therefore be replaced if necessary without time-consuming assembly work. Features: — nominal pressure: 0 ... 1 mH2O bis 0 ... 100 mH2O — accuracy: 0.35 % (opt. 0.25 %) FSO — diameter 35 mm — diaphragm ceramics Al2O3 (99.9 %) — excellent long term stability — integrated lightning protection 8 kA gas discharge tube (8/20µsec); 4 kV surge l-l/l-e according to EN61000-4-5 Optional Features: — mounting accessories — different kinds of elastomer

Request for a quote

Germany

Verified by Europages

The separable plastic immersion probe LMK 858 was designed for level measurement in aggressive media, desalination plants and for use in more viscous media such as sludge. Since the area of application is often outside a building, great emphasis was placed on high surge / lightning protection. The immersion probe is based on an extremely robust and precise pressure sensor, the membrane of which consists of a high-purity ceramic. Another special feature of the LMK 858 is the separability of the probe head and cable part. Features: — nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O — accuracy: 0.35 % (opt. 0.25 %) FSO — diameter 45 mm — chemical resistance — housing PP-HT — integrated lightning protection and increased overvoltage protection; 8 kA gas discharge tube (8/20 μsec); 4 kV surge l-l/l-e according to EN61000-4-5 Optional Features: — cable protection — diaphragm pure ceramic (99.9 % AI2O3)

Request for a quote

Germany

Verified by Europages

The LMK 458 has been developed for measuring level in service and storage tanks and is as a consequence certificated for shipbuilding and offshore applications. A permissible operating temperature of up to 125 °C and the possibility to use the device in intrinsic safe areas enable to measure the pressure of various fluids under extreme conditions. The basis for the LMK 458 is a capacitive ceramic sensor element designed by BD\SENSORS, which offers a high overload resistance and medium compatibility. Features: — nominal pressure: 0 ... 40 cmH2O up to 0 ... 200 mH2O — accuracy: 0.35 % (opt. 0.1 %) FSO — diameter 39.5 mm — high overpressure capability — high long term stability — shipping approvals: ABS, BV, CCS, DNV, GL, LR Optional Features: — IS-version — diaphragm pure ceramic (99.9% AI2O3) — different housing materials (stainless steel, CuNiFe) — screw-in and flange version — accessoires

Request for a quote

Germany

Verified by Europages

The separable stainless steel probe LMP 308 is designed for the continually level measurement of water and thin fluids. In order to facilitate stock-keeping and mainten-ance the transmitter head is plugged to the cable assembly with a connector and can be changed easily. Features: — nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O — accuracy: 0.35 % (opt. 0.25% / 0.1 %) FSO — diameter 35 mm — cable and sensor section separable — excellent long term stability — high accuracy Optional Features: — IS-version Ex ia = intrinsically safe for gas and dust — SIL 2 (Safety integrity level) — customer specific versions — mounting accessoires as cable gland and terminal clamp of stainless steel — different kinds of cables — different kinds of seal materials

Request for a quote

Germany

Verified by Europages

The slimline probe LMP 305 with silicon stainless steel sensor is designed for continous level measurement in confined space conditions. Permissible media are clean or waste water and thin fluids. A piezoresistiv stainless steel sensor with low thermal error, an excellent linearity and a long term stability, is basis of LMP 305. Features: — nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O — accuracy: 0,35 % (opt. 0,25 %) FSO — diameter 19 mm for cramped areas e.g. 1" observation well — small thermal effect — excellent linearity — excellent long term stability Optional Features: — different kinds of cable — customer specific versions e.g. special pressure ranges

Request for a quote

Germany

Verified by Europages

The plastic submersible probe LMK 807 is designed for continous level measurement for waste water or and different aggressive media. Basic element of the plastic submersible probe is the flush mounted ceramic sensor, which makes cleaning easier when solid parts of the medium deposit on it. Different cable and elastomer materials are available in order to achieve maximum media compatibility. Features: — nominal pressure: 0 ... 4 mH2O up to 0 ... 100 mH2O# — accuracy: 0.5 % FSO — diameter 35 mm — excellent long term stability — easy handling Optional Features: — SIL 2 (safety integrity level) according to IEC 61508 / IEC 61511 — different kinds of cables and elastomeres — customer specific version e.g. special pressure ranges

Request for a quote

Germany

Verified by Europages

The separable stainless steel probe LMK 358H has been designed for level measurement in waste water, waste and higher viscosity media. Basic element is a capacitive ceramic sensor. In order to facilitate stock-keeping and maintenance the transmitter head is plugged to the cable assembly with a connector and can be changed easily. Features: — nominal pressure range 0 ... 60 cmH2O up to 0 ... 100 mH2O — accuracy: 0.1 % — diameter 39.5 mm — cable and sensor section separable — HART®-communication (setting of offset. span and damping) — permissible temperatures up to 85 °C — high long term stability Optional Features: — IS-version Ex ia = intrinsically safe for gas and dust — cable protection via corrugated pipe — diaphragm (AI2O3 99.9 %) — accessories e.g. mounting flange with cable gland and terminal clamp

Request for a quote

Germany

Verified by Europages

The stainless steel probe LMK 387 was developed for level and gauge measurement in wastewater, sludge or water courses. The mechanical robustness of the front-flush ceramic diaphragm faciliates an easy disassembly and cleaning of the probe in case of service. Compared to the level probe LMK 382 the outside-diameter is only 22 mm, which allows an easy installation and backfitting in 1" tubes or in cramped fitting conditions. An IS-version is also available. Features: — nominal pressure: from 0 ... 4 mH2O up to 0 ... 100 mH2O — accuracy: 0.35 % (opt. 0.25 %) FSO — diameter 22 mm — diaphragm ceramics 99.9% Al2O3 (on request) — highly appropriated for wastewater, sludge and viscous media Optional Features: — IS-version — housing material titanium — drinking water certificate according to DVGW and KTW — temperature element Pt 100 — mounting with stainless steel tube — different kinds of cables and elastomers

Request for a quote

Germany

Verified by Europages

The stainless steel probe DCL 551 with RS485 in-terface uses the communication protocol Modbus RTU which has found the way in industrial communication as an open protocol. The Modbus protocol is based on a master slave architecture with which up to 247 slaves can be questioned by a master – the data are transferred in binary form. DCL 551 has been designed for hydrostatic level measurement in sewage as well as for viscous and pasty media. Basic element is a robust and high overpressure capable capacitive ceramic sensor. Features — Nominal pressure: from 0 ... 40 cmH2O up to 0 ... 200 mH2O — accuracy: 0.35 % (opt. 0.25 %) FSO — output signal: RS485 with Modbus RTU protocol — diameter 39.5 mm — excellent long term stability — especially for sewage, viscous and pasty media Optional features: — diaphragm ceramics Al2O3 99,9%

Request for a quote

Germany

Verified by Europages

The DCL 571 with RS485 interface uses the communication protocol Modbus RTU which has found the way in industrial communication as an open protocol. The Modbus protocol is based on a master slave architecture with which up to 247 slaves can be questioned by a master – the data will transfer in binary form. The probe was developed for level measurement in waste water, sludge or water courses. The mechanical robustness of the flush ceramic diaphragm facilitates an easy disassembly and cleaning of the probe in case of service. The outside-diameter is only 22 mm for easy installation and back fitting in 1″ tubes or in cramped fitting conditions Features — Nominal pressure from 0 ... 1 mH2O up to 0 ... 100 mH2O — accuracy: 0.35% (opt. 0.35 %) FSO — output signal: RS485 with Modbus RTU protocol — diameter 22 mm — highly appropriated for sewage water Optional features — drinking water certificate according to DVGW and KTW

Request for a quote

Germany

Verified by Europages

The stainless steel probe DCL 531 with RS485 interface uses the communication protocol Modbus RTU which has found the way in industrial communication as an open protocol. The Modbus protocol is based on a master Slave architecture with which up to 247 Slaves can be questioned by a master – the data are transferred in binary form. Basic element is a high quality stainless steel sensor with high requirements for exact measurement with excellent long term stability. Features — nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O — accuracy: 0.25 % FSO — output signal: RS485 with Modbus RTU protocol — diameter diameter 26.5 mm — small thermal effect small thermal effect — high accuracy excellent accuracy — reset function Optional Features — drinking water certificate according to DVGW and KTW — different kinds of cables — different kinds of seal materials

Request for a quote

Germany

Verified by Europages

The stainless steel probe LMP 307 is designed for continuous level measurement in water and clean or waste fluids. Basic element is a high quality stainless steel sensor with high requirements for exact measurement with excellent long term stability. Features: — nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O — accuracy: 0,35 % (opt. 0,25% / 0,1 %) FSO — diameter 26,5 mm — small thermal effect — excellent long term stability — high accuracy Optional Features: — IS-version Ex ia = intrinsically safe for gas and dust — SIL 2 (safety integrity level) — drinking water certificate acc. to DVGW and KTW — different kinds of cables and elastomers — petrol version, welded pressure sensor and housing — mounting with stainless steel pipe

Request for a quote

Germany

Verified by Europages

The capacitive level sensor BEDIA NR 150 is suitable for liquids with low relative dielectric constant εr 1,8 … 6 (ref. εr 2,1). It has a MIN/MAX selector switch and the functions for MIN or MAX monitoring as well as other properties (output signal LSS or HSS, response delay etc.) are factory pre-set. The switch point is adjustable by means of a teach-in momentary switch.

Request for a quote

Germany

Verified by Europages

The capacitive level sensor NR 160 is designed to monitor liquids and powders with high relative dielectric constant εr 35 … 85. The functions for MIN or MAX monitoring as well as other properties (output signal LSS or HSS, response delay etc.) are factory pre-set. The switch point is adjustable by means of a teach-in momentary switch.

Request for a quote

Germany

Verified by Europages

The NR 260 is a capacitive level sensor for monitoring liquids. It is designed for use in fuel cells. The material is also suited to applications in the chemical industry for monitoring aggressive media. The functions for MIN or MAX monitoring as well as other properties (output signal LSS or HSS, response delay etc.) are factory pre-set. The Main Features of the NR 260 are high medium resistance of materials enamel, Hastelloy C4 2.4610 and stainless steel 1.4571 high protection class IP67 with connector short-circuit proof switching output 1 A, high side or low side switch MAX sensor or MIN sensor switch point factory pre-set for the following media: de-ionised water (conductivity < 4,2 μS/cm): 28 mm ± 2 mm tap water (conductivity ≈ 300 μS/cm): 22 mm ± 2 mm other media upon request; switch point adjustment via programmable interface on request

Request for a quote

Germany

Verified by Europages

BEDIA level monitoring sensors are used to monitor the filling levels of liquids. The sensors detect when a filling level is exceeded or falls below a limit. Water-based liquids like coolants, AdBlue®, fresh water, waste water, bilge water and oil-based liquids like motor oils, hydraulic oils, fuels and brake fluids can be monitored. Since they contain no mechanical moving parts, their function will not be influenced by dirt particles or other influences. No electrical current is sent through the medium via an electrode with BEDIA sensors, an electrolysis of the medium is not possible. Operating Principle The function of the sensor is based on the capacitive principle. It detects the change in capacitance that occurs when an electrode surrounded by air is immersed into a liquid medium. This change in capacitance at the electrode of the sensor excites an oscillator. This signal is processed by a microcontroller-based evaluation circuit which activates or deactivates an output stage.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Verified by Europages

BEDIA level monitoring sensors are used to monitor the filling levels of liquids. The sensors detect when a filling level is exceeded or falls below a limit. Water-based liquids like coolants, AdBlue®, fresh water, waste water and oil-based liquids like motor oils, hydraulic oils, fuels and brake fluids can be monitored. Operating Principle The function of the sensor is based on the capacitive principle. It detects the change in capacitance that occurs when an electrode surrounded by air is immersed into a liquid medium. This change in capacitance at the electrode of the sensor excites an oscillator. This signal is processed by a microcontroller-based evaluation circuit which activates or deactivates an output stage. Types of Media The level monitoring sensors are designed for two different media types: For electrically conductive liquid media with relative permittivity within a range of εr 35 … 85 (water, coolant, water/glycol mixture) For electrically non-conductive liquid media

Request for a quote

Germany

Verified by Europages

Areas of Application and Advantages BEDIA CLS 10 stands for special versions of our well-proven CLS 40 series for heavy duty applications. Currently, the BEDIA CLS 10 series includes a variety of sensors, which are compatible replacement parts for level switches from Cooper Standard and Robert Shaw which are obsolete nowadays – and this in well proven BEDIA quality. This also includes sensors with 2 complementary CMOS outputs. It should be emphasized that the water sensors with two complementary outputs can be operated with a supply voltage of 4.75 V DC – 32 V DC. Operating Principle The function of the sensor is based on the capacitive principle. It detects the change in capacitance that arises when an electrode surrounded by air is immersed into a liquid medium. This change in capacitance at the electrode of the sensor excites an oscillator, causing it to oscillate (at a frequency of approx. 600 kHz). Then this signal is processed by a microprocessor-based evaluation circuit.

Request for a quote

Germany

Verified by Europages

The precision screw-in transmitter LMP 331i demonstrate the further development of our industrial pressure transmitters. The signal processing of sensor signal is done by digital electronics with 16-bit analog digital converter. Consequently it is possible to conduct an active compensation and the transmitters with excellent maesurements and exeptionally attractive price to offer on the market. Features — nominal pressure: 0 ... 400 mbar up to 0 ... 40 bar — accuracy: 0.1 % FSO — thermal error in compensated range -20 … 80 °C: 0.2 % FSO TC 0.02 % FSO / 10 K — turn-down 1:10 — communication interface for adjusting of offset, span and damping Optional Features — IS-version Ex ia = intrinsically safe for gases and dusts — adjustment of nominal pressure gauges (factory-provided)

Request for a quote

Germany

Verified by Europages

The TLS 100 tube sensor works on the capacitive measuring principle and detects the presence of a liquid in a plastic tube. These plastic tubes may also be mounted as a by-pass on a compensator in order to signal the required medium level in containers. The sensor is simply snapped onto the tube at the ideal level of the medium and provides versatile usage for a wide range of applications in medical equipment, the food stuffs industry etc. The sensor can additionally be fixed by means of the two mounting lugs to ensure a tight fit on the tube. Caution The switch point is factory pre-set so as to lie exactly between the two mounting clips. When readjusting the switch point, please observe that it again lies between the two clips. A mass surface in the proximity (< 10 mm) may influence the switch point and may necessitate a readjustment.

Request for a quote

Germany

Verified by Europages

BEDIA intelligent tank sensor ITS 60 is used to monitor the filling levels of Diesel fuels. The sensor is able to automatically recognize what kind of Diesel fuel (Bio-Diesel, Summer-/Winter-Diesel etc.) is present and calibrates itself to it. The capacitative measurement principle permits measurement of levels without mechanically moving parts. This considerably increases stability and operating safety. Mechanics The new tank sensor ITS 60 is characterized by a particularly stable, but light mechanical system specially designed for “Heavy Duty Applications”. The mounting flange and measurement tube are constructed from die cast aluminium. This construction permits the insertion of tank sensors up to 1200 mm in length, without additional support on the tank floor. The flange hole distribution is compatible with commercially used tank sensors. This means that this system can be used without expensive conversions.

Request for a quote

Germany

Verified by Europages

Laser distance sensors optoNCDT ILR103x/LC1 are designed for fast displacement measurement between 0.2 and 15m or rather up to 50m with reflector. The fast response time of 10ms is typical for this series. With buttons at the quite small housing a Teach-In or the assignment of switching points can be done quickly. Tasks of this sensors are fill level measurement, positioning or length measurements.

Request for a quote

Germany

Verified by Europages

▪ Continuous volumetric and pulsation-free dosing regardless of viscosity ▪ For low viscosity and self-levelling materials (e.g. trickle resins) ▪ Low wear solution due to avoidance of material contact at shaft seal ▪ Uninterrupted production thanks to material reservoir with up to 350 ml usable volume ▪ Pressure and temperature sensor including sensor holder at pump outlet ▪ Level programmable using analog level sensor ▪ Filling under atmospheric pressure ▪ Optional connection for process gas (max. 0.2 bar pressure) ▪ Dispenser holder for easy and stable installation ▪ Increased process reliability due to integrated safety device ▪ Dividable rotor assembly for easy & fast replacement and low spare part costs

Request for a quote

Germany

Verified by Europages

The LMP 308i is designed for continuous fill level and level measurement of water and liquid mediums. The signal processing of sensor signal is done by digital electronics with 16-bit analog digital converter. Consequently it is possible to conduct an active compensation of sensor intrinsic deviations from normal condions like nonlinearity and thermal error. In order to facilitate stock-keeping and maintenance the transmitter body is plugged to the cable assembly with a connector and can be changed easily. Features: — nominal pressure: 0 ...4 mH2O up to 0...200 mH2O — accuracy: 0.1 % FSO — diameter 35 mm — cable and sensor section separable — thermal error in compensated range -20...70°C: 0.2 FSO TC 0.02% FSO/10K 0,02 % FSO / 10K — high accuracy — communication connection — turn-down 1:10 Optional Features: — IS-version — mounting accessories as cable gland and terminal clamp in stainless steel

Request for a quote

Germany

Verified by Europages

The screw-in transmitter LMP 331 has been designed for continuous level measurement and is characterized by an excellent performance and a robust construction. The modular construction allows the user the highest possible flexibility in the adaption of LMP 331. Optional features like e.g. an intrinsically safe version or a functionally safe version (SIL 2) increase the advantages when launching and realizing projects for plants and systems. Features — nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar — accuracy: 0.35 % (opt. 0.25% / 0.1 %) FSO — small thermal effect — excellent long term stability — pressure port G 3/4" flush Optional Features — IS-version Ex ia = intrinsically safe for gases and dusts — SIL 2 application according to IEC 61508 / IEC 61511 — different electrical connections — customer specific versions e.g. special pressure ranges

Request for a quote

Germany

Verified by Europages

The LMK 806 with ceramic sensor and diameter from only 21 mm has been especially designed for the continuous level measurement at confined space conditions. Permissible media are waste water or and different aggressive media. Basic element of the plastic submersible probe is the flush mounted ceramic sensor, which makes cleaning easier when solid parts of the medium deposit on it. Different cable and elastomer materials are available in order to achieve maximum media compatibility. Features: — nominal pressure: from 0 ... 6 mH2O up to 0 ... 200 mH2O — accuracy: 0.5 % FSO — diameter 21 mm — excellent linearity — excellent long term stability — suitable for hydrostatic level measurement e.g. 3/4" pipes Optional Features: — different cable materials — customer specific versions, e.g. special pressure rang

Request for a quote

Germany

Verified by Europages

The slimline probe LMK 306 with ceramic sensor has been especially designed for the continuous level measurement at confined space conditions. Permissible media are clean or slightly contaminated water and thin fluids. Different cable sheath materials are available in order to achieve maximum media compatibility. Features: — nominal pressure: 0 ... 6 mH2O up to 0 ... 200 mH2O — accuracy: 0.5 % FSO — diameter 17 mm — excellent long term stability — suitable for hydrostatic level measurement e.g. 3/4" pipes — excellent linearity Optional Features: — different cable materials — customer specific versions e.g. special pressure ranges Preferred areas of use: — level measurement at confined space conditions — ground water monitoring — depth or level measurement in wells — drinking water abstraction — level measurement in open and closed tanks

Request for a quote

Germany

Verified by Europages

The screw-in transmitter LMK 331 has been especially designed for level and process measurement and is suitable for pressure measurement of liquids, oils and gases. Usage in more viscous or polluted media is possible because of the semi-flush pressure sensor. For the usage in aggressive media we recommended the version with PVDF pressure port. Additional features like e.g. an intrinsically safe version or a functionally safe version (SIL 2) complete the range of possibilities. Features — nominal pressure: 0 ... 400 mbar up to 0 ... 60 bar — accuracy: 0.5 % FSO — pressure port G 3/4" flush Optional Features — IS-version (only for 4... 20 mA / 2-wire): Ex ia = intrinsically safe for gases and dusts — SIL 2 application according to IEC 61508 / IEC 61511 — pressure port PVDF for aggressive media — different electrical and mechanical connections — customer specific versions

Request for a quote

Request for quotes

Create one request and get multiple quotes form verified suppliers.

  • Only relevant suppliers
  • Data privacy compliant
  • 100% free