• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • level sensors

Results for

Level sensors - Import export

Manufacturer/producer

Germany

Verified by Europages

The PR 6251 fill-level sensor is specially designed for basic weighing of silos and horizontal tanks. It meets all requirements for years of trouble-free operation without adjustment. For use in EX zones 1, 2, 20, 21, 22 and DIV 1. Ultra-flat load cell for low precision tank weighing as alternative to level sensors Load cell capacity range from 500 kg to 16 t Accuracy class: L (0.5 %) Corresponding mounting kit: PR 6051

Request for a quote

Germany

Verified by Europages

For oil, petrol, diesel fuels

Request for a quote

Switzerland

Verified by Europages

The high-precision multi-parameter probes of the 36XiW-CTD series measure conductivity and temperature as well as pressure, along with the depth of bodies of water. Temperature dependence and nonlinearity are precisely compensated for in the microcontroller by means of a mathematical model. The integrated Pt1000 achieves an accuracy of ±0,1 °C, and the conductivity can be measured at ± 2,5% of the selected range (0,2 / 2 / 20 / 200 mS/cm). The sensors can be supplied with either an RS485 or SDI-12 interface. Extended lightning protection comes as standard with the SDI-12 and is available as an option for the RS485 interface.

Request for a quote

Switzerland

Verified by Europages

The level sensors of the 46X-Ei series combine a ceramic measuring cell for very low measuring ranges on the mbar scale with microprocessor electronics for compensating for temperature dependence and nonlinearity. In addition to the digital RS485 interface, the sensors also have a rangeable analog output. Intrinsically safe – suitable for use in explosive atmospheres.

Request for a quote

Switzerland

Verified by Europages

The level sensors of the 26Y-Ei series are budget-friendly, but still offer high accuracy and excellent long-term stability. They are available in versions for absolute or relative pressure. With a start-up time of just 5 ms, the Y line is ideally suited to data logger applications. Intrinsically safe – suitable for use in explosive atmospheres.

Request for a quote

Switzerland

Verified by Europages

The level sensors of the 46X series combine a ceramic measuring cell for very low measuring ranges on the mbar scale with microprocessor electronics for compensating for temperature dependence and nonlinearity. In addition to the digital RS485 interface, the sensors also have a rangeable analog output.

Request for a quote

Switzerland

Verified by Europages

The 36KyX series was specially developed for brackish water and sewage applications. It is equipped with a non-fouling Kynar separating diaphragm, which combines the anti-adhesion properties of PTFE with outstanding hardness and abrasion resistance. This level sensors design can be readily installed in harsh environments, eliminating the need for bulky, costly protective equipment. In addition to the RS485 interface, the measurement results can also be output via the integrated D/A converter as a rangeable analog signal.

Request for a quote

Switzerland

Verified by Europages

The level sensors of the 26Y series are budget-friendly, but still offer high accuracy and excellent long-term stability. They are available in versions for absolute or relative pressure. With a start-up time of just 5 ms, the Y line is ideally suited to data logger applications.

Request for a quote

Switzerland

Verified by Europages

With a small diameter of just 16 mm, these level sensors are ideally suited to use in small spaces, such as narrow monitoring pipes. The measurement results can be read out via the 4...20 mA output or the RS485 interface. Extended lightning protection is integrated as standard.

Request for a quote

Germany

Verified by Europages

The screw-in transmitter LMK 351 has been designed for measuring small system pressure and level measurement in container. The LMK 351 is based on an own-developed capacitive ceramic sensor element. Usage in viscous and pasty media is possible because of the flush mounted sensor. For the usage in aggressive media a pressure port in PVDF and the diaphragm in AI2O3 99.9 % is available. An intrinsically safe version complete the range of possibilities. Features — nominal pressure: 0 ... 40 mbar up to 0 ... 20 bar — accuracy: 0.35 % (opt. 0.25 %) FSO — pressure port G 1 1/2" for pasty and polluted media Optional Features — IS-version Ex ia = intrinsically for gases and dusts — pressure port PVDF for aggressive media — diaphragm pure ceramic (99,9 % Al2O3) — customer specific versions

Request for a quote

Germany

Verified by Europages

The detachable plastic submersible probe LMK 808 was developed for level measurement in water and wastewater. The basis of the probe is an extremely robust, almost maintenance-free capacitive ceramic sensor. For level measurement in river courses, on weir systems or in locks, great emphasis was placed on overvoltage / lightning protection. In addition, the cable can be protected against bites if necessary. The sensor head can be separated from the cable part and can therefore be replaced if necessary without time-consuming assembly work. Features: — nominal pressure: 0 ... 1 mH2O bis 0 ... 100 mH2O — accuracy: 0.35 % (opt. 0.25 %) FSO — diameter 35 mm — diaphragm ceramics Al2O3 (99.9 %) — excellent long term stability — integrated lightning protection 8 kA gas discharge tube (8/20µsec); 4 kV surge l-l/l-e according to EN61000-4-5 Optional Features: — mounting accessories — different kinds of elastomer

Request for a quote

Germany

Verified by Europages

The separable plastic immersion probe LMK 858 was designed for level measurement in aggressive media, desalination plants and for use in more viscous media such as sludge. Since the area of application is often outside a building, great emphasis was placed on high surge / lightning protection. The immersion probe is based on an extremely robust and precise pressure sensor, the membrane of which consists of a high-purity ceramic. Another special feature of the LMK 858 is the separability of the probe head and cable part. Features: — nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O — accuracy: 0.35 % (opt. 0.25 %) FSO — diameter 45 mm — chemical resistance — housing PP-HT — integrated lightning protection and increased overvoltage protection; 8 kA gas discharge tube (8/20 μsec); 4 kV surge l-l/l-e according to EN61000-4-5 Optional Features: — cable protection — diaphragm pure ceramic (99.9 % AI2O3)

Request for a quote

Germany

Verified by Europages

The LMK 458 has been developed for measuring level in service and storage tanks and is as a consequence certificated for shipbuilding and offshore applications. A permissible operating temperature of up to 125 °C and the possibility to use the device in intrinsic safe areas enable to measure the pressure of various fluids under extreme conditions. The basis for the LMK 458 is a capacitive ceramic sensor element designed by BD\SENSORS, which offers a high overload resistance and medium compatibility. Features: — nominal pressure: 0 ... 40 cmH2O up to 0 ... 200 mH2O — accuracy: 0.35 % (opt. 0.1 %) FSO — diameter 39.5 mm — high overpressure capability — high long term stability — shipping approvals: ABS, BV, CCS, DNV, GL, LR Optional Features: — IS-version — diaphragm pure ceramic (99.9% AI2O3) — different housing materials (stainless steel, CuNiFe) — screw-in and flange version — accessoires

Request for a quote

Germany

Verified by Europages

The separable stainless steel probe LMP 308 is designed for the continually level measurement of water and thin fluids. In order to facilitate stock-keeping and mainten-ance the transmitter head is plugged to the cable assembly with a connector and can be changed easily. Features: — nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O — accuracy: 0.35 % (opt. 0.25% / 0.1 %) FSO — diameter 35 mm — cable and sensor section separable — excellent long term stability — high accuracy Optional Features: — IS-version Ex ia = intrinsically safe for gas and dust — SIL 2 (Safety integrity level) — customer specific versions — mounting accessoires as cable gland and terminal clamp of stainless steel — different kinds of cables — different kinds of seal materials

Request for a quote

Germany

Verified by Europages

The slimline probe LMP 305 with silicon stainless steel sensor is designed for continous level measurement in confined space conditions. Permissible media are clean or waste water and thin fluids. A piezoresistiv stainless steel sensor with low thermal error, an excellent linearity and a long term stability, is basis of LMP 305. Features: — nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O — accuracy: 0,35 % (opt. 0,25 %) FSO — diameter 19 mm for cramped areas e.g. 1" observation well — small thermal effect — excellent linearity — excellent long term stability Optional Features: — different kinds of cable — customer specific versions e.g. special pressure ranges

Request for a quote

Germany

Verified by Europages

The plastic submersible probe LMK 807 is designed for continous level measurement for waste water or and different aggressive media. Basic element of the plastic submersible probe is the flush mounted ceramic sensor, which makes cleaning easier when solid parts of the medium deposit on it. Different cable and elastomer materials are available in order to achieve maximum media compatibility. Features: — nominal pressure: 0 ... 4 mH2O up to 0 ... 100 mH2O# — accuracy: 0.5 % FSO — diameter 35 mm — excellent long term stability — easy handling Optional Features: — SIL 2 (safety integrity level) according to IEC 61508 / IEC 61511 — different kinds of cables and elastomeres — customer specific version e.g. special pressure ranges

Request for a quote

Germany

Verified by Europages

The separable stainless steel probe LMK 358H has been designed for level measurement in waste water, waste and higher viscosity media. Basic element is a capacitive ceramic sensor. In order to facilitate stock-keeping and maintenance the transmitter head is plugged to the cable assembly with a connector and can be changed easily. Features: — nominal pressure range 0 ... 60 cmH2O up to 0 ... 100 mH2O — accuracy: 0.1 % — diameter 39.5 mm — cable and sensor section separable — HART®-communication (setting of offset. span and damping) — permissible temperatures up to 85 °C — high long term stability Optional Features: — IS-version Ex ia = intrinsically safe for gas and dust — cable protection via corrugated pipe — diaphragm (AI2O3 99.9 %) — accessories e.g. mounting flange with cable gland and terminal clamp

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Verified by Europages

The stainless steel probe DCL 551 with RS485 in-terface uses the communication protocol Modbus RTU which has found the way in industrial communication as an open protocol. The Modbus protocol is based on a master slave architecture with which up to 247 slaves can be questioned by a master – the data are transferred in binary form. DCL 551 has been designed for hydrostatic level measurement in sewage as well as for viscous and pasty media. Basic element is a robust and high overpressure capable capacitive ceramic sensor. Features — Nominal pressure: from 0 ... 40 cmH2O up to 0 ... 200 mH2O — accuracy: 0.35 % (opt. 0.25 %) FSO — output signal: RS485 with Modbus RTU protocol — diameter 39.5 mm — excellent long term stability — especially for sewage, viscous and pasty media Optional features: — diaphragm ceramics Al2O3 99,9%

Request for a quote

Germany

Verified by Europages

The DCL 571 with RS485 interface uses the communication protocol Modbus RTU which has found the way in industrial communication as an open protocol. The Modbus protocol is based on a master slave architecture with which up to 247 slaves can be questioned by a master – the data will transfer in binary form. The probe was developed for level measurement in waste water, sludge or water courses. The mechanical robustness of the flush ceramic diaphragm facilitates an easy disassembly and cleaning of the probe in case of service. The outside-diameter is only 22 mm for easy installation and back fitting in 1″ tubes or in cramped fitting conditions Features — Nominal pressure from 0 ... 1 mH2O up to 0 ... 100 mH2O — accuracy: 0.35% (opt. 0.35 %) FSO — output signal: RS485 with Modbus RTU protocol — diameter 22 mm — highly appropriated for sewage water Optional features — drinking water certificate according to DVGW and KTW

Request for a quote

Germany

Verified by Europages

The stainless steel probe DCL 531 with RS485 interface uses the communication protocol Modbus RTU which has found the way in industrial communication as an open protocol. The Modbus protocol is based on a master Slave architecture with which up to 247 Slaves can be questioned by a master – the data are transferred in binary form. Basic element is a high quality stainless steel sensor with high requirements for exact measurement with excellent long term stability. Features — nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O — accuracy: 0.25 % FSO — output signal: RS485 with Modbus RTU protocol — diameter diameter 26.5 mm — small thermal effect small thermal effect — high accuracy excellent accuracy — reset function Optional Features — drinking water certificate according to DVGW and KTW — different kinds of cables — different kinds of seal materials

Request for a quote

Germany

Verified by Europages

The stainless steel probe LMP 307 is designed for continuous level measurement in water and clean or waste fluids. Basic element is a high quality stainless steel sensor with high requirements for exact measurement with excellent long term stability. Features: — nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O — accuracy: 0,35 % (opt. 0,25% / 0,1 %) FSO — diameter 26,5 mm — small thermal effect — excellent long term stability — high accuracy Optional Features: — IS-version Ex ia = intrinsically safe for gas and dust — SIL 2 (safety integrity level) — drinking water certificate acc. to DVGW and KTW — different kinds of cables and elastomers — petrol version, welded pressure sensor and housing — mounting with stainless steel pipe

Request for a quote

Czech Rep.

DUT-E fuel level sensors are used for accurate fuel level and volume measurement in tanks of vehicles and stationary units. DUT-E allows to determine current fuel volume and change in volume (refuelling or draining) of fuel in the tank.

Request for a quote

Turkey

Level Indicators are designed for electric signalling by rotary action of minimum or maximum material level inside bins, hoppers or silos.

Request for a quote

United Kingdom

DWL-2000XY, DWL-3000XY & DWL-3500XY are 2-Axis precision Digital Levels with high accuracy and wide measuring range of levelling, angle, alignment & vibration measurements, capable of real-time remote USB/wireless measurement & data logging. The accuracy performance is verified by accredited calibration & test bodies in USA, Japan & Germany traceable to NIST, JIS & DIN. These instruments are exceptionally engineered to greatly simplifying the task of precision engineering professionals & tradesmen in installation, setting up & maintenance of very high precision CNC machines, test instruments & alignment-sensitive equipment.

Request for a quote

Germany

Verified by Europages

The capacitive level sensor BEDIA NR 150 is suitable for liquids with low relative dielectric constant εr 1,8 … 6 (ref. εr 2,1). It has a MIN/MAX selector switch and the functions for MIN or MAX monitoring as well as other properties (output signal LSS or HSS, response delay etc.) are factory pre-set. The switch point is adjustable by means of a teach-in momentary switch.

Request for a quote

Germany

Verified by Europages

The capacitive level sensor NR 160 is designed to monitor liquids and powders with high relative dielectric constant εr 35 … 85. The functions for MIN or MAX monitoring as well as other properties (output signal LSS or HSS, response delay etc.) are factory pre-set. The switch point is adjustable by means of a teach-in momentary switch.

Request for a quote

Germany

Verified by Europages

The NR 260 is a capacitive level sensor for monitoring liquids. It is designed for use in fuel cells. The material is also suited to applications in the chemical industry for monitoring aggressive media. The functions for MIN or MAX monitoring as well as other properties (output signal LSS or HSS, response delay etc.) are factory pre-set. The Main Features of the NR 260 are high medium resistance of materials enamel, Hastelloy C4 2.4610 and stainless steel 1.4571 high protection class IP67 with connector short-circuit proof switching output 1 A, high side or low side switch MAX sensor or MIN sensor switch point factory pre-set for the following media: de-ionised water (conductivity < 4,2 μS/cm): 28 mm ± 2 mm tap water (conductivity ≈ 300 μS/cm): 22 mm ± 2 mm other media upon request; switch point adjustment via programmable interface on request

Request for a quote

Germany

Verified by Europages

BEDIA level monitoring sensors are used to monitor the filling levels of liquids. The sensors detect when a filling level is exceeded or falls below a limit. Water-based liquids like coolants, AdBlue®, fresh water, waste water, bilge water and oil-based liquids like motor oils, hydraulic oils, fuels and brake fluids can be monitored. Since they contain no mechanical moving parts, their function will not be influenced by dirt particles or other influences. No electrical current is sent through the medium via an electrode with BEDIA sensors, an electrolysis of the medium is not possible. Operating Principle The function of the sensor is based on the capacitive principle. It detects the change in capacitance that occurs when an electrode surrounded by air is immersed into a liquid medium. This change in capacitance at the electrode of the sensor excites an oscillator. This signal is processed by a microcontroller-based evaluation circuit which activates or deactivates an output stage.

Request for a quote

Germany

Verified by Europages

BEDIA level monitoring sensors are used to monitor the filling levels of liquids. The sensors react when a filling level is exceeded or falls below a limit. Aqueous mediums like coolants, AdBlue®, fresh water, waste water, bilge water and oil-based liquids like motor oils, hydraulic oils, fuels and brake fluids can be monitored. Since they contain no mechanical moving parts, their function will not be influenced by dirt particles or other influences. No electrical current is sent through the medium via an electrode with BEDIA sensors, an electrolysis of the medium is not possible. Operating Principle The function of the sensor is based on the capacitive principle. It detects the change in capacitance that arises when an electrode surrounded by air is immersed into a liquid medium. This change in capacitance at the electrode of the sensor excites an oscillator, causing it to oscillate. Then this signal is processed by a microprocessor-based evaluation circuit.

Request for a quote

Request for quotes

Create one request and get multiple quotes form verified suppliers.

  • Only relevant suppliers
  • Data privacy compliant
  • 100% free