• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • heating radiators

Results for

Heating radiators - Import export

GermanyMunich, Nuremberg and Bavaria

Germany

Verified by Europages

Hazardous area radiators ATEX II 2 G/D EEx d IIC T6 ATEX The „FLR“ range of liquid filled, electrically heated radiators has been specifically designed for providing heating in zone 1 or 2 and zone 21 or 22 hazardous areas where airborne dust particles are of particular concern. Can be supplied with adjustable control thermostat.

Request for a quote

Germany

Verified by Europages

Lubrication of highly stressed chains, joints or slideways at higher temperatures For conveying systems running beneath radiated heat, in baking and drying lines in the foodstuffs industry Dry lubrication at operating temperatures above 200°C The synthetic oil content evaporates odorlessly without leaving residues, while the solid lubricant content are left behind to carry out dry lubrication Advantages and benefits Highly suitable as a high-temperature lubricant Highly effective due to homogeneous distribution of the finest graphite throughout the oil Versatile application as a liquid lubricant under high temperature conditions Resistant to water, chemicals, fuels, lubricants, and hydraulic oils NSF H1 registered For best results, clean the surfaces. Best way is to clean mechanically first and then with OKS 2610 or OKS 2611 universal cleaner. With a brush, drip oiler or by immersion or using a suitable automatic lubrication system, apply a sufficient quantity

Request for a quote

Germany

Verified by Europages

Lubrication of chains, fringe bearings, hinges, joints, clamping and drying frames or slideways at higher temperatures and loads For conveying systems under radiation heat in painting, stoving and drying systems Advantages and benefits Highly effective due to finest, homogeneous MoS₂ distribution in the oil Emergency running properties through MoS₂ at dry running Outstanding adhesion and lubrication effect with no tendency to drip or dry out Silicone-free For best adhesion, clean the surfaces. Best way is to clean mechanically first and then with OKS 2610 or OKS 2611 universal cleaner. With a brush, drip oiler or by immersion or using a suitable automatic lubrication system, apply a sufficient quantity to the locations to be lubricated. Allow excess to drip off. Allow OKS 350 to soak in before operating. Observe the machine manufacturer's instructions. Assess the lubrication frequency and quantity on basis of service conditions

Request for a quote

Germany

Verified by Europages

Lubrication of friction and rolling bearings, chains, joints or slideways at higher temperatures For conveying systems under radiation heat in painting, stoving and drying systems, travelling grates in firing systems Dry lubrication at temperatures above 200°C Lubrication of elastomers and plastics not resistant to mineral oil Advantages and benefits Highly suitable as a high-temperature lubricant Very effective due to finest, homogeneous MoS₂ distribution in the oil Resistant to water and many chemicals, fuels, lubricants and hydraulic oils For best adhesion, clean the surfaces. Best way is to clean mechanically first and then with OKS 2610/OKS 2611 universal cleaner. With a brush, drip oiler or by immersion or using a suitable automatic lubrication system, apply a sufficient quantity to the locations to be lubricated. If at all possible, avoid excess. Observe the machine manufacturer's instructions. Assess the lubrication frequency

Request for a quote

Germany

Statox 501 Infratox detects gases in the LEL and ppm range. Protecting people and assets from hydrocarbons The infrared absorption method of gas detection is ideal to detect hydrocarbons such as fuels. It features enough sensitivity to expand the range of application into the ppm range. For instance fuels such as gasoline, diesel or kerosene are mixtures of hydrocarbons. Infrared gas detection theory of operation Some gases absorb light at a certain wavelength (colour). This absorption band is specific to the gas. The rate of the absorption depends not only on the substance to be detected but also on the number of gas molecules (i.e. the concentration of the gas). This premise is used to detect gases. For example, the C - H bond in hydrocarbon molecules will oscillate and absorb light at 3, 4 mm. This fact makes it so easy to detect fuels. Hexane, for instance has 14 C - H bonds compared to Methane which has only 4! A light beam is directed through a cuvette filled with the gas to be detected. The more hydrocarbons are present, the more light will be absorbed. A photo detector at the other end of the cuvette measures the remaining light intensity. The difference between the original and remaining light intensity corresponds to the gas concentration. A reference beam with a different wavelength compensates for potential interferences of dust, humidity or variations of intensity from the light source. Fail-safe technology Failure of important components such as the light source or photo detector will trigger a "system fail" alarm. Most local authorities will accept this as a self-diagnostic feature. Systems including a self-check require less maintenance and calibration, saving time and money. Simple maintenance: Easy to read display and non-Vintrusive calibration The bright LED display of the Statox 501 Infratox shows the gas concentration in percent L.E.L. (Lower Explosion Limit). An important accessory is the calibration adapter, featuring control buttons operating Hall-sensors inside the Ex d housing. The service menu is password protected preventing unauthorised access. All parameters can be checked and changed, or a calibration can be done all without opening the transmitter. The adapter is also equipped with a gas outlet so that it can be used for flow-through applications. Impervious compact design The dimensions of the Statox 501 Infratox are small and compact. The sensor compartment is completely sealed, not allowing dust or insects to enter. It is located in the center of the sensor head. This allows heat radiation from the electronics and the infrared lamp to keep the unit a few degrees above the ambient temperature thus avoiding condensation. This innovative design makes any additional heating unnecessary, allowing the sensor head to be very energy efficient. This saves additional money by eliminating more expensive wiring and a bigger power supply that would otherwise be necessary. The sensor head is rated protection class IP 67 (6 = protection even against fine dust, 7 = submerged 1 m deep in water for 30 minutes). You can have confidence that this system will safely operate even in the harshest environment.

Request for a quote

Germany

ETC Source Four Zoom XT 150W 15°-30° white ETC combines the industrys standard Source Four Zoom optical system with a unique, waterlight housing to create the Source Four Zoom XT. Powered by the 12.000 hour Master ColorTM CDM lamp, Zook eX is rated IP 65 for exterior lighting use and is ideal for gobo / pattern projection and tight shutter cuts on specific structures or architectural details. The forward portion of the housing removes completely for beam sizing, focus, gobo insertion and shutter cut adjustments. The removable housing is designed to hang conveniently on the yoke, freeing both hands for focus. ETC Source Four 150W HID Zooms are supplied with Philips CDM Master Color 150W veramic metal halide lamp, colour frame and 1,8m cable without connector. Feature Physical Rugged, the cast and extruded aluminium construction unique waterlight exterior housing seal Precision extruded optical rails with positive lens position lock-down 20 gauge stainless steel shutters in a tri-plane assembly Roating shutter assembly +/- 25° slot for glass or stainless steel gobos / patterns waterlight electronic ballast housing Tilt-down ballast housing for convenient lamp change CE compliant Electrical » ≫ 150W electronic ballast (yoke mounted) » ≫ Less than 14 Amps inrush current, lasts less than one AC cycle (16.7mS) » ≫ Select breakers that meet or exceed the in-rush and ampacity requirement » ≫ Less than 10% Harmonic distortion » ≫ Greater than 95% Power Factor » ≫ 90% Ballast Efficiency » ≫ 230V ± 10%, 50-60Hz » ≫ 0.74A operating current Optical » ≫ Optimised optical system for improved photometric » ≫ performance and field uniformity » ≫ Faceted borosilicate reflector with dichroic cold mirror coating removes greater than 90% infrared radiation (heat) and reflects greater than 95% of visible light » ≫ Reflector and lenses secured with anti-vibration shock mounts » ≫ Two bi-convex lenses with anti-reflective coatings » ≫ Low gate and beam temperature, shutters will not warp or distort Lamp » ≫ 150W Ceramic metal halide150W Philips MasterColor ® CDM lamp » ≫ 3000 K colour temperature » ≫ 12,000 hrs. lamp life » ≫ Optional 150W Philips MasterColor CDM 4,200K colour temperature (96 CRI) lamp available » ≫ IP65 » ≫ mass: 78,5x27,6x25,9cm » ≫ beam: 15° - 30° » ≫ weight: 16,3kg Konformitätserklärung source four

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business
Filters

Results for

Heating radiators - Import export

Number of results

6 Products

Category