• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • din rails

Results for

Din rails - Import export

FranceService Provider

France

Verified by Europages

Polyethylene PEUHMW (ultrahigh molecular weight polyethylene). Glide rails for roller chains as defined in DIN ISO 606. These support and guide the roller chains on the return side, thus extending useful life by significantly reducing wear on the roller chains. They reduce vibrations and noise in the chain drive. These glide rails have high abrasion and wear resistance. They are maintenancefree, acidproof and have high chemical resistance. The additional C profiles are used for fastening to the system substructure and they protect the glide rails from lateral forces and torsion. Assembly The glide rails are pushed into the C profiles fastened to the system. The glide rails must be mounted so that the material is allowed to expand. A property of thermoplastic materials is that they expand or contract more than metals when there are temperature variations.

Request for a quote

France

Verified by Europages

Single-phase primary switched-mode power supply in metal housing. Note: Closed version with screw fittings with contact protection. Overload protection due to current limit, auto recovery. Protected against short-circuit, overload and surges. Power on LED indicator. For DIN top hat rail mounting. Technical data: Rating: IP00 Protection class: I Standard: UL508, TUV EN60950-1, CE Connection: screw terminals with contact protection Fastening: installation on DIN rail TS-35/7.5 or 15

Request for a quote

France

Verified by Europages

A switch disconnector ensures the interruption of current (under load) and the isolation of the load from the electrical supply. It provides optimal protection to users during machine maintenance as it can be locked with a padlock, preventing accidental startup during maintenance. Standard range: For 3P or 3P+N supply Ith 32 to 160A Available versions: In IP65 enclosure In enclosure with integrated fuse holder In cabinet bottom version (DIN rail mounting) with shaft (optional front plate) In panel mounting version (optional front plate)

Request for a quote

France

Compact 22.5 mm format Six Class A EN 50205 power contacts Removable terminals Cycle before dangerous failure: B10d=100,000 at 5A Max. closing time for NO contact: < 15ms (rebounds included) Duration of rebounds for NO contact: < 4ms Max. closing time for NF contact: < 16ms (rebounds included) Duration of rebounds for NF contact: < 13ms Protection severing wires: yes (opening of NO contacts) Safety contacts: 4x NO 8A/250V / 2x NF 8A/250V Indicators: 2 LEDs Reset: automatic Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

22.5mm DIN rail enclosure with removable terminals Economy of cabling (8 outputs for 255 functions) No programming Life cycle: 20 years Max activation distance: up to 45 mm Contact: 8 x 200 m APNP for 8-bit format Detection encoding: 16 million Indicator: 8 LEDs indicating the pathways activated Reset: no Mounting: symmetrical DIN 35mm rail after DIN 50022 Mounting: IP 54 electrical enclosure Material: PA6 Electrical connection: Maximum 14 AWG (2.08 mm²) Temperature: -15 °C to +60 °C Marking: label + serial number for traceability Option: badge nail, screw, plate screw, key chain, card ... etc.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Compact 22.5 mm format Suitable for RDX8 or other sensor Removable terminals Cycle before dangerous failure: B10d = 2,000,000 at 2A Risk duration: 10 ms max Cable severing protection: yes (opening of safety lines) Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting. Safety contacts: 2 x NO 8A/250V + 2 x NF 8A/250V Diagnostics: 1x NO 400mA/60V max Indicators: 3 LEDs Reset: automatic Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -25°C to +70°C.

Request for a quote

France

Version for mechanical or touch buttons KOB101T Controls the position of the press Removable terminals Performance level with AWAX controller: PL = e Safety category: IIIC Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 60 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: automatic with simultaneity control at 400 ms Position control: high press position contact input Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: INERIS 0080.5486.520.04.12.0059

Request for a quote

France

Add 4 power safety lines at 8A/250V with a safety PLC or control box without loss of Safety Class Compact format 22.5 mm/removable terminals Level of performance: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 4x NO 8A/250V redundant / 1x NF redundant in series (test) and 8A/250V parallel (information) C4SX indicators: 2 LEDs C5SX indicators: 2 LEDs Reset: automatic Number of inputs: 1 (C4SX) and 2 (C5SX) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Safety management in a compact 22.5 mm format Mono or two-channel with wiring. "Low consumption" Inputs Removable terminals Performance level with AWAX controller: PL = d Safety category: 3 (two-channel) Safety Integrity Level: SIL 2 Time before dangerous failure: MTTFd = 240 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 2x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant + 1x NO static 400 mA Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Safety management with 85~265 VAC power Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Compact 45 mm format Two position key switch: free and captive Removable terminals Level of performance: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 4x NO 8A/250V redundant / 1x NF redundant in series (test) and 8A/250V parallel (information) Indicators: 2 LEDs Reset: automatic Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Atex and machine safety management in a compact 45 mm format Atex dual-channel insulation barrier and controller for built-in machinery safety Atex safety ATEX standards EN 60079-0 EN 60079-11 EN 60079-25 EN 60079-26 ATEX marking [Ex ia] IIC Ga [Ex ia] IIIC Da II(1)GD Product used in combination with the "ANATOM78S- (PL or OX)-EEX" sensor Machine Safety Performance level with AWAX controller: PL = e in accordance with ISO 13849-1 Safety category: 4 in accordance with ISO 13849-1 Time before dangerous failure: MTTFd = 120 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting. Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant parallel Indicators: 3 LEDs Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +40°C. Certification: INERIS 06ATEX0007X

Request for a quote

France

Safety management on 9 outputs in a compact 45mm housing Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 75 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant in serial (XXL version) or parallel (XXLP version) Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management in 2 zones in a compact 45 mm format Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics zone 1: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Safety contacts/diagnostics zone 2: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Indicators: 2 display LEDs per zone for diagnostics and 1 LED for power Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Door unlocking control on motor shutdown Detection of asynchronous motors stoppage without external sensor Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Time before dangerous failure: MTTFd = 100 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: approx. 2 to 7s adjustable at front Persistence: approx. 20 mV to 700 mV adjustable front Motor power: up to 3x690 VAC Protection for severed wires: yes Protection against disconnection of motor coiling: yes Safety contacts: 3x NO 8A/250V redundant Diagnostics: 1x NF 8A/250V redundant parallel. 1 PNP "OK" output indicating motor coiling presence. 1 PNP "ERROR" output indicating a synchronization malfunction. 1 "RS" system reset input. Indicators: 3 LEDs for diagnostics Reset: automatic Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote