• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • sensor control

Results for

Sensor control - Import export

FranceManufacturer/producer

France

Verified by Europages

Submersible degreasing aerator The AEROSPEED is a submersible degreasing aerator that produces microbubbles which in turn causes grease to float onto the liquid surface. The unit is easy and simple to operate and install. Robust IP68 cast iron motor, coated with epoxy and equipped with a temperature control sensor Motor specially adapted to the constraints of operating a submerged degreasing aerator according to Europelec standards Stainless steel suction tube Stainless steel frame specially designed to optimize the hydraulic flow Stainless steel propeller specifically designed to ensure simultaneous mixing and suction of air.

Request for a quote

France

Verified by Europages

Controller based filter dust leak monitor (0100%) for filter emissions monitoring after bag houses, cartridge filters, cyclones etc. where performance approvals are not required. • reliable monitoring of leaking and broken bags in dust collectors • sensor configured remotely via controller • manual sensor drift checks • probe check option for improved data integrity • reduces filter maintenance intervals, process downtime and filter costs

Request for a quote

France

Verified by Europages

Multisensor dust monitor certified to category 1 under ATEX / IECEx designed for indicative emissions trending and measurement in challenging hazardous zones. Advanced probe electrification technology, perfectly adapted for particulate monitoring after bag filters, cartridge filters, cyclones and process driers, where regulatory approvals are not necessary. • reliable measurement of leaking and broken bags in dust collectors • sensor configured remotely via controller • automatic sensor drift checks • automatic probe check for improved data integrity • reduces filter maintenance intervals, process downtime and filter costs

Request for a quote

France

Verified by Europages

Certified multisensor dust monitor – category 1 under ATEX / IECEx – for indicative emissions trending and measurement in hazardous zones and in dry processes with elevated pressures. Advanced probe electrification featuring long term data logging for process trend analysis and reporting. • reliable measurement of leaking and broken bags in dust collectors • sensor configured remotely via controller • automatic sensor drift checks • automatic probe check for improved data integrity • reduces filter maintenance intervals, process downtimes and filter costs

Request for a quote

France

Verified by Europages

Controller based filter dust leak monitor (0100%) for filter emissions monitoring after bag houses, cartridge filters, cyclones etc. • reliable monitoring of leaking and broken bags in dust collectors • sensor configured remotely via controller • manual sensor drift checks probe check option for improved data integrity reduces filter maintenance intervals, process downtimes and filter costs

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Verified by Europages

Multisensor dust monitor for indicative emissions trending in industrial stacks after bag filters, cartridge filters, cyclones and process driers, where regulatory approvals are not necessary. Advanced probe electrification featuring long term data logging for process trend analysis and reporting. • reliable monitoring of leaking an broken bags in dust collectors • sensor configured remotely via controller • large graphic and numeric display • reduces filter maintenance intervals, process downtimes and filter costs

Request for a quote

France

Verified by Europages

RM2M offers a range of level sensors for liquids and solids. Rotary level sensors for solids: For high temperature, food processing, corrosive, or ATEX environments. Capacitive level sensors for solids: With power supply of 115-230VAC, 24-48VAC, or 24VDC. Membrane level sensors for solids: Operate with the pressure of the material on the membrane. Doesn't require a power supply. Pendular level sensors for solids: Simple and reliable sensor for powders forming a cone in the silo. Does not require a power supply. Conductive level sensors for liquids: Level sensor capable of controlling up to two levels. Available with the following power supplies: 115-230VAC, 24-48VAC, 24VDC. Floating level sensors for liquids: These models do not require an electrical power supply. Versions for agressive environments and food processing.

Request for a quote

France

Safety management with 85~265 VAC power Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Safety management in 2 zones in a compact 45 mm format Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics zone 1: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Safety contacts/diagnostics zone 2: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Indicators: 2 display LEDs per zone for diagnostics and 1 LED for power Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management on 9 outputs in a compact 45mm housing Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 75 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant in serial (XXL version) or parallel (XXLP version) Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Atex and machine safety management in a compact 45 mm format Atex dual-channel insulation barrier and controller for built-in machinery safety Atex safety ATEX standards EN 60079-0 EN 60079-11 EN 60079-25 EN 60079-26 ATEX marking [Ex ia] IIC Ga [Ex ia] IIIC Da II(1)GD Product used in combination with the "ANATOM78S- (PL or OX)-EEX" sensor Machine Safety Performance level with AWAX controller: PL = e in accordance with ISO 13849-1 Safety category: 4 in accordance with ISO 13849-1 Time before dangerous failure: MTTFd = 120 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting. Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant parallel Indicators: 3 LEDs Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +40°C. Certification: INERIS 06ATEX0007X

Request for a quote