• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • emergency stop

Results for

Emergency stop - Import export

France

France

Verified by Europages

Suitable for emergency stop and continual use. Energy reduction: 25% to 45%. Dynamic force absorption: 218 N to 3730 N Impact velocity: max. 5 m/s. The profile dampers are maintenance-free and are supplied ready to install with a special fastening screw. Environment: Resistant to microbes, sea water, chemicals and with very good UV and ozone resistance. No water absorption or maceration. Application: Linear slides and linear guides, pneumatic cylinders, furniture industry, machines and plants.

Request for a quote

France

Verified by Europages

Suitable for emergency stop and continuous use Energy reduction: 58% to 73% Dynamic force absorption: 870 N to 35190 N Impact velocity: max. 5 m/s. The profile dampers are maintenance-free and are supplied ready to install with a special fastening screw. Environment: Resistant to microbes, sea water, chemicals and with very good UV and ozone resistance. No water absorption or maceration. Fastening screws: Special cap screws with hex sockets, material 44SMn28 (free-cutting steel SAE 1144) electro zinc-plated: M6x9, M6x10, M8x14, M12x18, M16x26 ISO 4762 cap screws with hex sockets - 8.8 steel, black: M3x6, M4x8**, M5x10** ** With DIN 125 washer, electro zinc-plated steel. Application: Linear slides and linear guides, pneumatic cylinders, handling equipment, machines and plants

Request for a quote

France

Verified by Europages

TOUCH SCREEN Just press the touch screen and the LW2 takes care of the rest! The door closes automatically, the laser is positioned at the right focus height, the marking is done in a few seconds and the door opens. This laser station does not require training. Just prepare your marking jobs and load them into your industrial marking solution via the USB port. COMPLETE SAFETY This laser marking system is certified as class 1 laser products, allowing use in unrestricted environments: integrated fail-safe relay, protective glass, door closure security, emergency stop, door fitted with sensors and anti-pinch system, integrated extraction and filtration solution to protect users from dust and smoke. Mechanic and electronics are fully protected in a sealed box. Integrated alarms and controls. FLEXIBILITY Large marking area with 3 sided door, marking of a wide variety of parts, from small to big parts, from simple to complex shapes. The LW2 is compatible with most of our laser sources.

Request for a quote

France

Verified by Europages

The pendant push-button boxes of the RBAB range are the result of extensive ergonomics studies. They are extremely resistant to shocks that may occur in the industrial, logistics, or construction sectors. RM2M offers these push-button boxes with 2 to 12 control elements including: single speed button, double speed button, emergency stop (optional 2 NC contacts), 2 or 3 position fixed selector, key selector 2 or 3 fixed positions. Electrical contact life of 3 million cycles. Stock versions for control of hoists, hoist trolleys, and overhead cranes.

Request for a quote

France

Verified by Europages

All-terrain mobility: robust design, telescopic handle, pneumatic wheels, IP 65, IK 08 Control interface: on/off button, digital display with remaining operating time, emergency stop button Dimensions: H 625 x W 500 x L 297 mm Weight: 40 to 46 kg depending on model Equipment designed and manufactured in France, CE certified 2-year manufacturer's warranty

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Safety management in 2 zones in a compact 45 mm format Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics zone 1: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Safety contacts/diagnostics zone 2: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Indicators: 2 display LEDs per zone for diagnostics and 1 LED for power Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management on 9 outputs in a compact 45mm housing Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 75 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant in serial (XXL version) or parallel (XXLP version) Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

France

Safety management with 85~265 VAC power Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

The POUGET VT.3 Vibrating Tamping Set is supplied with : 1 Generating Set (petrol or diesel) three phase 220/380 V-50 Hz with an automatic safety brake, mounted on 2 rubber wheels. Fuel Motor Power (KVA) Weight (Kg) Essence HONDA LOMBARDINI 6 7 100 106 Diesel HATZ LOMBARDINI 6 112 4 Portable Vibrating Tampers at individual drive with automatic safety brake switch, and 10 meters insulated protective cable. . - Multiple vibrating directions - Unit power = 0,77 KW - Vibrations/min. : 50 Hz - Vibrating strength of tamping-blade : 660 Kg - Hardeness of tips = 63/68 Rockwell C - Unit weight of each tamper : 32 Kg The Portable Vibrating Tamping Machine is equipped with an operating adjustable handle in height and one safety brake switch. 1 Distributor Panel with : - 1 cable reel comprising 50 m. - 1 emergency stop button - 4 security connection - 1 general brake - weight = 32 Kg Noise level for the Workmen in operation : 90 dB (A) Vibrating level on Workmen handles : 5 m/s² IMPORTANT :

Request for a quote

France

Wireless emergency stop 4 function buttons + start/stop Light-weight, compact and ergonomic transmitters IP65 tightness, protective foams Integrated rechargeable battery Transmitter support charger Wireless emergency stop with safety PL e EN13849 and SIL 3 EN61508 6 static outputs + 2 safety relays 64 frequencies in 433MHz Infrared start-up option

France

Wireless safety logic signal transmission system Wireless safety logic signal transmission system Transmitters with 10 logical inputs + 1 emergency stop input Receivers with 6 static outputs + 3 safety outputs + 1 wired emergency stop input + 1 EDM input (monitoring of main contactors) Emergency stop category PL e EN13849 and SIL 3 EN61508 Housings with mounting on DIN rail 64 radio frequencies on 433MHz with standard range 25 radio frequencies on 433MHz with extended range Option : Infrared start-up validation