FlowJam T is a sensor for monitoring the flow of solids that are conveyed through thin pipelines. The sensor can be used for tubes made of electrically nonconductive material, such as plastic or rubber, with outside diameters between 4 and 25 mm. • mounted around the tube • triboelectric measurement • free crosssection • easy retrofitting

Request for a quote

France

Verified by Europages

Our load elevators, also known as material lifters (manual, electrical, pneumatic, hydraulic), will allow you to lift various loads (blinds, external air conditioning units, pergolas, engine blocks, etc.). Our manual range is available with the following specifications: -WLL 85kg, Height: 1.7-3.3m -WLL 100kg, Height: 1.65-4m -WLL 125kg, Height: 1.35-3.5m -WLL 125kg, Height: 1.45-4.56m -WLL 125kg, Height: 1.32-3.94m -WLL 150kg, Height: 1.53-4.5m -WLL 250kg, Height: 1.75-5.2m -WLL 280kg, Height: 1.75-5.2m Made in the EU Our electric range is available with the following specifications: -WLL 120kg, Max Height: 3.57m -WLL 90kg, Max Height: 4.87m Our pneumatic range is available with the following specifications: -WLL 136kg, Max Height: 3.8m -WLL 113kg, Max Height: 5.6m Our hydraulic range is available with the following specifications: -WLL 1500 kg, Height: 1-2.02m Made in France

Request for a quote

France

22.5mm DIN rail enclosure with removable terminals Economy of cabling (8 outputs for 255 functions) No programming Life cycle: 20 years Max activation distance: up to 45 mm Contact: 8 x 200 m APNP for 8-bit format Detection encoding: 16 million Indicator: 8 LEDs indicating the pathways activated Reset: no Mounting: symmetrical DIN 35mm rail after DIN 50022 Mounting: IP 54 electrical enclosure Material: PA6 Electrical connection: Maximum 14 AWG (2.08 mm²) Temperature: -15 °C to +60 °C Marking: label + serial number for traceability Option: badge nail, screw, plate screw, key chain, card ... etc.

Request for a quote

France

RFID sensor with 16 million codes Category 3 total security management without an external controller Programmable code through auto-learning (no software or PC) Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 (EN 954-1) Cycle after dangerous failure: B10d = 2000000 at 2 Amps Max activation distance: up to 24 mm Security contact/diagnostics: 2 x redundant NO 2A/48V and 1 x 400mA PNP auxiliary Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) or 50cm PUR cable with M12 connector (base + MKT) Sealing: IP 67 Temperature: -20 °C to +60 °C Marking: pad printing + serial number for traceability

Request for a quote

France

RFID sensor with 16 million codes Suitable for metallic environments Programmable code through auto-learning (no software or PC) Level of performance with AWAX controller: up to PL = e Safety category: up to 4 (EN 954-1) with AWAX controller Time to dangerous failure: MTTFd = 40 years Max activation distance: up to 24 mm Security contact/diagnostics: 2 x redundant NO 50mA/30V and 1 x 50mA auxiliary PNP Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 50cm PUR cable with M12 connector Sealing: IP 67 Standing room temperature: -30 °C to +50 °C. Storage temperature: -40 °C to +85 °C Marking: pad printing + serial number for traceability Certificate: E2 10R-04 14053 (UTAC) ISO 7637-2 (Pulse 1, 2a, 2b, 3a, 3b, 4)

Request for a quote

France

RFID sensor with 16 million codes Lock control and two alarm levels Programmable code through auto-learning (no software or PC) Switching cycle: B10 = 1 million Max activation distance: up to 25 mm Contact/diagnostics: 1 x 1.8A PNP timed 5s/2 x 200m APNP Alarm 1 (120s failure to close) and 2 (30s breaking open) Duration of alarms editable upon request (XR530P, P1 ... P10) Detection encoding: 16 million Indicator: LED indicates code recognition Optional erasing card to reassign new codes Encoding of geographic location: (base + E1 to E10) Reset : automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m (UL2464 PVC) Sealing: IP 67 Temperature: -25 °C to +70 °C. Marking: pad printing + serial number for traceability Option: badge nail, screw, plate screw, key chain, card ... etc. Application example: access to luxury showcases with lock control

Request for a quote

France

RFID sensor with 16 million codes Lock control and "burglar" alarm Supervision, traceability via PC, RS485 network and output contacts Life cycle: 20 years Max activation distance: up to 45 mm Contact/diagnostics: 1 x 1.8A PNP timed 5s/2 x 100mA PNP Alarm 1 (120s failure to close) and 2 (30s breaking open) Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 1 Material: POLYCARBONATE Electrical Connection: 50cm PUR cable with M12 connector Sealing: IP 67 Temperature: -20 °C to +60 °C Marking: pad printing + serial number for traceability Options: - Software for real-time monitoring with openings traceability via PC (ref MDB13-SP.) - Software programming of badges and network configuration (ref MDB13-PR.) - Automatic network connection (LKS485): up to 8 cascading boxes and 4 readers per box or 32 readers. Individual contact outputs on each box - badge nail, screw, plate screw, key chain, card ... etc. Application example: access to luxury showcases with lock control and traceability

Request for a quote

France

Ultra-compact format Automatic RS485 networking with M12 connector output Deferral of all M12 connector outputs Indicator: LED indicates activation of the network Attachment: 4 M3 screws (with washers) Mounting position: 1 Material: POLYCARBONATE Electrical connection: 8 M12 connectors Sealing: IP 54 Temperature: -20 °C to +60 °C Marking: pad printing + serial number for traceability Options: - Software for real-time monitoring with openings traceability via PC (ref MDB13-SP.) - Software programming of badges and network configuration (ref MDB13-PR.) - Automatic network connection (LKS485): up to 8 cascading boxes and 4 readers per box or 32 readers. Individual contact outputs on each box - badge nail, screw, plate screw, key chain, card ... etc. Application example: access to luxury showcases with lock control and traceability

Request for a quote

France

Ultra-compact, very thin, plugs directly into the PLC Process management, sorting ... etc. MODBUS RS485 (RTU) or RS232 (ASCII) network Life cycle: 20 years Max activation distance: up to 45 mm Contact: 1 x strobe PNP /1 RS485 (base + 485) or RS232 (base + 232) Detection encoding: infinite Indicator: LED indicates code recognition Reset: automatic Mounting: M30 nut provided Mounting position: 1 Material: TR90UV Electrical connection: screwless terminal Sealing: IP 67 Temperature: -20 °C to +60 °C Marking: screen printing Options: - Stainless steel badge holder: AXKEF/CARD HOLDER - badge nail, screw, plate screw, key chain, card ... etc.

Request for a quote

France

22.5mm DIN rail enclosure with removable terminals No software or PC configuration 8 combinable outputs Life cycle: 20 years Max activation distance: up to 45 mm Contact: 8 x 200 mA PNP for 8-bit format Detection encoding: 16 million Indicator: 8 LEDs indicating the pathways activated Action: Momentary (ref + M), bistable (ref + B), timed (ref + MKT) Mounting: symmetrical DIN 35mm rail after DIN 50022 Mounting: IP 54 electrical enclosure Material: PA6 Electrical connection: Maximum 14 AWG (2.08 mm²) Sealing: IP 67 Temperature: -15 °C to +60 °C Marking: label + serial number for traceability Option: badge nail, screw, plate screw, key chain, card ... etc.

Request for a quote

France

Machine status signaling 4 types of selectable indications Low apparent thickness • Service life: 50,000 hours • Luminosity: 100 lm • Mode 1: flash • Mode 2: Flashing • Mode 3: Fixed • Mode 4: Revolving • Trim color: black, white, yellow, red • Attachment: 51mm bore and 2 to 6 D3 invisible screws (not included) • 8mm low visible thickness • Mounting position: 1 • Material TR90UV • Electrical connection: 1m 7 x 0.25mm² cable (other lengths on request) • Water resistance: IP 67 with peripheral silicone seal • Temperature: -5°C to +40°C. • Printing: screen printing for the reference on the back of the product

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Cylindrical M18 for "invisible" assembly Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 6 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.8A max/24V redundant / 1xcontact PNP 250mA Detection encoding: mono-code inviolable Reset: automatic Attachment: 2 M30 nuts provided Mounting position: 1 Material: CuNi Electrical connection: M12 metal base Water resistance: IP 67 Temperature: -20°C to +60°C Marking: label + serial no. for traceability

Request for a quote

France

Dynamic detection of approaching hand even wearing gloves Fraud reduction system and MSD reduction Capacitive and optical technology touch button Performance level with COM3C controller: PL = e Safety category with COM3C: IIIC (EN 574), 4 (ISO 13849-1) 'Failsafe' level with COM3C: SIL 3 Time before dangerous failure: MTTFd = 100 years Activation distance: on touch (0 force = MSD reduction) Safety contacts: 1 x PNP NO/50mA OSSD and 1 x PNP NF/50mA OSSD Diagnostics: fraud, simultaneity, short-circuiting of contacts with multi-function illuminated ring Reset: automatic with two buttons correctly activated Attachment: Attachment: 51mm bore and 2 to 6 invisible D3 screws (not included) Mounting position: 1 Material: TR90UV yellow Electrical connection: 6-way screwless push terminal 1.5mm² Water resistance: IP 67 with silicone seal on the trim Temperature: -25°C to +60°C Marking: screen printed + serial no. for traceability Recommendations: use gloves in accordance with EN 388

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Suitable for groove profiles and single or double doors Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 8 mm, 3 mm hysteresis Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 1 x PNP 250mA (X5) or 1xNF (X5.2) auxiliary Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic (SR version) or Manual (AR version) Attachment: 4 tamper-proof M4 screws (optional ref: BH4). Suitable for grooved profiles. Screw caps provided. Mounting position: 1 Material: Polycarbonate Electrical connection: 1 M12 connector (X5 version) or 2 M12 connectors (X5.2 version for instant serial connection) Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: screen printed + serial no. for traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 50mA Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts: 2 x NO 250 mA/48V redundant Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) Water resistance: IP 67/68 Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 100mA Max. activation distance: 6 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 1A/48V redundant / 1 x PNP 1A auxiliary Detection encoding: mono-code inviolable Indication: LED indicating code absence Reset: automatic Attachment: 2 M30 nuts provided Mounting position: 1 Material: CuNi Electrical connection: 3, 6, 12m cable Water resistance: IP 67 Temperature: -25°C to +60°C Marking: label + serial no. for traceability

Request for a quote

France

Redundant low and high pressure control with channel synchronization Pressure control from 0.1b to 300b (to be defined when ordering) Vacuum control from -0.2b to -0.9b (to be defined when ordering) • Level of performance with AWAX controller: up to PL = e • Level of performance only: PL = c • Safety category with an external controller: up to 4 • 'Integrated security' level with an external controller: up to SIL 3 • Cycle before dangerous failure: B10d = 100,000 • Safety contacts: 2 x NO 2A/50V • Auxiliary contact: 1 x PNP NF 2A/50V • Reset: automatic • Attachment: 4 x M4 flat head or domed screws • Mounting position: 1 • Material: Polycarbonate • Electrical connection: PUR UL20549 very durable 50 cm cord with M12 connector • Pneumatic connection: G1/4 and 8 mm quick connector • Water resistance: IP 65 • Ambient temperature: -25°C to +60°C • Fluid temperature: -40°C to 140°C (specify temperature and the nature of the fluid in the order) • Marking: label + serial no. for traceability

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Manages person entry in hazard zones using an electrical locking key Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Electrical locking key with position contact Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 2xPNP 250mA auxiliary (open/closed door and locking/unlocking of contacts) Detection encoding: mono-code inviolable Note: two-color LED indicates the key locking position; white LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: Polycarbonate Electrical connection: M12 metal base Water resistance: IP 65 Temperature: -15°C to +60°C Marking: screen printed + serial no. for traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Suitable for groove profiles and single or double doors Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 334 years Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.8A max/24V redundant / 1xNF (78S) or 1 x NO (98S) 250mA Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4). Suitable for grooved profiles. Screw caps provided. Mounting position: 1 Material: Polycarbonate Electrical connection: 2 M12 metal bases for instant serial connection Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: screen printed + serial no. for traceability

Request for a quote