The ideal storage temperature is around 23°C with the humidity over 50%. 2. Do not open the bag before use. Please try to finish the whole package of cable ties shortly once it's opened. Do seal the bag if there will be the remaining pieces in the bag without using at once. 3. Do not expose directly under sunlight except UV weather resistant cable ties. 4. Avoid storing cable ties next to warm objects like heaters.

Request for a quote

France

Verified by Europages

Axon’ offers extruded flat cables with round conductors for any application requiring space reduction and temperature resistance. The round conductors are insulated with FEP or ETFE. These ribbon cables are characterized with their temperature resistance : -90°C to + 155°C for ETFE, -90°C to +155°C for ETFE insulated flat cables. They are highly resistant to abrasion and traction and have an excellent flexlife.They are available in 1.27 mm and 2.54 mm pitches.

Request for a quote

France

Verified by Europages

Axomove® is a range of round composite cables specially designed for robotic technology applications. They are able to meet the most demanding requirements of the automation technology. The main characteristics are as follows : good flexlife and resistance to torsion, small dimensions, small bend radius, resistance to oil and solvents, abrasion resistance, EMI protection. Depending on customer requirements, they can be composed of round or flat primary wires or both Insulation : FEP, PTFE, ETFE, PFA, polyimide, vitax™ , PU, ... Shielding for EMI protection when required

Request for a quote

France

Verified by Europages

Vibraflame® is a range of cables designed to resist extreme temperatures ranging from -196°C to +1565°C.These fire resistant range of cables do not propagate flame and do not contain asbestos. They can be used as control, coaxial or power feed cables. Axon’ offer extension and compensating cables for thermocouples insulated with vibraflame® material and resistant to temperatures of up to 1050°C. These heat resistant cables can be made with nickel plated copper, nickel alloy, nickel chrome, iron, constantan, copper alloy, cupronickel for extension and compensating cable. They are insulated with a special combination of mica, organic polymers and fibre glass. Applications include power and control cables in steel works, oil refinery, electric furnace, blast furnace,etc

Request for a quote

France

Verified by Europages

Axon' offers an extended range of equipment wires and cables for any applications requiring resistance to high temperatures. Different types of constructions can be proposed and delivered ex stock. They are designed to resist high temperatures ranging from -90°C to +260°C depending on the insulation material ; PTFE, ETFE, FEP or polyimide. They are made with silver plated or nickel plated conductor copper alloy, tin, silver or nickel plated copper. They can be used for various applications: aeronautics, automotive, space telecommunications, electronics, military equipment, general industry, ...

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 100mA Max. activation distance: 6 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 1A/48V redundant / 1 x PNP 1A auxiliary Detection encoding: mono-code inviolable Indication: LED indicating code absence Reset: automatic Attachment: 2 M30 nuts provided Mounting position: 1 Material: CuNi Electrical connection: 3, 6, 12m cable Water resistance: IP 67 Temperature: -25°C to +60°C Marking: label + serial no. for traceability

Request for a quote

France

Sensor contactless technology, low simultaneity ATEX Zone 2 and 22 category 3GD No power Atex safety EN 60079-15 EN 61241-1 Machine Safety Level of performance with AWAX26XXL-EEX3 controller: up to PL = e in accordance with EN ISO 13849-1 Cycle before dangerous failure: B10d = 62,500 Max. activation distance: 17 mm, 5 mm hysteresis Safety contacts/diagnostics: NO 2 x 50 mA/24V redundant 1xNF/50mA/24V redundant parallel Overcurrent: 500mA for 2s Shock resistance: 50 G. Vibrations: 30 G Detection encoding: mono-code Indicators: no Reset: automatic Total number of connectable sensors in series: 30 Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Marking: pad printing + serial no. for traceability Electrical connection: 3, 6, 12m cable Water resistance: IP 67 Temperature: -5°C to +80°C.

Request for a quote

France

Contactless "door lock" encoded detection Contactless "door open / closed" detection Unlock command with just one contact during serialization of products Emergency evacuation handle • Level of performance with AWAX controller: up to PL = e Safety category with an external controller: up to 4 • Cycle before dangerous failure: B10d = 1,000,000 • Bolt travel: 14 mm • Bolt diameter: 24 mm (beveled for "under-voltage" closed position or "lock" mode) • Shearing strength: 2000 N • Gap between strike and lock: 2 to 4 mm (adjustable when assembling, recommended to 4 mm) Maximum lateral offset between strike and lock: +/- 2.5 mm • Maximum angular displacement between strike and lock: +/- 5° • Safety locking contacts: 2 x NO 2A/50V • Safety door contacts: 2 x PNP/500 mA • Unlock command: PLC-compatible (12~30 VDC/2~5 mA) • Fault Diagnosis: bolt stuck, power out of specification, temperature out of specification, electromagnet failure, serialization failure • Reset: on command • "SMART consumption" for minimal power consumption when connected in series • Auxiliary release: female triangle key 8 mm x 14.2 mm (optional) • Attachment: 4 M6 screws (screw covers supplied, screws not included) • Mounting position: 2 (door pulling, door pushing) • Material: PA6 fiberglass reinforced • Electrical connection: very resistant 50 cm PUR UL20549 cord with M23 connector or cable (contact us) • Water resistance: IP 65 • Operating temperature: -15°C to +45°C • Marking: screen printed + serial no. for traceability • Reference for evacuation handle: AT

Request for a quote

France

Contactless "door lock" encoded detection Unlock command with just one contact during serialization of products • Cycle before dangerous failure: B10d = 1,000,000 at 200mA • Bolt travel: 9 mm • Bolt diameter: 12 mm • Shearing strength: 1000 N • Distance between latch and lock: 0 to 4 mm (adjustable when assembling, recommended to 4 mm) • Maximum lateral displacement between strike and lock: +/- 0.8 mm • Maximum angular displacement between strike and lock: +/- 5° • Safety locking contacts: 2 x NO 0.4A /24V redundant and • Unlock command: PLC-compatible (12~30 VDC/2~5 mA) • Diagnostic error: Auxiliary output indicates unlocking • Reset: on command • Infinite automatic offset control when connected in series: minimal consumption • Auxiliary release: key supplied (free key in lock mode; captive key in release mode) • Attachment: 4 M4 screws (screw covers included) • Mounting position: 1 • Material: PA6 fiberglass reinforced • Electrical connection: very resistant 50 cm or 130 cm PUR UL20549 cord with M12 connector or cable (contact us) • Water resistance: IP 65 • Ambient temperature: -5°C to +40°C. • Marking: screen printed + serial no. for traceability

Request for a quote

France

40N integrated stainless steel magnetic door holding Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 4 mm, 2 mm hysteresis Holding Force: transmitter + receiver in contact = 40N Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 1 x PNP 250mA encoding detection: single inviolable code Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 1 Material: INOX 316L mirror polished Electrical connection: 3, 6, 12m cable Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: INOX316L laser engraving with mechanical punching of the serial number for permanent traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 50mA Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts: 2 x NO 250 mA/48V redundant Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) Water resistance: IP 67/68 Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability