Sensor contactless technology, low simultaneity ATEX Zone 2 and 22 category 3GD No power Atex safety EN 60079-15 EN 61241-1 Machine Safety Level of performance with AWAX26XXL-EEX3 controller: up to PL = e in accordance with EN ISO 13849-1 Cycle before dangerous failure: B10d = 62,500 Max. activation distance: 17 mm, 5 mm hysteresis Safety contacts/diagnostics: NO 2 x 50 mA/24V redundant 1xNF/50mA/24V redundant parallel Overcurrent: 500mA for 2s Shock resistance: 50 G. Vibrations: 30 G Detection encoding: mono-code Indicators: no Reset: automatic Total number of connectable sensors in series: 30 Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Marking: pad printing + serial no. for traceability Electrical connection: 3, 6, 12m cable Water resistance: IP 67 Temperature: -5°C to +80°C.

Request for a quote

France

RFID sensor with 16 million codes Category 3 total security management without an external controller Programmable code through auto-learning (no software or PC) Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 (EN 954-1) Cycle after dangerous failure: B10d = 2000000 at 2 Amps Max activation distance: up to 24 mm Security contact/diagnostics: 2 x redundant NO 2A/48V and 1 x 400mA PNP auxiliary Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) or 50cm PUR cable with M12 connector (base + MKT) Sealing: IP 67 Temperature: -20 °C to +60 °C Marking: pad printing + serial number for traceability

Request for a quote

France

RFID sensor with 16 million codes Suitable for metallic environments Programmable code through auto-learning (no software or PC) Level of performance with AWAX controller: up to PL = e Safety category: up to 4 (EN 954-1) with AWAX controller Time to dangerous failure: MTTFd = 40 years Max activation distance: up to 24 mm Security contact/diagnostics: 2 x redundant NO 50mA/30V and 1 x 50mA auxiliary PNP Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 50cm PUR cable with M12 connector Sealing: IP 67 Standing room temperature: -30 °C to +50 °C. Storage temperature: -40 °C to +85 °C Marking: pad printing + serial number for traceability Certificate: E2 10R-04 14053 (UTAC) ISO 7637-2 (Pulse 1, 2a, 2b, 3a, 3b, 4)

Request for a quote

France

RFID sensor with 16 million codes Suitable for metallic environments Programmable code through auto-learning (no software or PC) Max activation distance: up to 24 mm Security contact/diagnostics: 2 x 400mA and 1 x 200mA auxiliary PNP Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 50cm PUR cable with M12 connector Sealing: IP 67 Standing room temperature: -25 °C to +70 °C. Storage temperature: -40 °C to +85 °C Marking: pad printing + serial number for traceability

Request for a quote

France

RFID sensor with 16 million codes Lock control and two alarm levels Programmable code through auto-learning (no software or PC) Switching cycle: B10 = 1 million Max activation distance: up to 25 mm Contact/diagnostics: 1 x 1.8A PNP timed 5s/2 x 200m APNP Alarm 1 (120s failure to close) and 2 (30s breaking open) Duration of alarms editable upon request (XR530P, P1 ... P10) Detection encoding: 16 million Indicator: LED indicates code recognition Optional erasing card to reassign new codes Encoding of geographic location: (base + E1 to E10) Reset : automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m (UL2464 PVC) Sealing: IP 67 Temperature: -25 °C to +70 °C. Marking: pad printing + serial number for traceability Option: badge nail, screw, plate screw, key chain, card ... etc. Application example: access to luxury showcases with lock control

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Ultra-compact format Automatic RS485 networking with M12 connector output Deferral of all M12 connector outputs Indicator: LED indicates activation of the network Attachment: 4 M3 screws (with washers) Mounting position: 1 Material: POLYCARBONATE Electrical connection: 8 M12 connectors Sealing: IP 54 Temperature: -20 °C to +60 °C Marking: pad printing + serial number for traceability Options: - Software for real-time monitoring with openings traceability via PC (ref MDB13-SP.) - Software programming of badges and network configuration (ref MDB13-PR.) - Automatic network connection (LKS485): up to 8 cascading boxes and 4 readers per box or 32 readers. Individual contact outputs on each box - badge nail, screw, plate screw, key chain, card ... etc. Application example: access to luxury showcases with lock control and traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Low cost solution for multi-access applications Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 420 years Max. activation distance: 9 mm, 1 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.4A max / 24V redundant and 1 x 250mA PNP contact Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 or INOX 316L mirror polished (ref. + OX) Electrical Connection: 3, 6, 12m cable (UL2464 PVC) or 50cm cord with M12 connector (UL20549 PUR) (ref. + MKT) Water resistance: IP 67/68 or IP 69K stainless steel version (requires cable input protection) Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Low cost solution for multi-access applications • Level of performance with AWAX controller: up to PL = e • Safety category: up to 4 with an AWAX controller • Time before dangerous failure: MTTFd = 334 years • Max. activation distance: 10 mm, 2 mm hysteresis • Safety contacts/diagnostics: 2 x NO 0.8A max / redundant 24V / 1xcontact PNP 250mA • Detection encoding: mono-code inviolable • Indicator: LED indicates code recognition • Reset: automatic • Attachment: 4 tamper-proof M4 screws (optional ref: BH4) • Mounting position: 78S-98S, 78SMKT, 78SMKT130 versions: 2 (double wall brackets) • Mounting position: 78SM12 and 98SM12 versions: 1 • Material: 78S-98S, 78SMKT, 78SMKT130: PA6 or INOX316L (ANATOM78S-OX or ANATOM78S-OX-MKT) • Matierial for 78SM12, 78SESM12 and 98SM12 : polycarbonate (PC) • Electrical Connection: 3, 6, 12m cable (78S/98S) or 50cm cord with M12 connector (ref. + MKT) or 130cm cord with M12 connector (ref. + MKT130) or M12 metal (ref. + M12) • Water resistance: IP 67/68 (PA6, PC) or IP 69K with stainless steel - new generation • Temperature: -25°C to +60°C • Marking: PA6 pad printing + serial no., PC pad printing + serial no., INOX316L laser engraving with mechanically punched serial no. for permanent traceability • Certification: UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209) (Not applicable for versions MKT and M12)

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 50mA Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts: 2 x NO 250 mA/48V redundant Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) Water resistance: IP 67/68 Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability

Request for a quote

France

Contactless encoded electronic sensor with relay Up to 8 zone differentiation codes Safety contacts 2A / 250V • Level of performance without an external controller: PL = c • Level of performance with AWAX controller: up to PL = e • Safety category without an external controller: 1 • Cycle before dangerous failure: B10d = 2,000,000 at 2A • Max. activation distance 3SSR24V/5SSR24BX/5SSR24BX-US: 8 mm, 2 mm hysteresis • Max. activation distance 2SSR24V/2SSR24BX: 4 mm, 2 mm hysteresis • Safety contacts/diagnostics 3SSR24V: 1 x NO 2A/250V / 1 x NF 2A/250V auxiliary • Security contacts/diagnostics 5SSR24BX and 5SSR24BX-US: 2 x NO 2A/250V / 1 x PNP NF 250mA auxiliary (24V) • Security contacts 2SSR24V: 2 x NO 2A/250V • Security contacts 2SSR24BX: 1 x NO 2A/250V and 1 x NF 2A/250V • Detection encoding 3SSR24V, 5SSR24BX/5SSR24BX-US: single inviolable code • Detection encoding 2SSR24V and 2SSR24BX: 8 inviolable codes • Indicators 2SSR24V, 2SSR24BX, 3SSR24V and 5SSR24BX: Red LED indicating code absence (not transmitter) • Indicator 5SSR24BX-US: Two-color red/green LED • Reset: automatic • Attachment: 4 tamper-proof M4 screws (optional ref: BH4) • Mounting position: 2 (double wall brackets) • Matierial PA6: 2SSR24V, 2SSR24BX, 3SSR24V, 5SSR24BX, 5SSR24BX-MKT and 5SSR24BX-US • Material INOX 316L mirror polished: 5SSR24BX-OX and 5SSR24BX-OX-MKT • Electrical Connection: 3, 6, 12m cable or 50cm cord with M12 connector (UL20549 PUR) for5SSR24BX-OX and 5SSR24BX-OX-MKT • Water resistance: IP 67/68 (PA6) or IP 69Kwith stainless steel - new generation • Temperature: -25°C to +60°C • Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle after dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 10 mm, 2 mm hysteresis Security contacts / diagnostics AMX5 / AMX5CM12: 2 x NO 2A / 48V redundant / 1 x PNP 250mA auxiliary Security contacts AMX4: 2 x NO 2A/48V redundant Security contacts / diagnostics AMX3: 1xNO 2A / 48V redundant (2 series contacts) / 1xNF 250mA auxiliary Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 or INOX 316L mirror polished (AMX3-OX/AMX5-OX ⇥or PC (AMX5CM12) Electrical Connection: 3, 6, 12m (UL2464 PVC) or 50cm cable with M12 connector (UL20549 PUR) (ref + MKT) or M12 metal base (AMX5CM12) Water resistance: IP 67/68 (PA6 / PC) or IP 69K with stainless steel - new generation Temperature: -25°C to +60°C Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12 UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209)

Request for a quote

France

250 VAC lighting switch in the premises 24 VDC machine control Request for stop/opening for public transport • Number of cycles: 100 million at 200 mA • Standard activation distance: 0 mm • Electrical contact KB100A: 1 RT 1700 VA/250V • Electrical contact KB100M: 1 NO, 1 NO+1NF, 8A/250V • Electrical contact KB100M: 1 PNP NO, 400mA/24V • Selectable features KB100A and KB100M: bistable, monostable, deferred stop (90s timer), delayed start (350ms). Other value on request. ▪ Function details: • ON/ON = momentary with fraud protection The action is canceled if the finger or organic material is present longer than 5s ON/OFF = bistable. One pulse switches the contacts and another pulse places the contacts at rest ON/duration/OFF = delayed stop 90s "timer" feature (other value on request) Offset ON = delayed start. To confirm the request the button must be held for 350ms (other values on request) ▪ Indication by LED ring offset effect: KB100A: white or amber color (other on request) KB100M: green and red color KB100TR: green and red color ◦ Bicolor LED indication by external control: version "OL" • Attachment 1: recessed box for plaster panel (2 D3 screws) • Attachment 2: panel by invisible screwing (2 to 6 D3 screws) • Material: TR90UV • Food contact: yes • Resistance to washing: yes • Anti-vandalism: yes • Electrical connection: 1m cable or 1.5mm² connector without screws • Water resistance: IP 67 with peripheral silicone seal • Temperature: -25°C to +60°C • Marking: pad printing on the trim of some models Silkscreen reference on the back of the product