Türkiye, Istanbul
...Acoustic Testing Cabins are specialized enclosures designed for conducting precise evaluations of soundproofing and acoustic performance. These cabins provide controlled environments for testing materials, components, and products under various noise conditions. Equipped with advanced sound measurement instruments and analysis tools, these cabins facilitate comprehensive acoustic testing. They...
Austria, Aurolzmünster
... measurement include: + Measurement of sound emissions from existing systems + Professional evaluation of the sound situation + Sound prediction calculations for new components + Soundproofing design for individual components and the overall system + CFD flow simulation for optimizing flow management + Specific sound measurements and environmental analysis + Volume flow measurements...
France, Muttersholtz
...Features: - Applications: Fixed or mobile environmental measurements: water, air, noise Request a quote at 03 67 60 00 52 MODULO PROTECT Shelter for analyzing water, air, and noise - fixed or mobile Features: - Applications: Fixed or mobile environmental measurements: water, air, noise Description Our analysis shelter allows you to perform various types of water, air, and noise measurements in...
Luxembourg, Ehlange Sur Mess
... - VOCs (volatile organic compounds) - temperature - low-frequency electromagnetic fields - high-frequency electromagnetic fields - noise pollution - Wi-Fi - water quality - chlorine / hardness / alkalinity - pH / nitrite and nitrate - air quality - H2 / LPG / alcohol - NH3 / ethanol / toluene Consult our professionals You will be able to communicate with us and create a quote together to find the best solution for your safety.
Germany, Otterfing
...In the waterfall, the classic FFT is extended along a time axis. The spectrum can be observed along this time axis. This representation highlights very small oscillation components against the background noise. In the two-dimensional representation, very small peaks can easily be overlooked, especially when they fade and reappear over time. The waterfall displays the spectrum of a tuning fork for 28 seconds after being struck. The graph clearly shows that the oscillations at 881 Hz and 1320 Hz disappear and reappear.
Türkiye, Izmir
... glazing. It eliminates the insulation disadvantage in sliding systems and makes the corners open. It distinguishes itself from other products with its comfortable movement thanks to its carrier wheels, which allow 1.5 meter panels and its own special lock system and patented. In SKYSLIDE, a Speed-HD wheel with a panel carrying capacity of 150 kg, with stainless bearings, adjustable height and suspension that adapts to the situation on the road is used. All flaps move, open and close comfortably, with minimal friction and noise.
United Kingdom, Milton Keynes
... best acoustic performances for composite inspection. The combination of RSflite and WheelProbe2 makes the fastest portable immersion inspection system on the market. The advanced UTmap analysis tools and unique C-Scan stitching capability increase overall productivity and enhance the inspection quality.
Belgium, Fernelmont
... Synchronization in the millisecond range for several hours POSSIBLE USE "Quick & dirty" vibration monitoring & diagnosis Remote diagnosis and consultation of vibrations Vibration measurement on rotating parts Vibration modal analysis Machine tools - Automotive - Aerospace Structural analysis and condition monitoring Traffic and transport sector BENEFITS Our new wireless vibration recorder RECOVIB Tiny measures vibrations and shocks in all three axes. It is extremely convenient for vibration diagnosis and offers up to 6 hours of measurement duration.
Germany, Wasserburg
... diameters of up to 250mm are possible. In our prototype department, we are able to simulate or modify the environmental circumstances of the fan wheels or turbines, thus achieving optimal operational conditions. Furthermore, we carry out mould-flow analysis, use ANSYS from external partners for the flow simulation and establish the fault probability and fault effect with FPFEs. New: Development of blower systems and optimization of ventilation systems.
Switzerland, Bulle
...The radial clearance is not considered a quality criterion. An improper radial or axial clearance may have detrimental implications during operation within an application. This may include suboptimal noise levels, heat generation, rigidity, and fatigue life. Prior to recommending an internal clearance range, our applications will run an analytical simulation on the bearing and application to ensure optimal performance. For more complex system, our application engineers can complete a FEA analysis, particularly when evaluating multiple bearings within a non-rigid housing.
Germany, Zeuthen
... output with signal generator (DC, 0-100kHz sine, sweep) •,Up to 100kHz bandwidth synchronously sampled across all channels •,16/24 bit resolution with 110+dB signal-to-noise ratio •,Compact dimensions (40 x 90 x 170 mm) •,Freely scalable! From one device with 4 analog channels to multiple devices with any number of channels •,1x Ethernet interfaces, connection for external 12V power supply, LVDS port for synchronization of multiple devices, USB port, IRIG input...
Germany, Köln
... designed to unlock your process with industry leading performance for all of your gas analysis applications to help maximize chip yields and minimize tool downtime. Combined with a low overall cost of ownership and high mean-time-between-failures, Transpector MPH helps your bottom line more than any other residual gas analyzer (RGA) on the market. INFICON has leveraged its expertise in gas analysis...
Germany, Berlin
... sound camera includes all components for acoustic measurements, data collection, and data analysis in one device. The acoustic images are displayed in high resolution and in real-time on the large screen of the Microsoft® Surface Tablet PC or, thanks to the ultra-fast USB-3 interface, on any device. The analysis software NoiseImage Mobile allows for easy and intuitive recording with pre-set layouts and in-depth detail analysis using powerful algorithms and filters.
Germany, Hallbergmoos
... install and use. Monitoring: Measurement and storage of primary data: noise, air quality, flight paths, weather, etc. Automatic identification of flight events Real-time or non-real-time visualization of flight paths and noise Analysis: Analysis of flight paths and detection of unusual situations Long-term statistical calculations Generation of informative reports Verification of compliance with legislation Communication: Provision of flight paths and noise data for residents etc. Country of origin: France...
Germany, Ettlingen
...The INVENIO offers outstanding spectroscopic performance, innovative new technologies, and intelligent design. It is perfectly customizable to your needs and supports you individually through smart workflows. Features: • Excellent signal-to-noise ratio • Wide spectral range (FIR, MIR, NIR, and VIS/UV) • Touch PC with specialized software for increased productivity • Time-resolved spectroscopy...
...ES offers in its range of sound analysis its low-noise audio analyzer. Innovative, high-performing, and reliable, Audio Precision distributes this model and opens the doors to a new era of audio analyzers: Features: - THD+N of -120 dB, the two analog channels of the APx555 are market leaders - Bandwidth of 1 MHz in mono - Resolution of 1.2 M points for FFT - Internal generator capable of...
...ETG 9500 is the most flexible and cost-effective solution for FTIR analysis. ETG Resources has developed a spectrometer using the best materials, achieving a high signal-to-noise ratio and long-lasting components. Its simple interface and practical features make it the number one ally in industrial monitoring. The ETG 9500 analyzes the entire Infrared Spectrum, and at the same time, adding new...
...and cost analysis •Acoustic assessment of entertainment venues (DPCM 16-04-1999 n.215) and temporary activities (musical events and construction sites) •WBV and HAV vibrations •Predictive vibrational analysis of machines...
France, Hoerdt Cedex
... levels are displayed on the screen, allowing for reliable and differentiated analysis. Lightweight, maneuverable, and compact – the receiver impresses with its size and maximum ease of use. Adjustable filters and an automatic frequency filter allow the operator to tailor the listening frequency ranges, reduce background noise, and optimize acoustic quality for reliable leak analysis.
...Allows for the acquisition and recording of temperature, humidity, light, noise, and vibration levels every second - 24 hours a day. It can also be permanently installed for long-term monitoring. Completely mobile, it enables measurements anywhere within the laboratory animal space.
...In the event of a power outage – a so-called blackout – that cannot be bridged by UPS and battery systems, emergency backup power systems come into play. We conduct needs assessments that establish the structural and electrical requirements for the installations. In doing so, we develop the integration of diesel engines and electric generators, the ventilation of the technology, the noise protection requirements, diesel or heating oil requirements, as well as requirements for trial operation under partial or full load and grid feedback.
Türkiye, Istanbul
...Please ensure that the individuals conducting Electrical Periodic Inspections within your company are not the designer, supplier, installer, seller, owner, user, maintainer, or authorized representative of the equipment being inspected, in terms of independence, impartiality, and reliability. Our services in this area include: - EMC Testing (Electromagnetic Compatibility) - LVD Testing (Low Voltage Directive) - Other Tests (Noise Testing and Acoustic Measurements, Sealing Test - IP Protection Test, Mechanical and Physical Tests, Fire Resistance and Reaction Tests)...
ufs.country_names.RU, Moscow
... sample will also help to examine the same surface region with different AFM modes, making the surface analysis more comprehensive. Temperature Recovery Time:< 20 minutes. Acoustic Protection:the averaged sound energy loss -30 dB for 300 Hz – 3 kHz bandwidth. Vibration Protection:the noise level is characterized by 0.09 nm probe deflection for the passive and active damping Dimensions (DWH, mm):812 x 901 x 1079...
France, Vedène
... information while minimizing potential noise (losses, interactions, barriers). You are now familiar with the Shannon and Weaver communication theory, which can be complemented by Jakobson, Lasswell, or the Palo Alto school. A bit pompous, isn’t it?! The real work lies here: knowing and defining yourself, understanding your clients/personas, identifying the expectations, offers, and demands of each. Once this analysis is completed, we can focus on publishing articles, photos, and videos, scheduling them, testing them, and making them redundant and targeted.
Italy, Casalecchio Di Reno
... well as strict controls of all the production steps are applied in order to replicate precisely the mathematical model of the tooth profile (software such as GAGE and Komet are used). The use of modern Gleason Phoenix CNC gear cutting machines and Klingelnberg and Remaut CNC lapping machines with a 100% gear final check in combination with vibration analysis, allow to obtain highquality lapped Gleason gears that will satisfy the most demanding customers...
France, Saint-Quentin-En-Yvelines Cedex
...By upgrading your SYNAPT MS instrument to full HDMS capability, you can leverage high-efficiency ion mobility separations (IMS) to extend your research into a new dimension. The upgrade to HDMS will allow you to differentiate samples based on their size, shape, and charge, in addition to their mass. This provides you with a range of new or enhanced analytical advantages, such as conformational analysis, the ability to separate different classes of compounds, the elimination of background noise and interferences, and the capability for comprehensive structural characterization.
Switzerland, Schwyz
... Counter Additional software available: Direct determination of the 1000 Kernel Weight Analysis of the size of the counted particles: Particle Size Analysis Conveyor bowls The parts to be counted are transported in a vibrating conveyor and are singularised by means of a sorting element. Both the conveyor bowl as well as the sorting element can be selected among different variants , depending on the...
Germany, Wetzlar
...The Leica EM RAPID milling system for pharmaceutical research enables sample preparation for the analysis of active ingredient distribution in solid dosage forms. The instrument uses a tungsten carbide or diamond milling cutter to uncapsulate pills without contamination and features the following characteristics: variable cutting speeds ranging from 300 to 20,000 rpm, layer roughing, low-noise suction, and filtration with a HEPA filter, along with one or more sample holders.
Germany, Weiterstadt
... capabilities, DynaFiz can reliably measure even in environments that are too turbulent for conventional phase-shifting techniques. The high-resolution, low-noise camera and optical magnification of the DynaFiz interferometer allow for clear representation of average spatial frequencies on the surface of a test artifact. • Dynamic capture in air turbulence and strong vibrations • Clear representation of average spatial frequencies through an optimized optical system • Real-time Zernike analysis with LivePhase™...
Germany, Leipzig
... employed AD converters ensures a wide range of applications. The Apollo PCI-Express measurement cards are particularly suitable for: - Data acquisition and data analysis - Customized multi-channel VibroAcoustic measuring devices - Monitoring of noise and vibrations - Condition monitoring of machines and systems - Acoustic camera - Quality assurance - Research and development...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play