...UniBar pressure sensors measure the relative pressure of various media in closed systems within the range of -1...600 bar. • Easy operation via the display • Flush-mounted for easy cleaning • Space-saving process connection due to small pressure membrane • Highly visible switching status indicator UniBar pressure sensors measure the relative pressure of various media in closed systems within the...
... costs for application-specific, critical sensors\n» Modules can be exchanged to meet all requirements\n» Extremely durable despite constant process temperatures up to 177 °C (350 °F)\n» Easy to use and adjust without additional tools\n» Self-diagnosis ensures optimal functionality\n» Available as absolute or relative sensor (vacuum compatible)\n» Designed to withstand the harshest environments\n» Airtight sealing system prevents internal condensation"}...
Switzerland, Reinach Bl
...Economic electronic pressure switch with fully welded metal cell - The Ceraphant PTP33B is an attractively priced electronic pressure switch featuring a metal process membrane for measuring and detecting absolute or relative pressure. The pressure sensor, with its compact design, is extremely stable and resistant to overpressure. The PTP33B, with a stainless steel housing, is certified 3-A and EHEDG.
... ■ Integrated angle-of-rotation sensor, not subject to wear ■ EAC declaration (upon request) Options ■ Approvals/Certificates - Calibration certificate - Explosion protection for gases and dust - Certificate of measuring equipment for Russian Federation - Material certificate as per EN 10204-3.1 ■ The electrical zero can be corrected by holding a ferromagnetic object to a marked location on the...
France, Rambouillet
... RJ11 port, the STE2 LITE can monitor up to four values from external sensors, including relative humidity, CO2, VOC concentration, 4-20mA current, and much more. It is possible to daisy-chain multiple RJ11 sensors for extended monitoring. Furthermore, a single physical sensor can measure multiple values, such as temperature in degrees Celsius and humidity percentage, which counts as two distinct values.
Germany, Altena
... Number of switching outputs: 1 Housing material: Zinc die-cast Design of electrical connection: M8 connector Design of switching output: PNP Design of switching function: Normally open contact Degree of protection (IP): IP67 Sensor surface (active): Central area/circuit Position of sensor surface: Center of the device Mounting access, cylinder groove: from above Switching frequency: 1000Hz Ambient temperature: -25 ... 75°C Operating voltage: 10 ... 30V Voltage drop: 2V No-load current: 15mA Rated switching current: 150mA Relative repeat accuracy: 0.1mm...
Austria, St. Ruprecht An Der Raab
... data can be added. You also have the possibility to use the Autolog function. This function automatically saves measuring values in adjustable time intervals. Relative air humidity :0 to 100% Resolution :0.1% RH Calibration RH:10 to 90% +/-1.5%RH (at 25°C) Dew point :-55 to +60°C Resolution Dew point: 0.1°C, -67 to 140°F...
Belgium, Temse
...This self-calibrating CO2 sensor measures CO2 as well as temperature, relative humidity and ambient light conditions. It needs a 24 VAC supply voltage. This sensor can also directly control an EC-fan, AC fan speed controller or frequency inverter. It has 1 single analogue / modulating output depending on the highest measured value for temperature, humidity or carbon dioxide. If you only want to...
Germany, Geraberg
... PC cards or PLCs. The LKM 458 has a typical accuracy of +/- 0.5°C and 3% r.H. The sensor is delivered pre-calibrated. Minor adjustments can be made on-site using two controllers. It is important to ensure the correct positioning of the sensor. The protection rating is IP64. The measurement range is -20...80°C for temperature and 0..100% for relative humidity. The sensor can also be supplied for 0...50°C.
...The AtmoSense™ is a flexible process analyzer designed to provide real-time measurements of process gas variables in a wide variety of atmosphere control applications. The AtmoSense™ is available with a range of sensors and options to provide accurate measurement of either dew point, relative humidity(%RH), methane(CH4), propane(C3H8), hydrogen(H2), carbon monoxide(CO), or carbon dioxide(CO2). Choose NEMA enclosure for permanent mount or pelican case with battery for portable use.
France, Aubagne
...Typical applications of the Radar III for agriculture include monitoring tractor slip, as well as calculating the forward speed of tools such as seeders, sprayers, or spreaders. This sensor is ideally designed to be integrated into regulation systems that require speed information for determining the dose to be applied (DPAE). The sensor records displacement relative to the ground. It can be...
...The HMC03M is designed for a quick response time, even at very low temperatures (T) in the upper atmosphere. The HMC03M combines a capacitive sensor for relative humidity (rF) and a heating resistor on a silicon substrate. The heater ensures rapid recovery of the humidity sensor after dew or icing conditions. This achieves excellent measurement performance for high-end weather observation. Features Very fast response time even at low temperatures High sensitivity and excellent linearity Quick recovery after dew or icing through heating...
France, Blotzheim
...cutting speed 20 to 120 m/min via electronic variator. Sawing arm descent on 2 vertical columns. Sawing arm descent via hydraulic cylinder (progressively adjustable). Sawing arm ascent via hydraulic cylinder. Adjustment of the upper stroke. Force sensor on the guiding arm to limit descent speed when the blade encounters wider sections (or harder materials). Blade inclined at 2° relative to the horizontal. Blade stop at the end of the cut. Programmable hydraulic vice with large stroke...
France, Chambray Les Tours Cedex
...Download the product sheet Main features Measuring ranges -1 ... 0 bar to 0 ... 200 bar Annual stability ≤ 0.3% EM / Year Accuracy (20 °C) (linearity, hysteresis, and repeatability according to the BFSL line) ≤ ± 0.5% EM (BFSL) Technical data Measuring principle Thick film ceramic Measuring ranges -1 ... 0 bar to 0 ... 200 bar Pressure type Relative Accuracy (20 °C) (linearity, hysteresis, and...
...It is a very effective spray produced from special solden mixtures for internal and external cleaning of the carburetor. It is also used to clean heavy oil and spherical carbon deposits such as suction flaps, slowed enteles, throttle, and splitter. It does not damage the oxygen sensor and catalytic convector. Since the material has a relative lubricating function, it enables the cleaned moving parts to work better. It provides great convenience in removing oil and gasoline residues for the workers who assembly and does the service-maintenance works.
France, Toulouse Cedex
...electrical resistance sensor: 8mm, replaceable measurement range: wood: 1% ~ 45% other materials: 0.1% ~ 2.4% resolution: wood: ±1% other materials: ±0.1% accuracy: ± 3.0% RH power supply: 3 x CR2032 (included) operating temperature: 0°C ~ 40°C ambient relative humidity: 0% ~ 85% dimensions: 139 x 47 x 25mm weight: 100g Ref: DVM125...
Germany, Hohen Neuendorf Ot Bergfelde
...The SITRANS P200 is a compact single-range transmitter for measuring absolute and relative pressure. This series uses two types of pressure sensors: two stainless steel sensors and one sensor with a ceramic diaphragm. This makes measuring process pressure, absolute pressure, and hydrostatic pressure a breeze. The pressure determined by these sensors can be converted into either a 4–20 mA or a 0–10 V signal.
... optimal sensor can be selected. The measurement results from the different sensors are presented in a common coordinate system. For this purpose, the positions of the sensors are pre-measured relative to each other. This allows us to combine the results from various sensors to measure features that cannot be measured well or at all with a single sensor. Optical and tactile measurements can be alternately used in combination without interrupting the ongoing CNC measurement. It is this combination that enables us to address most industrial tasks for you...
... velocity, and shaft vibration sensors - Speed sensors - Sensors for measuring relative strains - Sensors for measuring absolute positions Hofmann on YouTube: https://www.youtube.com/channel/UCKAWJO4lWIStI4Yi-Vqc0VQ...
Germany, Rheinbach
... values of CO2, temperature, and humidity. - Different colored LEDs (blue, yellow, and red) additionally indicate the current indoor air situation. - Reliable CO2 sensor ensures good long-term stability. - A dimmer function regulates the brightness of the LEDs and contributes to energy savings.
... pressure transmitter series are used. Advantages: + High overpressure safety even in the smallest pressure range + Robust measuring sensor thanks to excellent synergy of membrane technology and ceramic element + Easy installation and commissioning + Maintenance-free + High protection class Medium: Air and neutral gases Pressure range: -5 ... 5 mbar / 0 ... 10000 mbar Output: 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA Accuracy: < 1.0% FS Electrical connection: Screw terminals Pressure connection: Hose fitting conical 4 ... 7 mm or quick coupling Installation: Screw mounting...
...Compact sensor for humidity and temperature in harsh conditions for measuring relative humidity and temperature with capacitive Mela® humidity sensor element with current or voltage output Compact sensor in stainless steel housing IP 65 The sensors of the VC and VR series are compact rod sensors. They can be used in a variety of applications and have been specifically designed for use under extreme conditions. Due to their design, they are suitable for measuring moisture balance in bulk materials and masonry.
... regular maintenance. PMCG devices are able to maintain relative humidity from below 25% up to 60%, at ambient temperatures of below 0°C up to 40°C. The newest models are equipped with a WiFi connection to internet. Achievable RH level:<20% – 60% Permissible Ambient Conditions for Operation:<0°C – 65°C Sensor Accuracy:±3% Sensor Repeatability:0.5% Power connection:Universal 100-240 VAC, 50-60 Hz, 1.5A Power Consumption:30 W Noise Emission:< 25 dB Weight:1.6 kg...
Netherlands, 's-Hertogenbosch
... moisture meter. The HT-4000, a fast response stand-alone thermo-hygrometer has the same fast acclimating RH/T sensor found in our popular TotalCheck and Navigator Pro 3-in-1 moisture meters. Your Benefits: Bright, clear digital display Relative Humidity Range: 0% - 100%, sensor can be used for in-situ concrete testing following the ASTM F170 standard Temperature Range: -40°C - 124°C (-40°F - 255°F) Dew Point Range: -40°C - 80°C (-40°F - 176°F) GPP Range: 0.1 - 3820 GPP (Grains Per Pound) GPK Range: 0.01 - 545 GPK (Grains Per Kilogram) Vapor Pressure Range: 0 - 7 PSI (Pounds Per Square Inch...
France, Fontaines Les Gres
... (11 ± 1) x 106/K (spring steel) Temperature range Ambient temperature 20–70°C Storage temperature 40–70°C Assembly Installation using the preaffixed doublesided adhesive tape must be carried out according to the enclosed user information. On request Other lengths from 0.1–100 m, in increments of 0.1 m. Note Relative humidity 100%. Dewing is permissible. Drawing reference 1) Cover band A = 0.176 mm 2) Magnetic tape M = 1.0 mm 3) Carrier band T = 0.3 mm 4) Adhesive tape K = 0.1 mm 5) Required tape length = measuring path + L + 2 x B 6) Measuring path Reference:21725...
Belgium, Mornimont
...-speed fan, this device can handle up to 800 m³ of volume at 50% relative humidity. Technical Data Humidification capacity: 2.6 L/h Airflow... Humidification capacity: 2.6 L/h Recommended volume: 800 m³ max Power supply: 1 x 230 V Power consumption: 125 W Water reservoir capacity: 50 L Noise level: 32 - 44 dBA Built-in adjustable hygrometer: Yes, remote control Weight: 24 kg Dimensions HxWxD (mm): 620x755x365...
Spain, Tobarra (albacete)
... Relative Humidity Probe and base 15 ... 90 % R.H. Liquid Resistance Probe and Base Lubricating oil, light oil, or 5% saline solution Ingress Protection Probe Water, oil, and dust, according to protection class IP67 Base Rain with wind (the battery compartment must be closed). Do not submerge in water...
...The heat capacity measuring insert is intended for measurement of the heat capacity temperature dependencies in constant magnetic field. In this insert the adiabatic method is used. The inner sample holder is equipped with the resistive heaters, resistive temperature sensors and Hall sensor. The heat capacity measurement insert characteristics: - relative measurement accuracy of heat capacity: 3 %; - sample dimensions: a rectangular bar 4×5×2.5 mm; - temperature interval – from 80 to 370 K; - magnetic field interval – from 0.02 to 2 T.
...The high-contrast and easily readable large number color display shows the relative humidity, temperature, and dew point. Laser for non-contact surface temperature measurement. A calibration function allows for long-term use without loss of measurement accuracy. Switchable °C / °F. With permanently attached sensor. Measurement range: +20 - +50 °C or < 90 % r.H. Accuracy: Temperature: +/- 0.2 °C...
...) achieves an effective quality improvement. Control results of ± 4 I-Units relative to the respective target curve are realistic. With our detailed knowledge of the interplay between measurement, control, and rolling framework, we are among the few manufacturers that realize complete control systems for strip flatness – from the sensor to the actuation of the actuators. From the tilting of the rollers to the combination of tilting, bending, shifting of the intermediate rollers, and zone cooling, we master the entire spectrum of flatness control.