Germany, Zeuthen
...Do you own a measuring device from HGL Dynamics and want to use it to obtain reliable measured values in the future? In this case, calibration is essential. We will advise you on the selection of the right calibration method for your amplifier. In addition, we also offer a factory calibration of your HGL measuring devices according to your specifications. All calibration references we use are traceable to national and international standards. We will be happy to prepare a suitable offer for this.
Germany, Ettlingen
... supplied with a factory calibration certificate. Excellent long-term stability is achieved through the use of appropriate materials. Of course, a repair and spare parts service is available for many years. The integrated electronics produce a signal voltage that is transmitted to the radiometer. Various sensors can be used with a radiometer by means of internal electronics. Dimensions:Ø 40 mm, h 35 mm Weight:150 g Cable length:2 m Operation temperature:0 to 40 °C Signal voltage:0 - 2 V...
... All configuration data editable High measurement accuracy Space-saving in the control cabinet Variable adjustable cutoff frequencies Linearity deviation: < 0.005 % of full scale. Measurement rate: 14400 measurements/s. Sensor type: DMS / potentiometer / DC/DC/incremental sensors Interfaces: screw terminals Sensor supply - DMS full bridge: 2.5 V / 5 V / 10 V configurable, short-circuit proof Sensor supply - potentiometer: 5 V Protection class: IP20 Supply voltage: 11 ... 30 V DC. Galvanic isolation, reverse polarity protection, overvoltage protection...
Germany, München
... implementation, as they no longer have to deal with time-consuming calibration. • High profile speed of 14,000 profiles/s and up to 28 million points/s • High resolution of up to 0.3 µ • Compact form factor • X measurement range of 10-1022 mm • Z measurement range (height) of 5-878 mm • Laser wavelength blue 405/450 nm, red 650 nm The new Q5 laser scanners also incorporate additional useful product features, such as the possibility of a master-slave configuration for multi-scanner operation and more.
Germany, Langenbrand
... sensor can be installed at a difficult accessible places. This ensure the easy handling. With the easy to use calibration function (calibration button), our customer can take spectra's for the calibration with the calibration button at the measurement place and read the internal stored spectra's with the calibration software. Due to this function and the open calibration system our customers can expand independent an existing calibrations or create new calibrations.
Matching products
Hk7
Hk7
Other products
Hk13
Hk13
Germany, Gschwend
...Mobile test device for detection of the maximum torque (drag indicator mode) and for the detection of the power range (constant load) of motors in dental and dental surgical application area. arbitrary loading curves endurance test speed ​​measurement in aluminum case permanently installed Calibration disc and calibration will be in the trunk.
Germany, Hamburg
...The PR 6221 series load cells have been specifically designed for use in truck scales. Exceptional precision and long product lifespan reduce service and calibration costs, helping to minimize downtime. When combined with the Connexx® converter, the PR 6221 sensor becomes a digital solution. - Exceptional reliability thanks to German quality - Precise measurement results due to the special...
Germany, Wernau
...High-precision angle measurement system with +/-0.1 arcsec accuracy for measurement and calibration applications The signal sampling is based on an interferometric principle (Laserscale). The division period is 1µm, and the generated signal period of the output signal is 250nm. By using six read heads in a special arrangement, scale errors are automatically compensated. Measurement values can be...
Germany, Ilmenau-Unterpörlitz
... comparison sensor, displays it on the screen, and adopts its calibration values. Additionally, a digital system sensor from the SUV 19 series can be connected for verification against the comparison sensor. Through the device menu, adjustments or corrections of the system sensor based on the comparison sensor's measurement value are possible. The measuring device is battery-operated and features a two-line LCD display that shows, among other information, the irradiation intensity in Wm-2. The four measurement ranges are switched automatically. The device is easy to operate with three buttons.
...logging, and calibration • 2-year warranty Measurement range: -40 °C to 2250 °C (depending on model) Ambient temperature: -20 to 85 °C (up to 315 °C with ThermoJacket) Spectral responses: 8 to 14 µm; 7.9 µm; 5 µm; 3.9 µm; 3.43 µm; 2.2 µm Optical resolution: 7:1 to 70:1 (depending on model) Response time: 30 ms to 150 ms (depending on model) Interfaces: Analog (4..20mA|0/4..20mA|0..10V|thermocouple J/K), USB, RS485, alarm output, trigger input Power supply: 12 to 24 Vdc; 20 to 48 Vdc, 100 mA (depending on model) Protection: IP65 (NEMA-4)...
...Thermal Mass Flow Measurement and Control Key Features*: Measurement and Control Ranges: + Flow Meters: 0 – 5 sccm to 0 – 15,000 slm (N2 Equivalent) + Flow Controllers: 0 – 5 sccm to 0 – 10,000 slm (N2 Equivalent) + High Measurement Accuracy: ±(0.2% of Full Scale + 0.5% of Reading) + High Reproducibility: ±0.05% of Full Scale + Short Response Times + Low Pressure Drop + Metal or Elastomer...
Germany, Duisburg
... transmitter offers high accuracy and measurement stability under all process conditions. KROHNE is the only manufacturer of process instrumentation to carry out a total 3D linearization of its differential pressure transmitter. For a robust and accurate differential pressure measurement, even under changing process conditions, each OPTIBAR DP 7060 differential pressure transmitter is linearized in...
Germany, Springe-Eldagsen
...Ensure the high precision of BlowerDoor measurement technology through regular calibration of pressure measuring devices and measuring fans. The accuracy of the pressure measuring devices (± 0.9% or ± 1%) as well as the accuracy of the measuring orifices significantly exceed the legal minimum requirements. Both factory calibration and calibration with DAkkS certification are subject to high...
Germany, Kirchzarten
... calibration of the measurement quantity pressure. Calibration Certificate: DAkkS or ISO Calibration Items: Differential pressure transmitters, calibration devices, absolute pressure transmitters, and portable manometers Absolute Pressure: from 0.25 bar to 20 bar in gases Overpressure: from -10 mbar to 20 bar in gases (negative and positive) Standardized Procedures: e.g., DKD-R 6-1 Optional: Adjustment of the calibration item...
Germany, Steinenbronn
...Our calibration laboratory offers factory calibrations for all types of flow measuring devices, as well as for the measurement parameters of pressure, temperature, and humidity. We can perform factory calibrations both in our calibration laboratory and on-site at your location. The calibrations are subject to the recalibration and traceability requirements of DIN EN ISO 9001 and are always carried out by comparison with measuring devices that are regularly recalibrated at a DAkkS-accredited calibration facility or at the Physikalisch-Technische Bundesanstalt (PTB).
Germany, Thierstein
... bar up to 0 ... 6000 bar — accuracy: 0.5 % (opt. 0.25 %) FSO — adjustability of offset and span via front sided potentiometers — pressure port 9/16" UNF — 80 % calibration signal with MIL / Bendix plug Optional Features: — IS-version Ex ia = intrinsically safe for gases — pressure port M20 x 1.5 and M16 x 1.5 — accuracy according to IEC 60770: 0.25% FSO...
Germany, Kassel
...- Consulting on the introduction and implementation of a measurement equipment management system according to DIN 32937. - Consulting and creation of work instructions/process descriptions as well as calibration instructions in the field of measurement equipment management. - Training employees in the handling of measurement and testing equipment. - Taking on measurement tasks on-site for the measurement quantities of length (e.g., component measurement), pressure (e.g., manometers), torque (e.g., torque wrenches, torque screw tools), and force (e.g., industrial scales).
Germany, Rheinböllen
... effort. - Compliant with ISO 9000 ff., ISO/TS 16949, VDA, QS 9000, and HACCP - VDA 5 suitability proof - Standard-compliant MSA / Measurement Capability Study (MCS) - Representation of test plans according to VDI/VDE 2618 - Dynamic usage/location-based testing intervals - Complete test histories for characteristics and measuring instruments - Evaluation of measuring instrument suppliers - Integrated test plan management - Test histories and measuring instrument lifecycles with usage and storage locations - Extensive standards and fit libraries integrated - Manufacturing-supporting calibration...
... Monitoring of second wavelength: 300-400 nm, 340 nm or 420 nm including beam splitter, dual filter housing and lamp calibration Special locking casters and frame modification WXView (Weather View) Data Acquisition System 2-tier rack - 60 specimen positions...
... for short, is used for the precise measurement of air or gas volume and mass flows of 100,000 m³/h. The core of the VMF® system is the FlowProcessor, a PC system with the corresponding data acquisition hardware. Venturi nozzles convince by a low remaining pressure loss and are suitable for flow measurement of gases with high temperatures. The software developed under LabVIEW is operated either via touch screen or with mouse and keyboard.
Germany, Betzigau
...• The inverse frequency technology enables very precise measurements even at low levels • Change or media with low dielectric constant • Measurement range from 1.66 pF to 3300 pF with a minimum of 3.3 pF allowed • Measurement with high accuracy • Active shielding technology allows measurements even with attachments or deposits on the container wall • 2-wire sensor with 4...20 mA output signal...
Germany, Oberrot
...Special stainless steel high-gloss polished plastic case Mass standards - Class E1 Adjustment, testing, calibration, and verification instruments for quality assurance of scales with a step count > 1,000,000 according to DIN EN ISO 9001ff, etc. For the calibration and verification of weight pieces of Class E2 according to OIML R111 and E08. For high-precision weighing or comparative measurements...
...In addition to service and maintenance, calibrations are also carried out on-site by our staff. Following this, the evaluation of all measurement data takes place, and the calibration certificate is created. Whether it's maintenance, calibration, leak testing (Chemical Climate Protection Regulation), insulation protective conductor testing (DGUV) according to DIN 701-702 as well as DIN 60204-1...
...The calibration support is used for semi-automatic measurement range calibration of eddy current sensors at the Konrad Converter.
Germany, Bad Wünnenberg
...* Comfort level indicator with adjustable alarm values * Acoustical and visual alarm function with adjustable limit * Large display to show CO2, humidity, temperature, date / time * Max/Min-values * Infrared-CO2-measurement * Automatic calibration function * Non-volatile memory...
... trend, making data available for archiving in the accompanying process documentation - Data exportable to Microsoft® Excel® - Cost savings by avoiding excessive heating times and simplifying equipment calibration (compared to thermocouples) - Equipment-independent: Suitable for standalone operation for all types of equipment; can be integrated into process control MarView for MARQUIS systems - No need for compatible sight glasses or modifications to equipment (as required in pyrometry)...
Germany, Gießen
...More information through the measurement of weight change and heat flow using instruments for simultaneous thermal analysis. The TGA/DSC 3+ provides reliable results using a TGA balance from the world’s leading provider of weighing technology. Features and benefits of the device include position-independent weighing, automatic internal calibration weights, a large measurement range, a...
... analog output. The current output is read back by the F01 to ensure the output signal is emitted correctly. To be able to use the F01 in many applications, users can select different pressure connections. The electrical contact takes place via a 5-pole M12 connector. Through the calibration of the transmitter via temperature, a total accuracy of 1 % FS can be achieved within a range of 0...80 °C...
Germany, Villingen-Schwenningen
... enables a permanently oil-free compressed air supply. —OIL-Check 400 – Residual oil measurement of vaporized residual oil content from 0.001…2.5 mg/m³, 3…16 bar. Highly accurate PID sensor, integrated mini-catalyst for zero-point calibration —Permanent, highly accurate residual oil measurement (oil vapor) with PID sensor (Photo-Ionization Detector) —Long-term stable measurement results through automatic zero-point calibration. The integrated mini-catalyst reliably generates a defined reference gas for zero-point calibration.

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play