... on a second display directly below the main display. With a low measurement error of 0.1%, the indicator meets higher accuracy requirements. Optionally, it is possible to monitor up to 4 limit values and deliver the results to the control system via relay or transistor outputs. This makes the process value indicator suitable for classification, as well as control and regulation tasks. When an...
Germany, Buchenbach
...Position indicator compatible with bus system featuring a two-line LCD display to show both nominal and actual values. Includes an additional LED for clear indication of positioning status. It is used to monitor format changes, reduce setup times, and increase machine efficiency. Electronic position indicator with plug-in connection for magnetic sensor. Backlit display for optimal readability...
Germany, Heinsberg
...If there is no water in the tank, the humidifier automatically shuts off, and a flashing signal indicates that it needs to be refilled with water. *Optional equipment B 250: Automatic water source, water monitor, safety pressure hose Summary of some technical details of the B 250: Max air flow: 500 m³/h Connection voltage: 230 V/50 Hz Power consumption: 0.050 kW Approximate evaporation capacity: 28.8 L / 24 h (for 23 °C / 24 % RH) Blowing levels: 2 Application in spaces up to approx.: 450 m³ Applications: air Other features: compact...
Germany, Bad Schussenried
...Features: - Filter performance depending on size, application area, and type of filter fleece up to 580 l/min per filter module - Average filter fineness (separation grain size) variable by selecting the type of filter fleece - Fleece monitor with indicator light for fleece shortage notification - The liquid distributor is equipped with a coarse particle separator - Float switch with control...
... chamber temperature and humidity and compensates for changes in ambient lab conditions SmartLight Monitor TM verifies that correct light capsule is installed Filter combinations available to meet all common test methods Air intake dust filter CS-7 xenon lamp cooling system Chamber viewing window in door Universal electrical configurations to meet local frequency, voltage, and electrical requirements...
...) Sampling rate:1024 pixel per scan line (2048 for CS212) Ambient operating temperature:-40...45 °C (no direct sunlight) Ambient temperature - position indicator:-25 to 230 ºC Zone alarms:48 software, 3 hardware (PC independant) Kiln rotation rate:Up to 10 rpm LRM accessory:Supports up to 6 tires Fan Control accessory:Supports up to 16 fans per module (48 total) Communication:Ethernet TCP/IP Analog output:3 x 4 – 20 mA Alarm output:Relay, contacts: 30 V, 1 A Power supply:24 VDC ± 25 %, 1 A...
Germany, Kirchhundem
...By adding an indicator to the silica gel, one can monitor the water absorption of the product through a color change. For instance, with an orange gel, the color changes from orange to a light black-green as water absorption increases. This makes it very easy to determine whether the silica gel in use is exhausted and needs to be replaced, or if the used silica gel needs to be regenerated...
...deltaP® differential pressure indicators and switches are used to monitor a pressure difference, e.g., for monitoring the contamination of filters, and signal this both visually and electrically.
Germany, Rheinbach
...A good indoor climate is the most important prerequisite for our well-being in enclosed spaces. Therefore, high-quality indoor air is becoming increasingly significant. The CO2 indicator including temperature and relative humidity display. - LED CO2 traffic light shows air quality via colored LEDs - Mute button to activate/deactivate the alarm - LCD backlight for easy reading in the dark...
Germany, Mühlheim
... sensors, yet still very reliable. The flow monitor cost-effectively monitors a minimum or maximum flow in your application. Due to its compact design, it is universally applicable. The internal piston moves in relation to the flow rate against a spring. At a defined, adjusted operating point, the integrated reed contact switches. Thanks to its return spring, the flow monitor operates largely independently of its position.
Germany, Erligheim
... cable with a Schuko plug. Features: • Reduced power consumption due to electronic holding current reduction • Prevention of valve internal parts from seizing through automatic daily valve closing pulse • Nominal diameters from DN10 to DN50 • Connections G1/2 to G2 • Piezo buzzer alarm • LED operating voltage indicator • Drinking water approval available upon request Function: After switching on the mains voltage, the electronics open the solenoid valve. The sensor detects a water film of approximately 0.5 mm and sends a signal to the control electronics. The valve is then closed.
...The ND 280 position indicator for an axis is suitable for simple measurement and positioning tasks, such as the delivery at a circular saw, the lift of a press, or the position of an additional rotary table on a machine tool. Design The ND 200 series is equipped with a robust aluminum die-cast housing. The splash-proof pressure point keyboard is workshop-compatible. A large, graphics-capable TFT monitor is used to display measurement values, status indicators, and the softkey bar.
Germany, Fellbach
...The indicator brings simplicity to plasma evaluation. Industry-first technology can realize evaluation of in-plane distribution and 3D objects. Very suitable for daily plasma control of machine-to-machine differences to stabilize product quality and increase efficiency.
Germany, Nidda
...LINAK BA001: High-performance battery solution (2.15 Ah) for linear actuators. Ideal for carts, chairs, and TV/monitor stands with LED status indicator and acoustic alarm.
Germany, Germering
... - Thermal shut-off device "T" (TAE) for automatic shut-off of gas flow when the temperature rises above +100 °C - Manometer for leak testing, e.g., during cylinder change Conformity: EC type examination according to DGR Technical Data: Maximum allowable pressure: PS 16 bar Note: When connecting consumption devices with a total connection value of up to 1.5 kg/h, the use of a gas flow monitor can be omitted. Low-pressure regulator type EN61-DS, straight outlet KLF x G 1/4 LH-KN 50 mbar 1.5 kg/h...
... gauge DP 900 serves to monitor the differential pressure of filter systems, measuring systems, valves, coolers, heat exchangers, in petrochemical, as well as in gas and air systems. Preferably, the DP 900 is applicable for air and gas technical systems. The gauge housing made from aluminum is designed compact and robust. It is pressure-resistant up to 350 bar. FUNCTION A determined path of a freely movable piston measures the differential pressure. The piston retains against a compression spring. The magnetic spool-measuring device unit is been installed to the main housing.
... current • As option with analogue output • Broken wire detection • Protection against manipulation by sealable transparent cover over setting switches • Width: 52.5 mm Function:Residual current monitor, Type B Type of voltage:AC; DC Adjustable measuring ranges:0,01 ... 3 A Enclosure design:Installationsverteiler Width:52,5 mm Type:RN 5883...
... functionality. For the first time, in addition to the known features, a Service Life Measurement Device (SLM) for maintenance-free lead batteries has been integrated. This Service Life Monitor provides a reliable overview of the remaining service life of the lead battery and notifies the necessary replacement after the service life has expired via a light indicator and potential-free changeover contact.
... * Equipped with built-in charger and battery indicator to monitor battery charge status * Steering wheels and fork rollers made of polyurethane * With a one-piece lift cylinder = better stability and reduced wear Load capacity: 1000 kg Lift height: 800 mm...
... available with factory-fitted Particle Monitor LPM II and Oil Condition Sensor OCS with Oil Condition Display OCD. Motor/Pump Unit ▪ Available in different configurations Clogging Indicator ▪ Visual clogging indicator Replacement Filter Elements ▪ Filter Elements type SRM Construction ▪ OLS-CM with control box and preparation for installation of LPM II, OCS sensor with OCD display Nominal Flow Rate ▪ 2,1 ... 17 l/min / .55 ... 4.5 US GPM Port Connection ▪ G3/8, G1/2, G3/4 and 18 L Materials ▪ Anodised Aluminium Media Compatibility ▪ Mineral and lubrication oils, other fluids on...
Germany, Bremen
... implementing projects is our daily business. Another focus is the development of modified products for a wide range of projects. Our competent handling of challenges makes us your contact in the field of lighting. To monitor the lighting systems, Lanthan has developed a database-oriented solution. The lighting system reports status changes and periodic messages to our servers via GSM or Ethernet. The data is evaluated there, and fault notifications are sent, for example, via email.
Other products
Obstacle Fire - HF10
Obstacle Fire - HF10
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store