...These switches are suitable for DC applications as well as for photovoltaic applications. Feel free to contact us regarding our extensive product range.
...etc., all variants also bistable. Optional closed contact housing, auxiliary switches with silver-plated or gold-plated contact surfaces, suppression diodes, bistable, holding angles suitable for your installation.
... protected from short-circuit and overload. The short-circuit current is limited by the output transistor switching off inthe event of a fault. It will automatically reset as soon as the fault has been remedied. The switch is available with ground-connected, plus-connected or potential-free DC switching output. The switch is open in the event of power failure or disconnection of the power supply, independed of the switching function. It is available both as normally open (NO) or normally closed (NC) switch.
... All our controls impress with their ergonomic design, are easy to operate, and can be individually adjusted or programmed. Discover all the performance details and advantages on the product pages! Radio Control D3: Extremely long battery life, Quick transmitter switching Radio Control DRC-DC: Handheld transmitter for controlling up to three axes Radio Control DRC-MP: High safety due to greater...
Germany, Bad Teinach-Zavelstein
A wide standard range of industrial sensors in the field of inductive, capacitive, magnetic, and optical switching systems, light barriers with corresponding accessories (connectors, junction boxes, reflectors, mounting brackets, etc.). The focus here is on process-safe and cost-effective solutions to the tasks at hand. Collaboration with national and international distribution partners. Of cours...
Germany, Heiligenstadt I.ofr.
...Type UPS Module Category DC Power Supplies Design UPS Module Application The UPS module, in combination with regulated or unregulated SBA DC power supplies, provides an uninterrupted 24 V DC power supply. In the event of a failure of the 24 V DC control voltage or a power outage, it seamlessly switches to battery backup operation to prevent: - hazardous conditions for operating personnel...
Germany, Minden
... is 500 mm (special strokes available upon request). The drive consists of a 24 V DC geared motor, which is typically powered by a control/transformer unit (230 V AC/120 V DC). Manufacturer: RK Rose+Krieger Country of Manufacture: Germany Lift: up to 498 mm Lifting Speed: 8 / 16 mm/s Lifting Force: up to 3,000 N Brand Name: Multilift Protection Class: IP 20...
... are also available with zero voltage reset. Motor drive: Actuating force: 800N; Motor voltages: 24V AC/DC, 230V, 110/120V; Control: 3-point; (0)2-10V; (0)4-20mA Nominal diameter: DN 15 - DN 50 Nominal pressure: PN 40 Materials: Stainless steel 1.4408 Temperature: -30°C to +220°C; Connections: Whitworth pipe thread; NPT thread Application: Gases, vapors, liquids Protection class: IP65...
... modular industrial heating system. The setting range from 0% to 100% can be selected individually for each channel. By using state-of-the-art semiconductor switches, the output stages achieve high efficiencies, at working frequencies up to 25 kHz. Functions:Integrated power measurement, short circuit detection, DC link monitoring, automatic frequency tunin Load type:specific induction coils...
... All configuration data editable High measurement accuracy Space-saving in the control cabinet Variable adjustable cutoff frequencies Linearity deviation: < 0.005 % of full scale. Measurement rate: 14400 measurements/s. Sensor type: DMS / potentiometer / DC/DC/incremental sensors Interfaces: screw terminals Sensor supply - DMS full bridge: 2.5 V / 5 V / 10 V configurable, short-circuit proof Sensor supply - potentiometer: 5 V Protection class: IP20 Supply voltage: 11 ... 30 V DC. Galvanic isolation, reverse polarity protection, overvoltage protection...
...EGE amplifier for Ex proximity switches complement the intrinsically safe EGE sensors. They are used for switching point adjustment and provide functional and output indications as well as the output signals. They also provide the 30 V DC or 127 V AC or 230 V AC power supply. The devices can be set up intuitively using a potentiometer and have a cable break and short circuit monitoring feature. The NC/NO contact output functions can be adjusted. The analysis devices are intended for top-hat rail assembly in a control cabinet in the non-explosive area.
Germany, Neuss
... - 240V AC/DC Torque: 10NM - 300NM Mounting Standard: ISO 5211 Connection (Shaft): Square, Double Flat Position Indicator: Dome position indicator Limit Switches: 2 additional potential-free limit switches Manual Override: Yes Options: DPS 4-20mA/0-10V (Digital Positioning System), BSR NC/NO (Battery Safety Pack)...
...and protective cabinet applications Long service life Rich optional additional equipment Application Area The proven Ritter load break switches were originally designed for the subway construction in Munich for the 1972 Olympic Games. Since then, public transport companies worldwide have shown interest in a DC load break switch, and currently, the RGL load break switch is in use on all continents with over 6,000 units deployed globally. The RGL switch can be used with all DC power supplies with busbars or overhead lines.
Germany, Nürnberg
...• Barthelme LEDlight flex in various shades of white, brightness levels, and RGB, individually switchable via separate switches • the logo is backlit with LEDlight flex RGB • additional space for profile samples or current catalogs • incl. CHROMOFLEX Pro File CV • to directly connect lights or AQUALUC samples, two M8x1 sockets (Monochrome, RGB) and an AR 9-way distributor 24 V DC with a maximum...
Germany, Buchenbach
...High-performance actuator for challenging positioning tasks Easy installation. Stainless steel cable shaft with a diameter of up to 20 mm max. "Manual" translation without a control device using micro switches. 160 W brushless motor, 24 V DC with a long service life. Integrated absolute position transducer on the output shaft. Electrical connection via spring terminals or connector. Integrated drive and positioning system. Integrated fieldbus interface. Integrated spring brake (optional).
Germany, Oerlinghausen
... AC, 115 V AC, 24 V AC Ex Zone 1 marking CE2004 EX II 2G Ex d IIC T6 Gb large torque range large adjustment time range constant adjustment time under load fluctuations large number of limit switches possible electronic position controller ESR-N (integrated in the drive) different motors to choose from: synchronous motor, BLDC, DC motor wide selection of output shafts special shafts possible solid housing made of aluminum maintenance-free gearbox operation in any installation position Housing Housing and cover made of corrosion-resistant aluminum die-cast painted with silicone-free...
...Suitable for 5/3 and 3/2 ways Easy installation Switches quickly and reliably Made of aluminum Long lifespan Technical specifications: A-1_4-24-5_3 Temperature: 0 °C ~ 60 °C Thread: G-thread Pressure: 10 bar Connection size: 1/4" Weight: 300 g Opening cross-section: 6 mm Seal: NBR Switching cycles: 100,000...
Germany, Tuningen
...16mm Point-Illuminated Piezo Switch for Harsh Environments 20mm Outer Diameter 16mm Installation Diameter Point-Illuminated, Various Colors IP68 10mm Depth 100mA, 35V Switching Power (DC) LED Voltage: Red & Yellow: 1.7V; Green, Blue & White: 2.8V (20mA) Pre-wired: 15cm Stranded Wire Anodized Aluminum (in Various Colors) Single-Pole Open Collector (Normally Closed) Finger Dome Shape Vandal Resistant Installation Diameter: 16mm Protection Class: IP68 Housing Color: Natural (Silver) Anodized...
...The sensor module µCAN.1.ai-SENSOR is designed to acquire an analogue signal. It can be integrated directly in the sensor head (18 mm in diameter). Sensor tolerances are adjustable. The sensor signal is linearized and monitored directly in the hardware.Voltage ± 10 V Current 0 mA … 20 mA Accuracy 0.005% (FS) Resolution 16-bit (1 mV / 1 µA) Sampling rate up to 1 kHz Scaling adjustable Sampling rate adjustable Measurement range adjustable Operating temperatures -40°C to +85 °C Supply voltage 9 V DC to 36 V DC Fieldbus CAN Classic / CAN FD Protocol CANopen / CANopen FD / J1939...
... On request, in addition to the magnetic sensor listed here, other versions are also available. Technical Data Magnetic Sensor (M936-1-000) - Switching function: closing - Output technology: PNP - Rated switching field strength: H 1.2 kA/m - Hysteresis: max. 45% of Hn - Operating voltage: 10 to 30 V DC - Residual ripple: max. 15% - Rated operating current: 200 mA - No-load current damped/undamped...
Germany, Karlsruhe
...For direct current applications with a rated operating current ranging from 16 A to 64 A and from 80 V to 1000 V in the usage categories DC-21B or DC-22A. The switches are available in a fully insulated housing, with the option of a red/yellow or gray/black lockable handle. The protection class IP66/67 allows for use in the most challenging environmental conditions. Kraus & Naimer offers a range of additional AC load disconnect switches for insulated housings. This enables a complete installation from a single source.
Germany, Kirchzarten
... suitable for simple wall mounting with just 2 screws as well as for DIN rail mounting. Measurement ranges (including ± measurement ranges, asymmetric measurement ranges possible): 50 Pa .. 10 kPa Measurement accuracy (reference 0.3 Pa, for measurement ranges ≤±1.5 kPa): ± 1% of the set final value plus ± 0.5 Pa Power supply: 24 VAC/DC (reverse polarity protection), 15 .. 32 VDC (two-wire) or 24 VDC (galvanically isolated) Output signal: 0/2 .. 10 V or 0/4 .. 20 mA (switchable) Medium: Air, all non-aggressive and non-flammable gases Housing: Robust ABS housing with IP 67 for DIN rail or wall mounting...
Germany, Balingen-Ostdorf
...DC drive with bevel gear. Rotating spindle with spindle nut and push tube with integrated limit switches for use at fixed switch-on positions.
Germany, Hohen Neuendorf Ot Bergfelde
... supply 15 VDC / 10 mA Software features Definable setpoint range Configurable output range between 0-10V and 0/4-20mA Adjustable step size per key press Display blinking on limit value exceedance/undercut Digital inputs for key switches or external adjustment buttons Configurable code as adjustment protection for the setpoint Various operating options for setpoint adjustment Start behavior with last set value or default value...
Germany, Wermelskirchen
... speeds and 7 external speeds via inputs/outputs • Selection of rotation direction • Start signal input (optically isolated) • Rotation direction signal input (optically isolated) • Error signal output (optically isolated) • LED status indicator • Sealed cable openings for IP54 Nominal voltage: 24 V DC Protection class: IP20 DriveControl 54: IP54 Voltage range: 19 to 26 V DC (reverse polarity protection up to 30 V) Current consumption: up to 5 A without RollerDrive: 0.5 A Operating ambient temperature: 0 °C to 40 °C (32 °F to 104 °F) DriveControl 54: -28 °C to 40 °C (-18 °F to 104 °F)...
Germany, Friedrichshafen
...AM10: Position display for incremental encoders, SSI, Transsonar or EnDat 2.2 encoder. 7 1/2-digit device with a 14mm high 7-segment LED display. AM10: Large display range of 7 ½ digits, easily readable 14mm LED display, scalable measurement values (mm, inch, degrees, liters, ...) 2 relay outputs for limit switches, comparator or cam. 2 digital inputs for resetting, holding the display value, minimum and maximum display. Supply voltage: 24V DC Dimensions: 144x72x111mm...
...Control with reversing contactor unit Dimensions 180 x 180 x 75 mm • for motor power up to 2.2 kW • supply voltage 230V/N/PE or 3x400V/N/PE • control voltage operator 24V DC or 230V AC • mechanical limit switches Functions Operation in dead man's mode or self-holding Safety circuits for OPEN/CLOSE Optional accessories Operator Triple push button in the cover Main switch in the cover Output 110V DC for brake...
Germany, Villingen-Schwenningen
...-excitation period. Afterwards, the rectifier switches to the set holding voltage, which must not exceed the rated voltage of the electromagnet. Nominal input voltage: max. 415 V AC Max. output current ADC: Over-excitation: 4 - 12 A; Holding excitation: 2 - 9 A Over-excitation: yes Quick disconnection: external Standards: CE, ROHS, IP 00 Accessories (optional): DIN rail mounting, open circuit board, pluggable screw terminals...
... current • As option with analogue output • Broken wire detection • Protection against manipulation by sealable transparent cover over setting switches • Width: 52.5 mm Function:Residual current monitor, Type B Type of voltage:AC; DC Adjustable measuring ranges:0,01 ... 3 A Enclosure design:Installationsverteiler Width:52,5 mm Type:RN 5883...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play