Germany, Usingen
...Power Transformer Design: R50 Transformation Ratio u: 1 : 11.6 Power P: 25 VA POWER TRANSFORMER Power Ranges Transformation Ratio: highly variable Total Harmonic Distortion: up to 0.05% Linearity: up to 0.05 dB Frequency: 20 Hz – 200 kHz Voltage Withstand: 100 V – 5 kV DESIGN/CONNECTIONS • Ring core, • PCB/pluggable • free ends • MA, aluminum, plastic • Mounting cover APPLICATION AREAS • Electro-acoustic systems (ELA) with 100V technology • Component in switch-mode power supplies...
...We develop and manufacture HF transformers for you, ranging from very low power to capacities of 100 KVA. For larger constructions, we also design the mechanical mounting. To develop the transformers, it is necessary to receive specific information. We can draw on many years of experience with the following transformer variants: - Transformers for blocking converters - Transformers for resonant converters - Transformers for flux converters - Transformers for push-pull converters - Signal transformers - Isolation transformers - Ignition transformers...
Germany, Bünde
...Our transformer rental stations offer flexible and cost-effective solutions for temporary energy needs. They are quick and easy to install, making them ideal for construction sites, events, and emergency deployments. Our rental stations are fully equipped and provide a reliable power supply for the required duration.
Germany, Heiligenstadt I.ofr.
... according to VDE 0570-2-6 / EN 61558-2-6 with built-in safety transformer input-side matching taps mounting dimensions according to DIN 41308 finger-safe connections to screw terminals with self-releasing terminal clamps output-side circuitry: varistor, filter capacitor (105°C) and discharge resistor output-side components covered and finger-safe according to VDE 0106, Part 100 high-quality, tropical...
Germany, Leipzig
...XKBU816 are designed for use in networks with harmonic distortion. This includes high-precision transmission up to 20kHz, as well as the thermal load capacity of the current transformer.
Germany, Darmstadt
...Transformer oil catch basin with integrated and patented fire extinguishing system for electrical power and distribution transformers. Allows for a quick drainage of transformer oil into the self-extinguishing oil catch basin and a natural extinguishing of the flames.
Germany, Herne
... easily integrated into the oil circuit. There are four pump designs available for different applications: — Applications for power transformers — Inline pumps and angle pumps with radial impellers and inline pumps with screw-shaped impellers. — Applications for traction transformers — Pumps with radial impellers for traction transformers in rail vehicles.
Germany, Hilders
...The components of the ETD series (Economic Transformer Design) are an evolution of the EC series. They have been specifically designed for converters in switch-mode power supplies. Application: Switch-mode power supply converters for industrial power supply, 1400 W in push-pull operation with high-frequency litz wire and foil winding with static shielding between the windings with electrical shielding...
Germany, Alsfeld
...Type: ELT / ELTS Single-phase power transformer according to DIN/VDE 0532 separate windings Primary and secondary voltage see table Frequency: 50/60 Hz Insulation class: T40/B up to 5.0 kVA Insulation class: T40/F up to 6.3 kVA Protection class: IP00 (suitable up to IP23) Corrosion protection through resin impregnation Other voltages available on request.
Germany, Weisenheim Am Sand
...Transformer stations in concrete or steel: Compact stations up to 2.5 MVA, 33 kV, Walk-in stations up to 5 MVA, 33 kV, Transfer stations up to 33 kV, Inverter stations Transformer stations as transfer or transformer stations: - with medium voltage switchgear - with transformer - with low voltage distribution Variants: concrete, steel, or combined Custom dimensions For all applications: grid stations, PV parks, industry .... Worldwide delivery...
Matching products
Transformer Stations
Transformer Stations
Germany, Kriftel
Through many years of experience, we develop customized applications in close collaboration with our partners and customers. These are produced at our locations in Denmark, Latvia, and Thailand. Furthermore, we are represented throughout Europe and Asia with our offices and production facilities. With over 500 motivated Kohsel employees and our extensive experience, we can offer very high-qualit...
...Overhead and underground conductors in various designs and constructions for the construction of new lines, the repair of existing transmission grids, the connection of transformer substations, solar and wind power plants. Furthermore, the upgrading of existing lines with high-temperature conductors to increase transmission capacity.
Germany, Denkendorf
...Features Insulation class T 40 / B open design standing with separate windings foot angle creepage current safe transformer separation safe against hand back and finger contact according to UVV (VBG 4) corrosion protection through complete impregnation...
Germany, Reppenstedt
...LED Desktop Power Supply, Primary 100-240V / Secondary 12V DC, 36W, electronically regulated, connection cable with hollow plug (3.5mm x 1.35mm), Euro connection cable with power plug Housing color: black Input voltage: 90-264V AC Output voltage: 12V DC Connection: Plug-in power supply (input) / Hollow plug 3.5x1.35mm (output) Output current: 3A Dimensions: 105mm x 45mm x 30mm...
Germany, Neuenrade
...CSN® Neutral Earthing Resistors are used in power distribution systems for star point earthing of transformer or generator windings. According to the application (low or high ohmic neutral earthing type) pakkages made out of meander shaped stainless steel wire elements or CSN® Resistor Webs will be used as active material. Schniewindt has already supplied units for system voltages up to 380 kV...
...Energy-saving systems from Möller-Preussler not only save energy but also extend the lifespan of consumers. Available in various sizes/power ratings. Standardly available up to 4000A. High short-term and continuous load capacity due to solid power components in transformer technology, High efficiency (>99.0%), Low regulation deviation (calibrated 0.3%, otherwise 1.0%), No negative influence on...
...For the secure power supply of your systems, J. Schneider Elektrotechnik GmbH offers not only AC and DC UPS systems but also magnetic and transformer voltage stabilizers. DIN VDE 0550 single-phase, sine wave output Input: 230 or 400 V AC +15 &; -20 %, 50 Hz Protection class IP00 Output: 230 V (+1.5; -3 %)...
Germany, Oberrot
...We manufacture current transformers for measuring and monitoring currents while simultaneously providing electrical isolation between the measurement and power paths. We offer both through-hole current transformers and current transformers with integrated power paths. For 50 Hz applications, iron-based ring cores are typically used, while high-permeability or power ferrites are employed for higher frequencies. The insulation structure can be designed according to EN 60950 or EN 50178.
... Pt100 or pyrometer and the resistance is then corrected to the equivalent at e.g. 20 °C (adjustable) in the instrument. The application range is very wide such as the measurement of: — transformer motor coil windings — coils of all kind — cables and wires on the drum or as meter samples — switch and relay contacts — heating elements — fuses — connections and transitions at power rails and...
Germany, Dorsten
... you need a power supply package as a standalone solution for load testing or as a distribution transformer – we will find the right solution. We have a large inventory of containerized transformers for high and low voltage, which we utilize for the development and installation of customized power supply packages.
Germany, Mönsheim
... (plasma). The connection between the transformer and the generator is plug-in. The electrode head is connected to the transformer via a hose that contains the high voltage and compressed air lines. The electronics of the Arcospot are modular; the individual components in the generator are arranged in a plug-in format. The connections for signal inputs and outputs are designed with connectors...
Germany, Ehningen
...-effectiveness compared to other energy-saving devices available on the market. By saving a substantial part of the loss power, the investment is no longer the primary concern, as the eSaver finances itself through reduced operating costs. The transformer of the eSaver has a significantly smaller size compared to conventional transformers, allowing for high power outputs in a compact form. To keep the entire power supply network stable, the grid operators provide...
... can also be used. AGK ® manufactures custom-fit support blocks for you, whether you are building a new system or need to maintain an old transformer. The support blocks are delivered ready for installation, depending on which variant you require. Variants of Support Blocks The specific geometries of these temperature-resistant support blocks are as diverse as the various transformers. Therefore, AGK ® installs pins and elastic pads according to customer specifications. The vibration mechanical decoupling of the core and winding leads to reduced noise generation of the transformer. In the...
... fluid and oil purities — no matter how specific the conditions are. CJC® oil cleaning systems are renowned worldwide and are used in industry, shipping, mining, power plants, and wind energy systems. Our portfolio includes: • bypass filters • water separators • filters for heavy oil, quenching fluids, thermal oil • systems for the recovery of cooling lubricants • lubricating oil filters for gas engines / diesel engines • fuel cleaning systems, tank filters • dewatering systems for insulating oil and transformer pits • flushing filters...
... measuring receivers in the range of about 100 kHz to several MHz. The lower measurement threshold is rarely below 50 pC (pico Coulomb), even in shielded measuring locations due to disturbances. With the help of the TE filter, a partial discharge level of ≤ 10 pC can be achieved with the correct setup of the test field. This is necessary, for example, to operate test fields for transformers. The permissible partial discharge level depends on the power class of the transformer.
Germany, Marschacht
... energy-intensive pre-treatment. A generator supplies a maximum of 2 nozzle heads. Here too, special functional groups can be introduced onto the polymer surface using different process gases. Power: 600 W or 1000 W per nozzle Channels: 1-2 Process gas: Air, Oxygen, Argon, Nitrogen Non-potential: nearly Transformer: external...
Germany, Pförring
...Affordable power supply with adjustable voltage and current, featuring green illuminated displays. Perfect power supply for most tasks in workshop, school, laboratory, and hobby settings, for charging batteries, etc. This device is compliant with RiSU and has a built-in safety transformer according to DIN EN 61558-2-6:2009. Technical Specifications: Operating Voltage: 230 V~ Output Voltage: 0...
...which is directly applied to the strip material, ensures optimal heat dissipation. Due to low magnetostriction and excellent high-frequency properties, as well as the outstanding temperature resistance of the material, you achieve optimal conditions for a special design of your power transformer. Coating: epoxy orange (UL E345773) Losses @300mT, 100kHz, sin: <5W/core Weight: 395 gr...

The europages app is here!