France, Poissy
... Optical cell:Fused silica (Suprasil), l: approx. 230mm, heated approx. 45° Detection limit:0,1 ng/m³ corresponding to 0,5 pg Hg absolutely Sample volume:0,1 l to 10 l Sampling duration:9 sec … 15 min Measurement cycle time:3 … 99 min...
Italy, Verona
... magazines such as Wired Italia and among the solutions proposed by the famous influencer Cucina Botanica. EcoComunicazione, a supplier of SAES Getters S.p.a., has engaged HENRY & CO. for the calculation of the Life Cycle Assessment (LCA) and the circularity index of B!POD.
... sorting by defects are conducted. This guarantees 100 percent quality – with a cycle time of 3 seconds. Application area: Turned parts for automotive suppliers, special customer parts, general measurement tasks Tests: Hardness / crack testing, leak testing, etc. Sorting system: Automatic sorting of parts into 9 categories Cycle time: 3 sec.
... internal evaluation, the measurement curve and computed evaluation results are visualized on the color display and are also output at the external control interfaces. The processes in the controller are optimized by a powerful real-time operating system to achieve an extremely fast evaluation cycle: it typically takes just 15 ms to deliver the global OK or NOK evaluation result, which can then be...
...The Raytek Raynger 3i Plus handheld infrared thermometer is designed to meet process performance requirements in industrial applications, including highly demanding hot environments in primary and secondary metal processing, as well as petrochemical and power plant operations. The rugged pyrometer withstands a 1m (3.2ft) drop test and provides a longer operational cycle for up to 24 hours when...
Germany, München
... is covered. The sensors are calibrated to a common coordinate system and mounted on a movable gantry. Before measurement, the slabs are fixed in place. The scanners mounted on the gantry are guided over the measuring object, driven by an electric motor. The point cloud recorded by the four scanners is consolidated in a PC by means of the QuellTech image processing software which calculates the...
...Feeding screws with a vibrating bowl Preparation of the next screw during idle time Measuring the loosening torque with a torque sensor that can be integrated into the screwing cycle Loading the next workpiece to be screwed during idle time using a loading carousel Removable precision fixture ensuring accurate positioning and multi-type workpiece management Tablet user interface allowing configuration of different screwing positions by workpiece types Integrable into an assembly line...
Germany, Kötz
...Semi-automatic testing device for pins Diameter: 10 – 35 mm, Length: 15 – 70 mm Dimension check contour: - Outer diameter, roundness, conicity (Measurement accuracy ± 0.0005 mm) - Length measurement (Measurement accuracy ± 0.01 mm) - Noise generation: The noise level can be tested by regulating the throughput and increasing the pressure. - Multiple sorting by dimension classes (2 ranges + scrap) Cycle times depending on pin size: 1.5 – 2.5 sec/piece...
...Fully automatic end-of-line tester for checking the functionality of oil pumps under specific operating conditions Measurement principle: Test specimen is integrated into the oil circuit Application of parameters (pressure, temperature, speed) Collection of measurement data (flow rate, speed, torque…) Properties: 100% testing High testing throughput, short cycle time...
...The RSA Series is designed to identify suspension springs with the appropriate load class based on an individual payload measurement result. The system receives the measurement results from the upstream system. The system is available as a single or double cycle version (depending on the required throughput). Simple linear axes, single- or twin-robot systems are used as handling systems. Since...
Italy, Legnano
... 2100A for 1 Phase unit. Voltage Range 480V, 600V and 690V. CE-EMC Listed, EAC Listed, cUL 508 Listed up to 700A, UL listed from 800A to 2100A. Universal Input: The std analog inputs 4:20mA and 0:10V and SSR Configurable via Software. All types of firing mode Half Cycle, Single Cycle, Burst Firing, Delayed Triggering Phase Angle and Soft Start. OLED display on front Unit: This display give better operator interface and delivers use-friendly intuitive messages. Universal Control Mode: Current, Voltage, Power, Open Loop.High precision measurement (True RMS Value for V,I and VxI) ≤1% ...
...Cooling Electrode: indirectly water-cooled Cooling Nozzle: indirectly water-cooled Weldable Thickness: 0.05 to 1mm Max. Current Capacity: 20 A Duty Cycle: 100 % Plasma Gas: Argon Shielding Gas: Argon, Argon/Hydrogen Application Micro Plasma Welding: - Electrical Industry - Aerospace - Nuclear Technology - Measurement and Instrumentation - Apparatus Construction - Screen Manufacturing - Dental Laboratories - etc.
...Removal of determined locking ring class (double removal) with control measurement and transfer to assembly station Locking ring assembly and testing (cycle time approx. 30 sec.)...
France, Narbonne
...ointment, body lotion, etc.), - Chemical products (detergents, solvents, household cleaners, etc.). Depending on the type of product, either electromagnetic or mass flow measurement is used for dosing. With the system optimized for the production of small to medium production volumes, depending on the product and container, cycle rates of up to 600 bottles/hour can be achieved. The K-Net model is compatible with CDA's semi-automatic and fully automatic labeling machines.
France, La Mulatière
...Ultrasonic Level Transmitter ULG-(X) Precision: 0.2% over measurement range Output load: 0~500 Ω Pressure: 0.1 MPa Detection cycle: 1.5 seconds Sonic beam angle: 8° (3db) Power supply: 24VDC Output signal: 4 – 20 mA...
United Kingdom, Redditch
... leak testing cycle on the market. Automotive, domestic appliances, medical, aeronautic, defense, fluid and electrical components, food and cosmetic packaging Flow measurement in direct or indirect testing Continuous measuring mode Wide flow measurement range USA, S.I. and customer units Measurement in standard or customised conditions Recalculated flow at the nominal pressure Measurement element fully integrated into one module 128 programs Mechanical or electronic regulator from vacuum to 10 bar Weight:7 Kg Dimensions:(WxHxD) 540x160x380 mm Operating:+ 5°C at + 45°C Storage:0°C at + 60°C...
Switzerland, Rossens
...easy-to-read, customizable readout displays volts, amps, power and power factor Measurement: Continuous or cycle-by-cycle Bandwidth: DC up to 80 kHz Input Power: Accepts 85/264 Vrms, 60/50 Hz power at 20 VA max Auto Ranging: Automatically scales instrument for most accurate range Isolation: 1000 Vrms to earth, 750 Vrms line-to-line Average: Displays running average of amps, volts and watts Peak Hold: Stores the highest value read. Values can include amps, watts and volts in any combination Calibration Certificate: NIST Traceable Rack Mounting: 19” (482.6 mm) with handles...
... Meets CE, UL, ISO EN and CSA safety requirements Automatic test countdown based on time or radiant exposure VibraSonic TM Humidification System Specimen Holders available to accommodate many sample types Calibrated xenon reference lamp Water purity indicator Dual Black Panel Temperature (BPT) and Black Standard Temperature (BST) Measurement/Control including uninsulated BPT and BST sensors...
Germany, Wartenberg
... adapt to different pressure conditions and enables the user to correlate their paint viscosity control with the current printing results. The key features of the inline sensor are: - Integration into the color cycle via a bypass - Use of high-quality materials (stainless steel) - Maintenance-free operation - No rotating parts and no mechanical seals - Continuous measurements, no time-dependent measurement points - Usable for water-based and solvent-based paints - Viscosity range from 1 to 1,000 centipoise...
Germany, Duisburg
... a tested and ready to use measuring system which is very reliable and easy to maintain. The system is suitable for a wide range of water analysis measurement tasks. — Complete measuring system – ready to use and easy maintenance — High quality and precise gold electrodes for usage in water analysis — Membrane-free sensor for a wide application range Measured value::temperature Measured entity::chlorine; water Configuration::portable Measuring range Cl2::0.03...20 mg/l Measuring range ClO2::0.05...5 mg/l Measuring range O3::0.05...5 mg/l Temperature::Max. +50°C / +122°F...
France, La Fleche
... each stage – Repetition of the measurement Validation process: – Measurement of two cycles at full load – Reading and interpretation of the obtained values – Customization of the protocol possible COMMITMENTS Issuance of a report within 30 days summarizing the requirements of the requester Comparison of results against acceptability criteria Optimization recommendations: – Regulation parameters – Reconstruction of scales – Loading plan...
Germany, Reilingen
...Methods and equipment for measuring the cylinder pressure in piston machines: p-V 1.0 and PicopV 1.0 user`s software for determination of p-V-diagrams with DiaW - Diagram for Windows. p-V forms a p-V diagram from a PC file containing measured values of the pressure and information about the rotary position of the crankshaft, and calculates the work delivered or consumed by the working cycle...
Germany, Groß-Zimmern
...Manual Insertion and Removal Automatic Program Sequence Cycle Time/Rim approx. 20 sec. Evaluation by integrated industrial PC. The color monitor records the progression of diameter and height variation over the total circumference of the rim, marked in green or red to indicate whether it is within or outside the permissible tolerance. Measurement Data Acquisition and Evaluation: With...
Switzerland, Dierikon
... conductor:0.012 in. – 0.08 in. Conductor cross section:AWG44 – 16 Minimum diameter of inner conductors:0.002 in. Resolution diameter:0.0004 in. Maximum pull-off length:1.6 in. Increment of pull-off length:0.0004 in. Maximum stripping steps:9 Cycle time:6 seconds Production rate:Approx. 600 pcs/h Database capacity:1000 programs Gripper force:Adjustable in 10 increments Electrical connection:1 × 100 – 240 V | 50/60 Hz | 120 VA Pneumatic connection:73 – 102 psi Noise emitted:Type < 50 dB (A) Dimensions (W × H × D):5.5 × 9.6 × 22.4 in. Weight:20.3 lbs RoHS:Complies with the Restriction of RoHS...
Switzerland, Reinach Bl
...The integrated application package "differential pressure" enables easy and quick commissioning of differential pressure applications. Measuring Principle: Display Function: Screen; Cycle power supply; Transmitter functionality; Barrier; Signal isolation Certification: ATEX II (1) GD [Ex ia] 4C; CSA AIS; NI/I/2 ABCDEFG/T4; FM AIS; NI/I/2 ABCDEFG/T4 Input: 2 universal (U, I, R, RTD, TC) Output: 2...
Germany, Heilbad Heiligenstadt
...The Frost-Thaw Cycle Testing Chamber FTT 120 is used for conducting frost-thaw cycle tests.
... product lifecycle in fast motion and can provide insights into potential failures. We conduct mechanical-dynamic environmental tests (vibration, shock, impact, drop, etc.), climate tests (e.g., 2-chamber temperature shock procedures, humidity storage), IP protection class tests, vacuum tests, tests for resistance to chemical influences, as well as endurance tests and life-cycle tests. Feel free to ask us about the various testing options.
Germany, Chemnitz
... the NB series. For all the necessary manufacturing operations Starrag provides the benchmark Efficient roughing for Blisks machined from solid, adaptive machining for friction welded Blisks, high dynamic finishing of the airfoils in point contact. Shortest cycle times and zero scrap rate production are achievable on the Starrag NB series. The NB series is based on the very successful Starrag LX...
Poland, Bydgoszcz
...Static and dynamic imbalance display, Autotest and selfcalibration, Data transfer and communication with master station, CSV file data creation Sophisticated remote diagnostic and support software . Max. wheel weight:50 kg Max. wheel diamater:700 mm Max. hub clamping diamater:84 mm Measuring cycle time:6-10 sec...
France, La Wantzenau
... / outputs 4 * 24V PNP inputs / outputs for options (currently without function). Transmission width 9 to 26 data bits. See also chapter « 6.2.3. DIP Switch S1 : Switch 5 – 7 (Number of SSI data bits) ». Cycle time synchronous to the SSI master reading: approx. 80μsec – 150μsec depending on the set master clock frequency or externally by clock reaching at slave output 1 or 2 or by the adjacent clock in listening mode at the master input (DIP switch S1: Switch 1 + 2).
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store