Portugal, Maia
...Advanced combustion control platform and all boiler components, ensuring combustion efficiencies of over 90%. By using frequency inverters, we ensure very low electrical consumption/steam produced ratios. The use of a 15” touch panel allows easy viewing and operation of the entire boiler. By providing an internet connection, the system is prepared for remote assistance.
Italy, Pergola
...Even at home, the FIAMMA model brings class and elegance. Carefully crafted and exclusive design: with rounded glass doors that make it unique and distinctive. The openings of the combustion chamber also abandon the classic shape to take on a new one in pure "flame" style. An oven that pleasantly surprises with the precision of its details, from the handles to the hinges, to the control panel.
... from the WiT-es and WiPr-es sensors, processing it, and automatically adjusting the relay outputs based on defined parameters, while displaying sensor information on the screen. By intelligently switching its operation based on the temperature and pressure data received from the WiT-es and WiPr-es sensors, Wi-CoRe ensures optimal regulation and minimizes manual intervention in control systems.
Germany, Hohen Neuendorf Ot Bergfelde
ICS Schneider Messtechnik GmbH has developed into a powerful supplier and manufacturer with a wide range of products through constant growth and adaptation to the market. The company's service offerings include consulting, development, production, sales, and service. Our product range includes measuring devices, converters, signal converters, energy meters, pressure and temperature measurement te...
France, Poissy
...Ecodesigned, ultracompact, smart & connected instrument, the MIR 9000e is your next tool to measure combustion exhaust gas from boiler or gas from different industrial furnaces and process applications. It offers superior metrological performances for the simultaneous multigas measurement of NOx, SO2, CO, O2, residual H2O, CO2, CH4 and N2O (greenhouse gases). • ultralow power consumption • no...
Germany, Heinsberg
...FS200 FOG AND COMBUSTION GAS SIMULATOR Ideal for testing tightness and locating leaks in pipelines or flat roof constructions. This professional fog and combustion gas simulator, made in Germany with high quality, is the most compact and lightweight device in its power class. Thanks to its intelligent slim design, constructed from lightweight yet sturdy aluminum, the FS200 can be easily carried...
...The PROTHERM 470 controller is designed to monitor, control, record, and archive combustion processes running in a furnace or simultaneously in multiple chambers. This powerful controller is suitable for various types of batch and continuous operations and can be installated on new, retrofit, or refurbished equipment. The fully configurable I/O channels can be used with oxygen sensors or any...
...* 4 motors, drum, airflow, mixer and cooler motors. You can roast new batch while you are cooling previous batch. * Premix burner with flame control. Our burners mix the air and gas before blowing into the burner head for efficient combustion to reduce gas consumption. And you can adjust the flame power which is very important for roasting process as you need it to control chemical reactions...
United Kingdom, Cannock
... boiler allows for excellent combustion, stable temperatures and reduced short-cycling. Dual stage burner accurately matches fluctuating heat requirements and achieves lower emissions at part-load operation. Integrated 3-way valve ensures operating temperature is quickly achieved, maintains tight temperature control and reduces short-cycling. Able to communicate with building management systems and...
France, Perriers-Sur-Andelle
... steam tubes ø 27 mm with cross tube ø 27 mm, metal structure with cylindrical combustion chamber made of AISI 309S refractory steel (without masonry parts) - DIGITAL control panel with 99 programs, positionable on the left or right during installation - External cladding: stainless steel - Cooking slabs: mixture of gravel and refractory cement with metal reinforcement - Steam: equipped with independent steam devices positioned under the chambers and steam evacuation ducts.
Greece, Thessaloniki
... from the chimney, as well as the particulate emissions into the atmosphere. Its innovative design offers the possibility of control of up to four room thermostats, adjusting the temperature in each space to the level the user desires. Moreover, the automatic functioning mode “pyrolysis cleaning” helps eliminating tar and deposits from the boiler wall, facilitating thus its cleaning. ...
...Bosch combustion gas heat exchanger for hot water boilers - The exhaust gas heat exchanger is part of the standard equipment for environmentally friendly boiler operation with optimal energy consumption. — Effective heat recovery and reduction of losses in the gases — Maximum efficiency using condensation technologies — Fuel savings of up to 7%, and even up to 15% using condensation technologies — Intelligent control for a long lifespan while maintaining a high level of efficiency — Compact integration into the boiler or standalone version for easy upgrades...
Germany, Weidenbach
... derived from oxygen, natural gas, biogas, sewage gas, special gases, as well as diesel and other liquid fuels - Compliant with international standards and directives - Available in single, double, or triple versions for use with one, two, or three engines with completely separate combustion gas paths - The ACS (APROVIS Controlling System) is customized for each project and delivered in the desired language...
... test their components in fast-forward mode using the pressure change test stand from Poppe + Potthoff Maschinenbau at an early stage of development. The component, for example, a... Frequency: 0.2 Hz Medium temperature heating circuit: +20° C to +140° C / Heating power at 12 KW Medium temperature cooling circuit: +20° C to -40° C / Cooling power at 5 KW down to -30° C and at 2 KW down to -40° C Test medium: Water - glycol mixture / pure glycol Ambient temperatures: -40° C to 140° C Flow rate control: 3 to 30 l/min dynamic pressure change: 0.2 to 10 bar...
... for optimizing control units (Engine Control Unit) - Turbocharger speed - Oil dilution measurement and oil consumption measurement - etc. Of course, we provide the corresponding test protocols for all test and test bench runs.
Germany, Freiberg Am Neckar
... - Wood pellets - Paper pellets - Cocoa shells - Coffee grounds - Olive pits - Rice husks - Cotton seed hulls - Bagasse can be optimally burned in our biomass combustion systems. With effective accessories for control elements and auxiliary units, solutions are also offered for unusual situations.
... of power requirements in single or multi-stage operation. The NOXmatic flare is manufactured entirely from stainless steel and equipped with high quality components (i.e., ATEX certified flame arresters, DVGW certified automatic and manual valves...). All control and monitoring functions are achieved with an individual programmable controller, which also governs the signal transfer with the main controller. NOXmatic flares can be delivered worldwide with a capacity from 100kW to 20MW.
...Advantages of the UNIFLAM PRESTIGE fireplace insert Air supply from the outside The insert is equipped with a direct supply of air from the outside to the furnace. Air can be supplied through a 100mm diameter flex pipe or a 150x50mm rectangular duct The damper allows you to adjust the chimney draft and control the rate of combustion. The damper knob is located in the upper part of the insert...
Spain, Manlleu-Barcelona
...MI - Portable Diesel Heater for Open Spaces from 38 to 111 kW - The portable heater powered by diesel is used in open or properly ventilated spaces, and its main advantages are its speed and complete mobility. The hot air it generates contains combustion gases, and it should only be used in open or properly ventilated areas. Construction Details: - Integrated diesel burner - Electronic control...
...%): 450 : 1 (2.2 mrad) Measurement points per line scanner: 1024 per line (2048 for CS212) Ambient temperature: -40...45 °C (no direct sunlight) Ambient temperature - position sensor: -25 ...230 ºC Alarm zones: 48 software, 3 hardware (PC independent) Kiln speed: Up to 10 rpm Tire ring management (LRM): Supports up to 6 tire rings Fan control: Up to 16 fans per module (48 total) Communication: Ethernet TCP/IP Analog outputs: 3 x 4 – 20 mA Alarm output: Relay, contacts: 30 V, 1 A Power supply: 24 VDC ± 25 %, 1 A...
Italy, Grugliasco
...The RCB grinder is a machine designed for processing the groove area of valves for internal combustion engines. The flexibility of the RCB allows for the machining of engine valves with different stem sizes and groove types, featuring a very quick changeover time. The grinding wheel used is Ø 610 mm. On the right side of the machine, there is a CNC control unit. For the safety of personnel, the...
...Optional combustion probe with a flexible rod length of 220mm and a hose length of 2 meters. Compatible with the analyzers: KANE251, KANE255, KANE450, KANE453, KANE455, KANE501, KANE504. Allows for combustion analysis in areas where it is difficult to insert a standard rigid probe, such as in flue gas ducts.
Germany, Bochum
...Regulation stations are used to capture fuel mass flows and to individually and optimally adjust the operating parameters of the combustion system. They provide the option for both overall and individual regulation. The design and execution of the measurement and regulation stations are tailored to the requirements of the system and customer preferences. Advantages - Compact design, pre-tested...
Germany, Reilingen
...• Automatic gravimetric determination of the specific fuel consumption of internal combustion engines. • Automatic documentation of measurements. The MP-Computer offers several options for this: 1. Output to "DiaW-Diagram for Windows" on an IBM-compatible standard PC. 2. Protocol printing in text form during measurement (manual and time-controlled). 3. Measurement value output via analog voltages. • additional customer-specific...
Germany, Heiligenhaus
... control unit required by the flame signal amplifier. No adjustments are necessary during commissioning or maintenance. The KLC 20 only evaluates the flickering of the flame being monitored. An optional device version with interference frequency suppression is available. Equal light radiation and any constant frequencies do not lead to permanent flame detection. The LED display serves as an optical interface, allowing for the reading of various relevant operating parameters.
Germany, Wimsheim
...High precision vacuum pressure control valve for exhaust emission analyzer. Temperature proof up to 180 °C and acid resistant against exhaust of combustion engines. Constant vacuum pressure even at high pressure peaks at inlet (for example generated by turbo combustion engines) Outlet pressure: 0.9 at (0.1 bar below atmosphere) Outlet pressure deviation: approx. 70 mbar Inlet pressure: max. 3 bar (4 at) Different outlet pressure ranges and other flange versions can be offered.
United Kingdom, LINCOLN
... expensive. Despite its environmental challenges due to high sulfur content, Mazut remains a crucial energy source for power plants and industrial facilities in many parts of the world. Its availability and affordability make it a reliable choice for meeting large-scale energy needs, while ongoing advancements in refining and emissions control technologies aim to mitigate its environmental impact.
Türkiye, Istanbul
...Corrosion resistant, light Aluminium heat exchanger Efficiency up to %108,5 Modulation ratio 71 12 different capacities (830 kW to 3250 kW) Cascade system with 16 boilers Workıng pressure 6 bar High combustion performance with low exhaust emission Different zone controls with Siemens control panel Compability with Open Therm ve BUS comunication systems Easy to use and maintenance...
... aggressive environments. These meters use vibrating fork technology for reliable direct-insertion measurement. HFVMs provide Heavy Fuel Oil (HFO)/Marine Gas Oil (MGO) combustion control, and oil-fired heater and boiler control.
... analyzer, very lightweight and compact, eco-designed and cost-effective, with ultra-low energy consumption Compatible with all types of drying technologies (chiller, permeation, dilution…) High precision, excellent stability, economical, easy and low maintenance Insensitive to temperature variations in the range of +5° to +40°C (no air conditioning required) Intelligent analyzer including AMS control features: sampling control, calibration gas injection, external pump control, system alarm display…...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play