Türkiye, Bursa
...]:28x0,10 mm INSULATION MATERIAL AND DIAMETER [mm]:P.E.1,50mm ±0,05 COPPER SHIELDING:100% COPPER SPIRAL SHIELDING OUTER SHEATH AND DIAMETER [mm ]:LSZH 6,3 mm APPROXIMATE WEIGHT [kg/100m]:4,5 kg/100m CONDUCTOR RESISTANCE [Ω/km]:<86 Ω/km SHIELDING RESISTANCE [ Ω/km]:< 39 MΩ/km INSULATION RESISTANCE [MΩxkm]:>1000 MΩxkm CAPACITANCE (pF/m) core/core core/screen [pF/m]:68 pF/m 130 pF/m WORKING TEMPARATURE:-20°C to +70°C BENDING RADIUS:8x outer diameter...
France, Villepinte
... insulation according to NF C 93-529 standard Identification of conductors Assembly in pairs Armored with 2 steel tapes arranged in a helix Copper drain under tinned shield Ø 0.45mm Outer sheath: gray PVC Ø 9.8mm Cable weight: 147 kg/km Maximum operating voltage: 300 V Maximum permissible current: 3A / mm² Maximum core resistance: < or = 96 Ohm/km Minimum insulation resistance: > or = 1500 MOhm/km Mutual capacitance: < or = 80 nF/km at 800 Hz Pair/pair capacitance imbalance: < 300pF/500m Impedance: +/-100 Ohm at 1 MHz Attenuation at 2 MHz: 4.2dB/100m Ref: SYT2.2.20G...
France, Montmirail
...Axon' has developed picocoax® a complete range of miniature coaxial cables and harnesses for applications where a large number of signals have to be transmitted with no interference. They can be used for measurement equipment and medical devices. Picocoax miniature coaxial cables offer a good compromise between small diameter (for example 0.20 mm) and capacitance of 50 to 100 pF/m. Picocoax®...
Germany, Köln
... V (dc) (4) remote zero input:2-wire, current loop High level:+21 ... +27 V(dc) / ≤8 mA Low level:≤2 High level (pulse >1s):auto zero adjust Degree of protection:IP 30 CE conformity:EN 61000‑6‑2, EN 61000-6-3, EN 61010, 61326-1 & RoHS ETL certification:UL 61010‑1, CSA 22.2 No.61010‑1 Electrical connection:D-Sub, 9-pin, male Without remote zero:two-wire cable plus shielding, twisted With remote...
Germany, Asslar
... relatively high-impedance input resistances, low-capacitance supply lines are required to avoid unwanted drop in height. 1- to 8-core constructions, each of which has low-capacitance PE insulation with individual core screening, meet these requirements. Core cross-sections of 0.08 mm² and 0.14 mm² are used. Type:NFP 1402 CA Product number:1069 Purpose of use:Audio cable Jacket material:PVC Diameter (mm):6,0 x 2,65 Country of origin:Germany...
France, Toulouse Cedex
...31.4 1000MHz: 36.4 capacitance (PF/M): - velocity ratio: - operating temperature range: - length: 100m (on reel) Extras legend AL = aluminium CU = copper wire CU SN = tinned copper wire CU AG = silver-plated copper wire CW = copper plated steel LAP = aluminium / polyester film PEE = polyethylene PVC = polyvinylchloride PVC II = polyvinylchloride (non-migrating)...
France, Canejan
...Fire-resistant cable with aluminum foil shielding and red PVC sheath that does not propagate flame, designed for high-speed digital connections between security and fire alarm equipment. Operating temperature: -30°C to +80°C Characteristic impedance: 100 ± 20 ohms Mutual capacitance: 55 ± 5 pF/m Maximum linear attenuation at 2 MHz: 3.5 dB/100m Flame non-propagating category C2 according to NF C...
...S/P-DIF Digital Adapter Cable 75 Ohm, 1x RCA to 1x BNC Audio-IN Adapter Digital Cable 75 Ohm Coaxial 1x RCA Connector <> 1x BNC Connector - S/P-DIF cable with a data rate of 1.5 Gb/s - Impedance 75 Ohm +/- 1% - Solid OFC copper inner conductor 1 x 0.80 mm² - Capacitance 53 pF (conductor/shield) - HICON connectors 24k gold-plated, Teflon insulated - Black/blue fabric for good aesthetics and...
Germany, Betzigau
... • Version with pipe and cable extensions • Pressure-resistant versions up to 25 bar • Temperature solutions from -40 °C to +180 °C • Food-safe design Approvals: ATEX, IEC-Ex, TR-CU, CCC-Ex, dust explosion protected Process temperature range: -40°C to +120°C Pressure range: -1 bar to +25 bar Sensitivity: DK value >1.6 - adjustable in 4 levels...
ufs.country_names.RU, Moscow
...robust and user-friendly High voltage regime:100x100x12 um Low voltage regime:3x3x3 um Scanner type:Metrological piezotube XYZ scanner with sensors Sensors type:XYZ – ultrafast capacitance sensors Low noise XY sensor:<0.3 nm Metrological Z sensor:<0.03 nm Metrological XY sensor:<0.1% Sensors linearity Metrological Z sensor:<0.1% Resolution:XY - 0.3 nm, Z - 0.03 nm Linearity:XY - <0.1%, Z - <0.1...
France, Chambray Les Tours Cedex
... connection (G1 1/2 as standard), A rigid or cable electrode, in contact with the product, Electronics mounted in the probe head or remote in a waterproof housing with connection via coaxial cable. Operating Principle The probe, the tank, and the measured product form a capacitor whose capacitance is a function of the filling level. Thus, variations in the height of the product are translated into variations in capacitance. This variation in capacitance is converted into a "binary" signal for level detection and into an analog signal.
Switzerland, Reinach Bl
... the Oil & Gas, chemical, and petrochemical industries. Measuring Principle: Guided radar Characteristic / Application: High-quality multiparameter device (capacitance and guided radar); Rod probe, Interface measurement: Liquid/liquid interfaces also with emulsion layers; Simultaneous measurement of interfaces and levels Supply / Communication: 2 wires (HART / PROFIBUS PA / FOUNDATION Fieldbus); 4...
Germany, Düsseldorf
...), variations in capacitance occur, which are then measured and processed. The output voltage follows the function U ~ g * sin(α). Here, the angle α is the tilt angle of the sensor measured relative to the vector g. These sensors measure accurately, have a long lifespan, and are very robust. The measurement axes operate independently of each other. Interface: PROFINET Material: Aluminum AIMgSi 1, Stainless Steel 1.4404 Housing Diameter: 65mm, 90mm Profile: Standard, PROFINET Electrical Connection: M12 Connector, Cable Outlet...
Türkiye, Umraniye/istanbul
...These low capacitance double screened cables are mostly used in frequency-controlled motor supplies where electromagnetic interference occurs. They are also used in air conditioning systems, power plants, automotive industry, buildings, industrial pumps, heavy industry. They can be used in dry, moist, acidic and oily places with medium mechanical stress. In the event of a fire, thanks to their HFFR compound, they do not catch fire easily and the fire goes off itself. These cables have low smoke density and they do not produce poisonous and corrosive gases during fire.
Belgium, Bruxelles
...Standard analog microphone cable ▪ Low capacitance, greater distance ▪ 7 colors...
Germany, Weißenburg
...Franz Raab GmbH produces single and multi-core or paired microphone cables with various types of shielding. The selection of suitable insulation materials ensures excellent properties in terms of transmission quality. This includes low capacitance, optimal attenuation values, and long transmission ranges. The still-current trademark MY® for our proven standard cable products was registered with the patent office in 1964.
... 24V DC supply) • Supply and measurement voltage galvanically isolated • Safety circuit: In case of power supply failure or transformer failure, the filling or emptying process is stopped. Measurement Range KΩ (Center Position) Conductivity µS max. Electrode Current ≈ µA Cable Capacitance nF (Center Position) Cable Length m (Center Position) Standard -110 (50) 10 < 200 9-120 (60) 25-300 (150...
Germany, Weil Am Rhein
... of electrostatic charges. Product features: - Capacitive ground monitoring device, suitable for installation in explosive zones 1 + 2 (21 + 22) - Supply voltage: 100 – 240 VAC, 47 – 63 Hz, automatic network detection - Housing material: Aluminum casting, Ex-approved housing - Housing weight: 10 kg - Housing entries: 4 openings for M20 cable glands - Housing protection class: IP66 - Housing...
Germany, Berg Bei Neumarkt
... implement a requirement or even just an idea. We can analyze various solution approaches and also create initial test samples. No project is too complex for us - test us! We have several testing computers in our company to check the most diverse requirements. We can verify wiring in the low voltage range up to 48V for functionality, as well as conduct insulation or short circuit tests in the high voltage range up to 1500V DC. Through capacitance measurement, we can check unilaterally applied shields or twisted wires.
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play