...decentralized signal acquisition, robust and precise. µCAN-Transmitter Series: Protection class IP 67, space-saving integration directly in the measurement line of temperature and strain gauge sensors. µCAN-OEM Series: CAN bus connection directly in the sensor housing, equipped with a high-speed CAN interface that supports CAN 2.0A and CAN 2.0B. Analog Acquisition: Temperature, pressure, current, voltage Digital Acquisition: Input and output Bus System: CAN, CAN FD Protocols: CANopen, CANopen FD, J1939...
Belgium, Chaumont-Gistoux
...New for 2016: Microprecision Electronics SA expands the capabilities of its MP700 series of waterproof limit switches in response to the industry's trend of connecting position switches as a detection device for industrial bus systems. To facilitate interfacing with a distribution box, an M12 connector is integrated directly into the switch housing. This allows for a simpler and more flexible...
Germany, Hamburg
...II, III Div. 1) 20 mm LCD display, 14 segments, 7 digits, weighing value with status data, backlit Stainless steel housing, IP69K Scale connection for analog Ex platforms, such as Combics Ex, IU Ex, IF Ex or Ex load cells. Optionally, also digital IS scales (xBPI) Internal "alibi" memory RS232 \\ 485 \\ 422 serial interface Various power supply options available, including battery pack Profibus DP field bus and 4 ... 20 mA interface Display: LCD display Other features: made of stainless steel...
...revolutions no., steps per rev., rotation direction and preset no. The diagnostic function signals possible parameter, position or temperature errors as well as the battery alarm – the data memory is anyway ensured for a long period (30 years). The baud rate and node selection can be easily set by LSS protocol or by means of dip-switches. MEM40-Bus encoders avail on 3 signalling LEDs for supply...
Germany, Buchenbach
...Compact and powerful servomotor for automated positioning activities. Easy installation, no additional parts required. Hollow stainless steel shaft, reinforced fiberglass plastic housing. 24 V DC brushless motor with long operating life. Robust absolute encoder, magnetic detection. Two-line LCD display for setpoint and actual value, along with control buttons. Operator guidance via two LEDs. Integrated RS485 or CANopen interface. Built-in positioning controller. M8 + M12 connectors.
...)  Product status:Standard product  Field bus interfaces:EtherCAT / FSoE  Type of connection:female plug with PUSH IN spring connection  Status indication:LEDs allocated to the point of termination  Housing material:Aluminium frame, plastic housing  Dimensions (W x H x D):25 x 120 x 90 mm  IP-Protection Class:IP 20  Supply voltage:24 (-20% / +25%) VDC  Operating temperature:0 ... +55  Immunity:Zone B according to EN 61131-8  Certifications:CE, UL ...
Germany, Schwabach
...• Gateway for easy integration of BMR inverters with higher-level machine controls • Supports nearly all industrial and field bus systems • Designed for applications in the Industry 4.0 sector • Interface for a modular, intelligent, and compact system solution • Available in an SSE form factor in a narrow, robust metal housing • Modular design of the SFU Communicator (plug-in modules for various...
Germany, Mülheim
...For quick assembly, easy parameterization, and secure protection of the interface modules, we provide the right accessories. From the spring-loaded terminal and resistance module to the programming adapter and power bus, as well as the IP67 protective housing: each item is precisely tailored to the interface modules of the IM, IME, and IMC series, making the installation and commissioning of your application easier.
Germany, Krefeld
...When space-saving mechanical integration, along with the specific arrangement of connections and high current-carrying capacity, are the top design criteria, our custom film capacitor modules are the ideal solution. An almost limitless variety of designs for the integrated bus bar and plastic housing allows for direct screw connections with the IGBTs, which not only results in very low ESR and ESL values but also makes traditional snubber capacitors unnecessary. These products also meet all compliance requirements.
Türkiye, Istanbul
...Busbar System - Quick and Easy AssemblyE-Line KX Series Compact Busbar Systems are used in horizontal and vertical energy distribution and transmission in Bolt-on (supply from the junctures) and Plug-in (from window points on the busbar housing and the junctures) types. In addition, they can be utilized at segments of factories and buildings where electrical outlets are not required for transmission purposes only. With its special design,a minimum voltage drop occurs.
...Telco Amplifier for LT/LR up to 30 speaker channels Range: LT/LR 100 = 18m, 110 = 40m, 120 = 70m PAB 10 Range: LT/LR 100 = 12m, 110 = 27m, 120 = 47m PAB 20/30 Any number of light beams (up to 30 lines) possible Modern housing technology for 35mm DIN rail Each amplifier can be connected via BRC connectors - like a BUS system All connections are plug-in - resulting in short installation times Common or separate switching outputs Test input Alarm output Time delay 0 - 10 sec. LT/LR LED control...
Austria, Villach
...IP65 - built for harsh environments. - Extruded aluminum housing. Vibration and shock resistant. Pressure relief valve to prevent condensation. Electronics sealed inside. "Auto Wake-Up" of the battery. - BMS is activated by predefined voltage pulses from the ATLAS-300. Automatic restart of charging. - After a defined number of days / given voltage level at the battery terminals. Charging characteristics as desired. - Parameterization via IR interface. Additional features (optional): - CAN bus - LCD display (IP68 socket) - Immobilizer (IP68 outlet with control cable)...
Germany, Hohen Neuendorf Ot Bergfelde
...liquid sound velocity, and temperature. The outputs and bus communication allow for reading all primary process information either immediately (10 ms update rate) or regularly, depending on the needs of the system.
... levels. Advantages - Compatible with all JMei transmitters. - Numerous available buses: CANopen, Ethernet/IP, Profibus, Profinet, RS232/485, USB. - High certified safety performance level (PLd or PLe). - Compact design. - High protection rating: IP66 housing and connectors. - Intuitive control and diagnostic interface on the cover. - Multi-voltage: 4.5 to 36VDC. - Multi-frequency: ranges from 434MHz to 2.4GHz. - Relay outputs: 1 safety relay with double contacts + 1 function relay.
Germany, Crailsheim
...Manufacturing of bus module systems for silo level monitoring and filling systems Bus module system for silo level monitoring, filling systems,... · Load cell interface LCI-M · Housing 85mm x 65mm x 25mm · DIN rail mounting · Load cell connection 1 · Connection type terminal technology, cold welded · Sensitivity 1mV/V-3.6mV/V · Maximum number of measurements 4000/s · Power supply via power...
Germany, Kirchzarten
... spindle using the hollow shaft without the need for an additional coupling. The optional rotatable attachment housing allows you to attach the direct drives to the machine in any position, no angle plugs are required. Nominal torque / nominal rated speed:0,8 .. 3 Nm / 200 .. 50 rpm Positioning range:986 .. 4026 rotations Protection class:IP 50 or IP 65 Design:Horizontal construction, Nema 17...
...Ideal for protecting I/O interfaces, bus voltages, and other circuits from sensitive electronic equipment against overvoltage. Features: - Low profile - Glass-passivated chip - Excellent clamping behavior - Fast response time - MSL Level 1, per J-STD-020 - Plastic housing has UL 94 V-0 - Safety certification UL 497B, E478010 Identical design: - DO-214AC = SMAJ - DO-214AA = SMBJ - DO-214AB = SMCJ/SMDJ...
... hardware features one CAN interface each. The core component is an ARM11 processor with a clock speed of 532 MHz. The PLC comes with 128 MB DDR2-SDRAM and 32 MB NOR-Flash as standard. Optional memory upgrades are available, allowing expansion to 256 MB DDR2-SDRAM and 64 MB NOR-Flash, and further enhancement with an SD card. The housing, rated IP20, measures 98 x 210 x 35 mm. The handheld device is equipped with a flexible connection cable through which it is powered and connected to the bus.
... optionally can be mounted separately Measuring unit housing rotatable 3V lithium battery Battery life of 6 years plus 1 year reserve Optical interface according to ZVEI Optionally expandable with plug-in modules: M-Bus, KNX, LON, Wireless M-Bus, Pulse...
Austria, Salzburg
...mini CORI-FLOW Compact Coriolis mass flow meter/controller for small and very small flow rates, IP-65 housing, BUS interfaces, media range stainless steel. BRONKHORST mini CORI-FLOW mass flow meters and controllers are suitable for very low flow rates. They feature a compact design with a robust IP65 housing. With analog output, RS-232 communication, and optional fieldbus interface; secondary digital output for media temperature and density. Metal-sealed. Flow ranges from 0-5 g/h to 0-300 kg/h...
France, Neuillé
...> IP interface between computer network and RS485 fieldbus devices > Management of 2 RS485 buses, VDIP protocol to manage up to 120 readers and Apério protocol to manage up to 15 Apério locks per bus > RS232 connector for communication with external equipment > A second RJ45 socket with switch function > Radius authentication (802.1X) and support for SNMP protocol > Hood open contact > PoE power supply (or optional external) > ABS housing > H 210 mm x W 145 mm x D 65 mm...
Germany, Bamberg
...for individual requirements, modular, power/signal/bus/pneumatic/fiber optic cables in a connector Connection techniques: screw, crimp, spring Rated current: up to 150 A Rated voltage: up to 5.5 kV Number of poles: 2, 3, 4, 5, 10, 20 Contact surface: tin, silver, gold Protection class: IP54 and 65 Compatible housing series: BASIC...
... expansion module near the access point. Technical Specifications Housing dimensions (L x W): 298 x 285 x 78mm. PCB dimensions (L x W): 210 x 100mm. Housing dimensions (L x W): 298 x 285 x 78mm PCB dimensions (L x W): 210 x 100mm...
Switzerland, Reinach Bl
...turbulence, the presence of gas bubbles, foam, vibrations, or clogging. Measurement Principle: Vibronic / Liquids Characteristic / Application: Modular housing concept; Wide range of process connections Analog and bus interfaces Specialties: Foam detection Density change detection 2nd line of defense Power Supply / Communication: PROFIBUS PA 19...253V AC 10...55V DC-PNP 19...253V AC or 10...55V DC 8/16 mA...
Germany, Düsseldorf
...The CANopen position signal of the encoder and the switching outputs can be parameterized separately. Parameterization is carried out via the corresponding CANopen objects according to the encoder profile per CiA, DS 406, Revision 4.01. The NOCN features error monitoring that outputs an error message via the CANopen bus upon detection of a fault (Emergency Message). Interface: CANopen, Relay...
... medium:: Neutral gases, air DIN ISO 8573-1 Installation position:: Any, display on top or side Operating pressure:: 1.4 to 7 bar Actuation system:: Single-acting and double-acting Air performance:: QNn = 100 lN/min at 7 bar; ΔT=1bar Protection class:: IP 65/67 according to EN 60529 Protection rating:: 3 according to VDE 0580 Conformity:: EMC 2004/108/EC Position detection module:: Potentiometer max. angle 180° Bus communication:: Profibus DP V1 (optional)...
Austria, Wien
...Polycarbonate light for wall and ceiling surface mounting in protection classes IP54 and IP65. Polycarbonate light with clear light cover Central battery: 230 V AC/DC or optionally 24V, 48V, 60V, and 110V DC Single battery: 1h, 3h, 8h standby/continuous operation, automatic self-test, bus monitoring possible Dimensions (WxHxD mm): 370x140x90 mm Housing: Polycarbonate (clear light cover) Color...
...Optical scattered light smoke detector with base, for the safe early detection of smoldering fires with bright smoke development Suitability: dusty, dirty rooms Housing: ABS, LxWxH 100x80x30mm Protection class: IP65 Gas entry: Diffusion, sinter filter, protection class IP44 Power supply: 12-36 VDC Connection cable: JY (ST) Y 2x2x0.8 mm² Bus topology: RS 485...
France, La Wantzenau
... for RS422 / TTL (differential voltage > 0.5 V), Input level for differential HTL (differential voltage > 2 V), Input level for asymmetric HTL low: 0 … 6 V, high: 8 … 40 V Input level for TTL (asymmetric): LOW < 0.8 V, HIGH > 2.0 V Compact housing for mounting on 35 mm DIN rail (according to EN 60715) Dimensions L x H x D = 34 x 118 x 140 mm (1.34 x 4.65 x 5.51")...
Poland, Sulistrowa
... city metal benches without a backrest, which are the perfect complement to bus stops or sports fields. Our city benches are universal due to their timeless design and the use of materials resistant to weather conditions and corrosion. In addition to a huge selection, when buying seats in Elektron, you can also be sure of the highest quality and resistance to mechanical damage. As a manufacturer of metal benches with many years of experience, we know what materials to use to ensure consistently solid products.
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play