• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • electronic components

Results for

Electronic components - Import export

United KingdomYorkshire and the HumberDistributor

United Kingdom

Product Features: • Designed for push-pull tube output circuits. • Enclosed in a drawn steel case, the transformer is completely potted in epoxy. • Frequency response 30 Hz. to 30 Khz. at full rated power (+/- 1 db max. ref. • 1 Khz) minimum. • Lead connection is via 10 bottom mounted lugs. • All units include 40% screen taps for Ultra-Linear operation (if desired). • Finished in a black powder paint (to match the 300P Series power transformers). • Typical applications - Push-Pull: triode, Ultra-Linear pentode, pentode and tetrode connected audio output.

Request for a quote

United Kingdom

Product Features: • Designed for general purpose or replacement use in Push-Pull tube output circuits. • Frequency response: 150 Hz. - 15 Khz at full rated power (+/- 1 db max. ref. 1 Khz). • Open style with minimum 5" long primary leads. • Secondary solder lugs for convenient secondary connections (except 125B - uses minimum 5" secondary leads). • Primary impedances from 1,200 to 25,000 Ohms. • Secondary impedances from 1.5 to 15 Ohms.

Request for a quote

United Kingdom

Product Features: • Small, economical, open, two hole horizontal bracket mount. • Insulated, colour coded flexible leads, 4" long minimum (143, 144 and 145 Series) or 3" long minimum (146 Series). • Frequency response 150 Hz. to 15 Khz. (+/- 1 db, reference 1000 Hz.). • When operating at impedances below nominal, power capability and the frequency spectrum are proportionately lower, conversely, at higher impedances power capability and frequency spectrum will be proportionately higher. • Net weight: 0.5 oz. (143, 144, 146 Series) and 1.4 oz. (145 Series).

Request for a quote

United Kingdom

Product Features: • Designed for push-pull tube output circuits. • Enclosed (shielded), 4 slot, above chassis Type "X" mounting. • Frequency response 30 Hz. to 30 Khz. at full rated power (+/- 1 db max. - ref. 1 Khz.) minimum. • Insulated flexible leads 8" min. • Manufactured with plastic coil forms for coil support and insulation. • Typical applications - Push-Pull: triode, Ultra-Linear pentode, pentode and tetrode connected audio output. • Due to the unique interleaving of the windings BOTH secondary windings must be engaged to meet specifications.

Request for a quote

United Kingdom

Product Features: • Designed for push-pull tube output circuits. • Units are designed to provide ample "headroom" at bass frequencies (note the weight of each transformer). • All models have a secondary tapped fro 4, 8 or 16 ohm outputs. • Enclosed (Shielded), 4 slot, above chassis Type "X" mounting. • Manufactured with plastic coil forms for coil support and insulation. • Frequency response 30 Hz. to 30 Khz. at full rated power (+/- 1 db max. - ref. 1 Khz.) minimum. • Insulated flexible leads 8" min. • All units (except the 1650G) include 40% screen taps for Ultra-Linear operation (if desired). • Typical applications - Push-Pull: triode, Ultra-Linear pentode, pentode and tetrode connected audio output. The 1650G does NOT have primary screen taps and will not support "Ultra Linear" applications.

Request for a quote

United Kingdom

Product Features: • Designed for drop is replacement of original units. • Physically, parts were designed to look similar to original factory units (where possible). • Inductance measured at rated D.C. current. • Material used and design specs. were kept at close as possible to the original part to preserve the stock "tone". • Units are vacuum impregnated with polyurethane varnish for quiet and long life operation.

Request for a quote

United Kingdom

Product Features: • Perfect for high frequency filtering applications. • High permeability core ideal for applications under 50 kHz. • High self-resonant frequency values. • Operating Frequency: 60Hz. - 10kHz. • Some models feature universal channel mount packaging with flexible insulated leads (6" min.). • Some models feature rugged construction with aluminium base and stainless steel band along with open-style terminals for maximum versatility.

Request for a quote

United Kingdom

Product Features: • Moulded powdered iron core. • All chokes include vinyl insulation cover. • 1.25" long leads (+/- 0.1"). • High inductance and high current. • L measured at 7.9 Mhz. on 1536D, E and F all others at 1 Khz.

Request for a quote

United Kingdom

Product Features: • Large ferrite core for extended saturation point, optimum frequency range .01-2 Mhz. • 1.5" long leads (+/- 0.1"). • Test frequency 1 Mhz. • Core length 1.25". • Coil is covered with vinyl insulation shrink sleeve. • Operating temperature -55°C to +135°C.

Request for a quote

United Kingdom

Product Features: • High saturation flux density ferrite rods. • 1" long leads, tinned to within 1/8" of body. • Ideal for filtering or energy storage inductors. • Inductance measured at @ 1 Khz. with 0 amps. D.C. current, typical inductance change is less than 5% @ twice rated current. • Ambient temperature range -60C to +85C.

Request for a quote

United Kingdom

Product Features: • Toroidal design. • Supplied with 24" insulated secondary leads, terminated with crimped ring connectors. • Suitable for use with bare (uninsulated) primary conductor in circuits up to 600 V (4 KV Hi pot); or at higher voltage when a suitably insulated conductor is used. • All units have 5 A secondary for use with standard AC ammeters with 5 A movements. • Two hole mounting bracket on all models. • UL E227616 volume #1 file number X0DW2

Request for a quote

United Kingdom

Product Features: • Designed for a 5 amp. primary (maximum 20 Amp), secondary current 5 ma. • 40 - 1,000 Hz. operation. • Customer to supply primary winding (1 turn through open top of transformer bobbin). • Two hole chassis mount or P.C. board pin mont. • Both units have 5 ma. secondary for use with standard AC ammeters with 5 ma.movements. • High accuracy windings (1%).

Request for a quote

United Kingdom

Product Features: • Used (with 150 Volt full scale A.C. voltmeters) to measure the voltage of 240, 480 or 600 VAC systems. • Primary insulated for 4.0 KV rms test, suitable for L.V. switchgear and motor control use. • 50/60 Hz. operation. • Open construction - "Type H". • CSA certified (209651). • The nominal line voltages of 240 and 480 volts may be exceeded by 25% for 60 Hz. operation. • Insulation system 55°C rise, Class 105.

Request for a quote

United Kingdom

Product Features: • Used to measure the voltage of 120 VAC systems with 5 Volt full scale A.C. voltmeters. • 50/60 Hz. operation. • Choice of chassis mount or P.C. board pin mount. • High accuracy windings (1%). • VA rated for 0.020 VA.

Request for a quote

United Kingdom

Product Features: • Used in chimes, door bells, security systems, decorative lighting, furnaces, humidifiers, appliances, vending machines, intercom system type applications. • Rugged, low noise, cool running design, indoor use only. • Stripped wire input (primary) leads, screw terminal/quick fit tab terminal output (secondary). • Nipple locknut mount for box installation, complete with locknut and mounting bracket. • Input leads are black, on 240V models 240V lead is read. All models are 60 Hz. - inherently limited - no fuses or circuit breakers. • UL listed #E184371 - Except for part numbers BE2F and BE7G. • CSA certified (209651).

Request for a quote

United Kingdom

Product Features: • Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is required. • Flexible world wide applications, 50 or 60 Hz. operation, step down (230VAC to 115VAC) or step up (115VAC to 230VAC). • Totally enclosed rear case, includes handy internal grounding bolt. • Extra vacuum varnish for use in high humidity. • Includes a rear mounted (but not wired), standard 115VAC, 3-wire receptacle. • Enclosed case with convenient knockouts and includes two cable clamps allowing for easy wire connections. • Models 170SE, 170AW, 170BE, 170CE and 170DE are CSA certified (209651). • Connection by flexible leads, 8" minimum length. • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Primary 230VAC, 50/60 Hz. Secondary 115VAC. • Circuit breaker in primary. • Provides circuit isolation and steps down primary voltage. • Hi-pot tested to 2 KV RMS. • Electrostatic shield between primary and secondary. • Input (Primary) connected to a 5 foot long cord and European (Schuko) grounded plug - note: Old inventory only. • Input - due to U.L. changes in 2007 - New production with the European (Shuko) parts would no longer be U.L. listed. Therefore, we have replaced this input plug with a standard North American 3-wire, 250V plug (NEMA 6-15P). • Output (Secondary) connected to a 1 foot long cord and standard North American 3-wire grounded receptacle (NEMA 5-15R). • North American Mark of Safety - C UL and UL listed (File #E211544). • Indoor use only. • Remember - These units do NOT convert line frequency.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

United Kingdom

Product Features: • Intended for non-patient connected indoor applications where protection of sensitive electronics is required: • High end audio / studio use • Medical electronics • High end test equipment / laboratory • cULus Listed to UL 60601-1 (1st Edition) and CAN/CSA-C22.2 No. 601.1-M90 (R2005). • Each unit provides complete line isolation and noise filtering plus utilizes a Faraday shield to reduce leakage currents below UL60601-1 requirements (under 100 microamps). • Reduced noise coupling due to floating AC output. • Not included to be used to supply power to life support appliances. • 3 Different VA Capacities available - 500VA, 1000VA and 1800VA. All rated 50/60 Hz. • 4 Different electrical configurations: • 120V-120V Straight isolation ("178" Series) • 240V-240V Straight isolation ("240" Series) • 240-120V Step down isolation ("289" Series) • 120-240V Set up isolation ("298" Series)

Request for a quote

United Kingdom

Product Features: • Designed with nickel alloy cores for high performance and Wide Bandwidth. • Frequency Response: 20 Hz - 20 kHz ±0.35 dB, (ref. @ 1 kHz). • Low distortion at levels up to +27 dBu @ 20 Hz. • Excellent Shielding - Mu Metal Enclosures. • Line Output Transformers are open style (not Mu Metal).

Request for a quote

United Kingdom

Product Features: • Designed for drop is replacement of original units. • Physically, parts were designed to look similar to original factory units (where possible). • Inductance measured at rated D.C. current. • Material used and design specs. were kept at close as possible to the original part to preserve the stock "tone". • Units are vacuum impregnated with polyurethane varnish for quiet and long life operation.

Request for a quote

United Kingdom

Product Features: • Designed for drop is replacement of original units. • Physically, parts were designed to look similar to original factory units (where possible). • Inductance measured at rated D.C. current. • Material used and design specs. were kept at close as possible to the original part to preserve the stock "tone". • Units are vacuum impregnated with polyurethane varnish for quiet and long life operation.

Request for a quote

United Kingdom

Product Features: • Heavy duty design with plastic shell and double wipe contacts. • Indoor use only. • Allows for ground connection between equipment and international power sources. • With a set of all 4 adaptors, they will accept equipment with plugs from virtually every country except South Africa. • Adaptors do not affect voltages, they are a mechanical device only to match foreign "pin-outs" of receptacles and/or plugs.

Request for a quote

United Kingdom

Product Features: Primary 120VCA, 50/60 Hz., Secondary 240VAC. Provided circuit isolation. • Torodial transformer for high isolation, low noise, light weight cool operation and low profile. • 50 or 60 Hz. operation, step up (120VAC to 240VAC). • Standard 3-wire, grounded plug (can also be used with adaptors for proper grounding). • Input (primary) connected to a 5 foot cord and standard North American plug (NEMA 5-15P). • Output (Secondary) connected to a standard North American duplex - 3 wire grounded receptacle (NEMA 6-15R). • Transformer Hi-Pot test of 4,000V RMS between primary and secondary. • Features include ventilated black steel case with rocker lighted on-off switch and circuit breaker protected output. • North American Mark of Safety - C UL and UL listed (File #E211544). • Indoor use only. • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Primary 240VAC, 50/60 Hz., Secondary 120VAC. • Provides circuit isolation. • Toroidal transformer for high isolation, low noise, light weight, cool operating and low profile. • World wide applications, 50 or 60 Hz. operation, step down (240VAC to 120VAC). • Standard 3-wire, grounded plug (for use with adaptors for proper grounding). • Input (Primary) connected to a 5 foot long cord and standard 250V 2 pole, 3 wire - North American plug (NEMA 6-15P). • Output (Secondary) connected to two standard - 3 wire grounded receptacles (NEMA 5-15R). • Features include ventilated black steel case, rocker lighted on-off switch and circuit breaker protected output. • North American Mark of Safety - C UL and UL listed (File #E211544). • Indoor use only. • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Primary 240VAC, 50/60 Hz., Secondary 240VAC. • Provides circuit isolation. • Toroidal transformer for high isolation, low noise, light weight, cool operation and low profile. • World wide applications, 50 or 60 Hz. operation (240VAC to 240VAC). • Standard 3-wire, grounded plug (for use with adaptors for proper grounding). • Input (Primary) connected to a 5 foot long cord and standard North American Plug (NEMA 6-15P). • Output (Secondary) connected to a standard - 3 wire grounded duplex receptacle (NEMA 6-15R). • Features include ventilated black steel case, rocker lighted on-off switch and circuit breaker protected output. • North American Mark of Safety - C UL and UL listed (File #E211544). • Indoor use only. • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is required. • World wide applications, 50 or 60 Hz. operation, step down (230VAC to 115VAC). • Input is circuit breaker protected. • Hi-pot tested to 2 KV RMS. • Input is a standard 250V North American, 3-wire, grounded plug (can also be used with adaptors for proper grounding). • Input on "-NA" version - connected to a 5 foot cord and grounded North American 250V plug (NEMA 6-15P). • Output connected to a one foot long "pig tail" cord with standard North American 115V - 3 wire grounded receptacle (NEMA 5-15 R). • North American Mark of Safety - C UL and UL listed (File #E211544). • Indoor use only. • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Primary 115VAC, 50/60 Hz., Secondary 115VAC. • Provides complete circuit isolation. • Electrostatic shield between primary and secondary to greatly attenuate • surges and noise. • Hi-pot tested to 2 KV RMS. • Circuit breaker in primary. • Standard 3-wire, grounded plug and receptacle. • Input (Primary) connected to 5 foot long cord and standard North American plug (NEMA 5-15P). • Output (Secondary) connected to a foot long "pig tail" cord, 3-wire, standard North American grounded receptacle (NEMA 5-15R). • North American Mark of Safety - C UL and UL listed (File #E211544). • Indoor use only. • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Single winding, does not provide isolation, for use where equipment is already isolated and only voltage changed is required. • Flexible world wide applications, 50 or 60 Hz. operation, step down (230VAC to 115VAC) or step up (115VAC to 230VAC). • Connections by flexible leads, 8" minimum length. • Models 170A, 170B, 170C and 170D are CSA certified (209651). • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Primary 115VAC, 60 Hz., Secondary 115VAC. • Electrostatic shield between primary and secondary. • Connection by flexible leads, 8" minimum length. • Perfect for circuit isolation or "Classic" bias power supply. • CSA certified (209651).

Request for a quote

Request for quotes

Create one request and get multiple quotes form verified suppliers.

  • Only relevant suppliers
  • Data privacy compliant
  • 100% free