High frequency controllers, eddy currents and sometimes poor electrical guidance can result in electrical charge separation in bearings causing electrical discharge through the lubricant film. As a consequence metallic material is molten locally causing damage on raceways and balls of the bearing. Non-conducting lubricants suffer locally from severe thermal degradation. Solution: Lubcon electrically conductive greases prevent high level charge separation by conducting even at low electrical potential differences and therefore prevent premature bearing failure e.g. in frequency controlled electric motors.