Product Features: • Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is required. • World wide applications, 50 or 60Hz. operation, step up (115VAC to 230VAC). • Input is circuit breaker protected. • Hi-pot tested to 2 KV RMS. • Input is a standard 3-wire, grounded plug (can also be used with adaptors for proper grounding). • Input is connected to a 5 foot cord and standard grounded North American plug (NEMA 5-15P). • Output - Due to U.L. changes in 2007 - New production with the European (Shuko) parts would no longer by U.L. listed. Therefore, Hammond replaced this output receptacle with a one foot long "pig tail" cord with a standard North • American 3-wire, 250V receptacle (NEMA 6-15R) for any production after the first part of 2008. • North American Mark of Safety - C UL and UL listed (File #E211544). • Indoor use only. • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: Primary 120VCA, 50/60 Hz., Secondary 240VAC. Provided circuit isolation. • Torodial transformer for high isolation, low noise, light weight cool operation and low profile. • 50 or 60 Hz. operation, step up (120VAC to 240VAC). • Standard 3-wire, grounded plug (can also be used with adaptors for proper grounding). • Input (primary) connected to a 5 foot cord and standard North American plug (NEMA 5-15P). • Output (Secondary) connected to a standard North American duplex - 3 wire grounded receptacle (NEMA 6-15R). • Transformer Hi-Pot test of 4,000V RMS between primary and secondary. • Features include ventilated black steel case with rocker lighted on-off switch and circuit breaker protected output. • North American Mark of Safety - C UL and UL listed (File #E211544). • Indoor use only. • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Primary 240VAC, 50/60 Hz., Secondary 120VAC. • Provides circuit isolation. • Toroidal transformer for high isolation, low noise, light weight, cool operating and low profile. • World wide applications, 50 or 60 Hz. operation, step down (240VAC to 120VAC). • Standard 3-wire, grounded plug (for use with adaptors for proper grounding). • Input (Primary) connected to a 5 foot long cord and standard 250V 2 pole, 3 wire - North American plug (NEMA 6-15P). • Output (Secondary) connected to two standard - 3 wire grounded receptacles (NEMA 5-15R). • Features include ventilated black steel case, rocker lighted on-off switch and circuit breaker protected output. • North American Mark of Safety - C UL and UL listed (File #E211544). • Indoor use only. • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Primary 240VAC, 50/60 Hz., Secondary 240VAC. • Provides circuit isolation. • Toroidal transformer for high isolation, low noise, light weight, cool operation and low profile. • World wide applications, 50 or 60 Hz. operation (240VAC to 240VAC). • Standard 3-wire, grounded plug (for use with adaptors for proper grounding). • Input (Primary) connected to a 5 foot long cord and standard North American Plug (NEMA 6-15P). • Output (Secondary) connected to a standard - 3 wire grounded duplex receptacle (NEMA 6-15R). • Features include ventilated black steel case, rocker lighted on-off switch and circuit breaker protected output. • North American Mark of Safety - C UL and UL listed (File #E211544). • Indoor use only. • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Primary 120VAC, 50/60 Hz., Secondary 120VAC. • Provides circuit isolation. • Toroidal transformer for high isolation, low noise, light weight, cool operation and low profile. • World wide applications, 50 or 60 Hz. operation, step down (120VAC to 120VAC). • Standard 3-wire, grounded plug (for use with adaptors for proper grounding). • Input (Primary) connected to a 5 foot long cord and standard North American plug (NEMA 5-15P). • Output (Secondary) connected to two standard - 3 wire grounded receptacles (NEMA 5-15R). • Features include ventilated black steel case, rocker lighted on-off switch and circuit breaker protected output. • North American Mark of Safety - C UL and UL listed (File #E211544). • Indoor use only. • Remember - These units do NOT convert line frequency.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

United Kingdom

Product Features: • Primary 230VAC, 50/60 Hz. Secondary 115VAC. • Circuit breaker in primary. • Provides circuit isolation and steps down primary voltage. • Hi-pot tested to 2 KV RMS. • Electrostatic shield between primary and secondary. • Input (Primary) connected to a 5 foot long cord and European (Schuko) grounded plug - note: Old inventory only. • Input - due to U.L. changes in 2007 - New production with the European (Shuko) parts would no longer be U.L. listed. Therefore, we have replaced this input plug with a standard North American 3-wire, 250V plug (NEMA 6-15P). • Output (Secondary) connected to a 1 foot long cord and standard North American 3-wire grounded receptacle (NEMA 5-15R). • North American Mark of Safety - C UL and UL listed (File #E211544). • Indoor use only. • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Primary 115VAC, 50/60 Hz., Secondary 115VAC. • Provides complete circuit isolation. • Electrostatic shield between primary and secondary to greatly attenuate • surges and noise. • Hi-pot tested to 2 KV RMS. • Circuit breaker in primary. • Standard 3-wire, grounded plug and receptacle. • Input (Primary) connected to 5 foot long cord and standard North American plug (NEMA 5-15P). • Output (Secondary) connected to a foot long "pig tail" cord, 3-wire, standard North American grounded receptacle (NEMA 5-15R). • North American Mark of Safety - C UL and UL listed (File #E211544). • Indoor use only. • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is required. • Flexible world wide applications, 50 or 60 Hz. operation, step down (230VAC to 115VAC) or step up (115VAC to 230VAC). • Totally enclosed rear case, includes handy internal grounding bolt. • Extra vacuum varnish for use in high humidity. • Includes a rear mounted (but not wired), standard 115VAC, 3-wire receptacle. • Enclosed case with convenient knockouts and includes two cable clamps allowing for easy wire connections. • Models 170SE, 170AW, 170BE, 170CE and 170DE are CSA certified (209651). • Connection by flexible leads, 8" minimum length. • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Single winding, does not provide isolation, for use where equipment is already isolated and only voltage changed is required. • Flexible world wide applications, 50 or 60 Hz. operation, step down (230VAC to 115VAC) or step up (115VAC to 230VAC). • Connections by flexible leads, 8" minimum length. • Models 170A, 170B, 170C and 170D are CSA certified (209651). • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Primary 115VAC, 60 Hz. • Secondary taps @ 90, 100, 110, 115, 120 and 130 VAC. • Electrostatic shield between primary and secondary. • Connection by flexible leads, 8" minimum length. • Perfect for critical line voltage needs (examples: Older "Classic" tube equipment or Japanese 100V equipment). • CSA certified (#LR3902) - except 169J. • Remember - These units do NOT convert line frequency.

Request for a quote

United Kingdom

Product Features: • Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is required. • Flexible world wide applications, 50 or 60 Hz. operation, 115VAC input. • Output taps @ 85, 95, 105, 110, 115 and 125VAC. • Ideal for manual line voltage adjustment for electronic equipment or small appliance operation. • Models 168B, 168C and 168D are CSA certified (209651). • Connection by flexible leads, 8" minimum length. • Remember - These units do NOT convert line frequency.