• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • domestic hot water

Results for

Domestic hot water - Import export

United Kingdom

United Kingdom

Use these Advance Thermal Stores for the provision of fast, safe hot water provision throughout the house. The indirect pattern cylinder (TSiC) without the integrated feed and expansion tank has to be fed with a remote F and E tank but can be sited anywhere in the property. They have two coils, the lower one for heat input from a boiler, the higher one for mains fed hot water services. They can be used with sealed system boilers and heating circuits on Y plan systems. These low maintenance pre plumbed units provide flow rates up to 30 litres per minute and if linked to the appropriate gas, oil, or LPG boiler are suitable for average to larger properties. The bottom coil must be pumped. The units look smart too, with a wipe-clean white appliance finish, and the insulation is 60mm foam injected for maximum efficiencies. Stainless steel construction offers a lightweight long life product. The stores are guaranteed for ten years, the parts for two.

Request for a quote

United Kingdom

Use these Advance Thermal Stores for the provision of fast, safe hot water provision throughout the house. The indirect pattern (TSi) Twin Coil with the integrated feed and expansion tank can be sited anywhere in the property. The lower coil can be connected to a sealed system boiler in a Y plan, thus only one pump is needed. The store remains vented, with the contents of the store used as a medium for heat transfer only. These low maintenance pre plumbed units provide flow rates up to 30 litres per minute and if linked to the appropriate gas, oil, solid fuel, biomass or other appliance (except Heat Pumps) are suitable for average to larger properties.

Request for a quote

United Kingdom

Use these Advance Thermal Stores for the provision of fast, safe hot water provision throughout the house. They work on the thermal store principle of storing central heating water and providing mains fed hot water via a powerful coil for power showering and quick bath filling. The coil is not pumped. The thermal store acts as a buffer for fast radiator heat up and boiler efficiency. The direct pattern cylinder (TSDC) without the integrated feed and expansion tank has to be fed with a remote F and E tank sited above the highest point of the radiator circuit. You need two pumps - one for the boiler to keep the store hot - controlled by the thermostat on the store, and one for the heating circuit - controlled by the room thermostat and heating programmer. These low maintenance pre plumbed units provide flow rates up to 30 litres per minute and if linked to the appropriate gas, oil, solid fuel or biomass(except Heat Pumps) are suitable for average to larger properties

Request for a quote

United Kingdom

The HETAS listed SFUTS pre plumbed pre wired Universal Thermal Store has been designed to link a number of heat sources including gas or oil boilers, wood burners, and solar thermal or PV as well as electric and other inputs. Hot water is safely delivered at mains pressure through a large integral coil for fast bath filling and power showering without a pump. In summer the solar coil, if utilised, will provide most of your hot water needs. In the winter the wood burner, when lit, will handle most of the heating and hot water duties. Central heating is taken from the store which acts as a buffer for fast radiator or under floor heat up. The store is kept hot by the energy inputs controlled by thermostats. Because the unit is a sealed system it is fine for under floor systems. The primaries are 28mm and can be teed off for two separate circuits if required.

Request for a quote

United Kingdom

The Advance Solar EnergyManager is a tried and tested thermal store design with an internal heat exchanger and shunt pump arrangement resulting in delivery of hot water equivalent to the volume of the tank at 43ºC. The solar version has a dedicated solar coil which reduces energy bills and reliance on fossil fuel. The solar thermal panels will contribute to heating and hot water during periods of solar gain. The shunt pump is pre fitted and wired to activate when taps or showers are turned on. The EnergyManager comes as shown above with wiring centre for installers to complete the wiring for the rest of the system. Full instructions for wiring the total system are included. At 65ºC operation the EnergyManager is perfect for underfloor or low temperature radiator circuits and offers efficiencies due to the temperature being lower than most thermal stores. As a thermal store it can reduce boiler cycling and act as a buffer for heating.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

United Kingdom

The Advance EnergyManager is a tried and tested design with an internal heat exchanger and shunt pump arrangement resulting in delivery of hot water equivalent to the volume of the tank at 43ºC. It works on the thermal store principle of storing primary (central heating) water and delivering mains pressure hot water through a heat exchanger. The shunt pump is pre fitted and wired to activate when taps or showers are turned on. The EnergyManager comes as shown above with wiring centre for installers to complete the wiring for the rest of the system. Full instructions for wiring the total system are included. At 65ºC operation the EnergyManager is perfect for underfloor or low temperature radiator circuits and offers efficiencies due to the temperature being lower than most thermal stores. It delivers hot water equivalent to the capacity of the store.

Request for a quote
Filters

Results for

Domestic hot water - Import export

Number of results

7 Products