Toroid Current Transformers must be used together with Earth Leakage Protection Relay and Toroid Transformers for their compatible operation. Specially designed sealable top cover suitable for DIN Rails. Adjustable earth leakage current threshold value from 30mA to 30A. Adjustable time delay from 0,05 to 3 seconds. Opening time: +- 15%
Request for a quoteBelgium
"Our stock consists of about 100 transformers (low and high voltage) up to 3MVA that can be rented or sold. We find power transformers in different types of applications: in electrical transmission networks, in electrical distribution and in factories. Characteristics of low voltage transformers: - 2 types: isolation transformers and autotransformers - Three-phase dry-type transformers delivered up to 2000 kVA Mainly available in 230/400V or 400/400V or 400/500V or 400/690V - Other primary and secondary voltages on request - Stored as new up to 160 kVA - With or without IP20 protection cover - Aluminium or copper windings - Special design for particular application on request - Rental possibility: Our transformers can be rented for construction sites or for repair purposes."
Request for a quoteBelgium
"Our stock consists of about 100 transformers (low and high voltage) up to 3MVA that can be rented or sold. We find power transformers in different types of applications: in electrical transmission networks, in electrical distribution and in factories. Characteristics of high voltage transformers: - 2 types of cooling: dry and oil - Transformers supplied up to 10MVA - Extra low loss design for the European market or other lossy design for export - Aluminium or copper windings - Special design for special application on request - Rental possibility: Our transformers can be rented for construction sites or for repair purposes."
Request for a quoteBelgium
"Our stock consists of about 40 transformers (low and high voltage) up to 3MVA that can be rented or sold. We find power transformers in different types of applications: in electrical transmission networks, in electrical distribution and in factories."
Request for a quoteGermany
Our mid range frequency converters are delivering up to 250 kW output at frequencies down to 4 kHz. For high frequencies up to 2 MHz we have our high frequency converter series HU.
Request for a quoteGermany
Discover the outstanding properties of our high-quality transformer oil. Developed for demanding applications in transformers, converters, switches and capacitors, the transformer oil offers first-class performance and reliability. Manufactured in Germany by premium supplier.
Request for a quoteTurkey
Transformer coating rectifiers are produced in Turkey under the Alphaworld brand. Domestic production transformer coating rectifiers are under warranty for 2 years against manufacturing and workmanship defects. All products produced by Alphaworld have a 15-year spare parts warranty. Technical service is provided 24 hours a day, 7 days a week in 81 provinces. Technical information of our product is in the detail section below. Transformer Coating Rectifier Prices Provide Savings! Transformer coating rectifier is a thyristor and variac controlled device used in different coating applications. The device is controlled via microprocessor. The microprocessor gives users application flexibility. Coating rectifiers are offered to users as GRA, GRW, GRO series. The device has different cooling options. Cooling varies depending on the working environment and the process to be applied. In addition to the air-cooled option, there are also oil-cooled and water-cooled options.
Request for a quoteTurkey
Transformer - Thyristor Controlled battery charger rectifiers are produced in Turkey under the Alphaworld brand. Domestic production transformer battery charger rectifiers are under warranty for 2 years against manufacturing and workmanship defects. All products produced by Alphaworld have a 15-year spare parts warranty. Technical service is provided 24 hours a day, 7 days a week in 81 provinces. Technical information of our product is in the detail section below. Gain Efficiency with Transformer Battery Charger Rectifier Prices Transformer battery charging rectifier is designed to meet battery charging needs in different sectors. The device works with a thyristor controlled by a microprocessor. Thyristor, which passes current in one direction, is a semiconductor circuit switching element. Microprocessor-controlled thyristors can control device current and voltage characteristics such as firing angle.
Request for a quoteBelgium
Maintenance Partners offers a full maintenance solution for oil filled and dry transformers. We offer services for distribution and power transformers of all brands, including: ACEC BBC Helmke Siemens AEG Brush Holec Smit Alstom France Transfo I.E.O. Stromberg ASEA G.E.C. Pauwels / CG Trafo Union Assessment & Maintenance Plan Transformers are low maintenance, but not free of maintenance. To determine the maintenance need of your transformer(s), Maintenance Partners offers an assessment that consists of visual inspections, oil sampling, thermography and electrical measurements. The assessment is the foundation for a maintenance plan in which the condition and priority of each transformer are decisive for the maintenance frequency and needs. Preventive Maintenance For a safe and reliable operation of transformers, preventive maintenance is a must. This detects problems at an early stage and can prevent further deterioration. Preventive maintenance includes the following tests: Oil.
Request for a quoteBelgium
Assessment & Maintenance Plan Transformers are low maintenance, but not free of maintenance. To determine the maintenance need of your transformer(s), Maintenance Partners offers an assessment that consists of visual inspections, oil sampling, thermography and electrical measurements. The assessment is the foundation for a maintenance plan in which the condition and priority of each transformer are decisive for the maintenance frequency and needs. Transformatoren Maintenance Partners - Preventief Onderhoud - StaalnamePreventive Maintenance For a safe and reliable operation of transformers, preventive maintenance is a must. This detects problems at an early stage and can prevent further deterioration. Preventive maintenance includes the following tests: Oil sampling + analysis (Oil quality, PCB, furan detection, moist level, …) Electrical measurements (Insulation resistance, Winding resistance, Transformer Turn Ratios, SFRA-Sweep Frequency Response Analysis, IDAX- Tgδ, …)
Request for a quoteUkraine
A transformer is a device for converting electric energy at one voltage level to electric energy at another voltage level through the action of a magnetic field. It plays an extremely important role in modern life by making possible the economical long-distance transmission of electric power. Most power system transformers fall into two types of construction, dry-type or liquid-immersed type. Dry-type include air insulated and solid insulated construction. Solid insulation is usually an epoxy resin. Liquid-immersed types use various forms of oil and special synthetic liquids. These transformers usually have some form of an external radiator to dissipate the heat generated internally by the windings and the core. The radiator is often the surfaces of the tank specially folded into corrugated fins or is in the form of fins, which are attached to the tank sides. We offer: Dry Type Transformers, Liquid-immersed (Oil Filled) Transformers, Transformers For Concrete Heating.
Request for a quoteGermany
Twopole and singlepole auxiliary voltage transformers designed to supply control cubicle with low voltage power.
Request for a quoteFrance
Specifications voltage: 1 x 12V current: 1 x 2000mA rated power: 24VA weight: 820g dimensions
Request for a quotePoland
33% of active substances: VECTICELL™ HA, Glycohyal LW, HYDROXYAPATITE, Argan oil, squalene » elixir with a filler-like effect » luxury formula » point or total application » perfect for the eye area » maintains the effects of professional treaments when used between treatments Use: » at the end of professional mesotherapy treatments » intense moisturizing and wrinkle-filling treatment » maintenance care for treatments using hyaluronic acid » recommended application 1-2 times a day with Transform HA Filler
Request for a quoteBelgium
Three-phase isolating transformer Identification Article number: SPT1000/D Code: 1730 EAN code: 5414503105196 Brand: EREA Type: Isolating transformer Electrical characteristics Power (VA): 1000 Primary voltage AC (Vac): 400 Secondary voltage AC (Vac): 230 - 400 Frequency (Hz): 50-60 Dielectric constant (Vac): 4500 Dielectric constant in relation to mass (Vac): 2500 Insulation resistance (MΩ): 200 Yield (%): 93 Pcu (W): 47,0 Po (W): 22,5 Voltage drop (dU%): 4,7 General characteristics Standards: EN 60742, EN 61558-2-4 Application: ...
Request for a quoteBelgium
Three-phase isolating transformer Identification Article number: SPT1600/D Code: 1731 EAN code: 5414503105202 Brand: EREA Type: Isolating transformer Electrical characteristics Power (VA): 1600 Primary voltage AC (Vac): 400 Secondary voltage AC (Vac): 230 - 400 Frequency (Hz): 50-60 Dielectric constant (Vac): 4500 Dielectric constant in relation to mass (Vac): 2500 Insulation resistance (MΩ): 200 Yield (%): 94,0 Pcu (W): 52,0 Po (W): 45,5 Voltage drop (dU%): 3,15 General characteristics Standards: EN 60742, EN 61558-2-4 Applicatio...
Request for a quoteDo you sell or make similar products?
Sign up to europages and have your products listed
Germany
Pressure relief devices for liquid-immersed transformers open in case of an internal fault and guarantee that the occured overpressure can properly release. Pressure relief devices close with decreasing pressure back to completely closed and leaktight position. Pressure relief devices for transformers can be installed in any position or inclination on the cover or the wall of a transformer. Upon request a transformer can be equipped with several pressure relief valves.
Request for a quoteGermany
The magnetic oil level indicator 1 225 with vertical float movement is used for hermetically sealed transformers. The float movement is transmitted to the display by means of a magnetic clutch. This ensures that, in case of damage to the dome, no oil leakge of the transformer occures. The body is made of brass. The thread connection of the oil level indicator 1 225 is 1 ½".
Request for a quoteGermany
The oil drain device Type C2 is used for oil sampling or emptying the transformer tank. The device is welded into the transformer case. The device is designed for use together with connection pipe F DIN 42551 for draining the transformer case for regeneration purpose of the oil. The oil drain device Type C2 is deisgned in accordance with EN 50216-4:2002 type C2.
Request for a quoteGermany
Dehydrating breathers are being used for liquid immersed transformers in order to protect the insulating liquid and prevent the harmful moisture absorption from ambient air, which occurs when the load on the transformer fluctuates.The dehydrating breather removes practically all moisture from the air that flows through it into the conservator when the transformer is cooling down. This largely prevents any reduction of the dielectric strength and the formation of condensation in the expansion tank. Thus, the dehydrating breathers increases the operational safety of transformers.
Request for a quoteGermany
The Buchholz Relay MBP in accordance with EN 50216-2 protects liquid immersed transformers and reactors with conservator. It will be mounted in the pipeline between transformer and conservator tank. The Buchholz Relay MBP operates as a protection device that can be provided with either two contacts or four contacts for alarm and tripping. Each Buchholzrelay is individually tested in a test facility for tightness and proper functioning.
Request for a quoteSlovakia
For many years, KUK Group has been a leading manufacturer of customer-specific transformers, chokes and transmitters - both for high frequency (HF) and low frequency (LF). We wind both standard and customer-specific bobbins. In close cooperation with the customer, we develop the best possible transformer or coil for the specific application. At the lowest possible costs. In addition, KUK is making more and more a name for itself as a supplier of sub-assemblies and a producer of medical transformer and distribution cabinets in hospitals, including installation and maintenance. - High-frequency transformers and coils with ferrite cores - One-phase and three-phase 50Hz transformers - Transformer and distribution cabinets for medical locations such as operating theatres, intensive care units and dialysis centres
Request for a quoteItaly
Transformers for cold cathode (neon lamps), designed and produced by F/ART in Italy Input: 120-240 V, 50/60 Hz Output: 990 V - 15,000 V Current Intensity: 18 - 200 mA -Exclusive epoxy resin is used to encapsulate and protect the product, making it durable. -Compliance with European standards and CE marking -Can be used for neon tube installations with an operating voltage between 1,000 V and 10,000 V, in compliance with European standards -Possibility to adjust the light using a dimmer: external switch for traditional transformers and built-in for electronic transformers -Casing for internal protection
Request for a quoteTurkey
Our transformer range : - Hermetic type distribution transformers - from 25kVA to 4000kVA - Conservator tank distribution transformers - from 25kVA to 8000kVA - Cast resin dry type transformers - from 25kVA to 10.000 kVA - Power transformers - from 2500kVA to 16000kVA - Box and special type transformers - Shunt reactor, Amorphous, Ground transformer All products are manufactured in high quality according to international standards.
Request for a quoteGreece
Output Tube Transformers We are able to manufacture EI Conventional and Toroidal Tube Output Transformers.
Request for a quoteUnited Kingdom
Shock Proof Screw terminals to UL and CSA standards Manufactured to BSEN61558 DESCRIPTION This range fulfills the requirements of control, safety and isolating transformers. Inrush currents and short circuit characteristics of ATL's transformers conform to up to date legislations and are compatible with all reputable manufacturers' switches breakers and magnetic release devices. All of our products are bespoke therefore voltages must be specified at enquiry stage. The transformers have protection against humidity and vibration. Our finger proof block terminals are shock proof and conform to BS EN & UL standards, other termination available please specify at enquiry stage. All of our transformers come complete with multiple footprints fixing centre's to enable a varied range of mounting configurations ref data sheet table. ** Click for more **
Request for a quoteUnited Kingdom
Solder tag terminated ATL range of small Solder tag transformers DESCRIPTION Small separating transformers with solder pin connections This range fulfils the requirements of control, safety and isolating transformers. Inrush currents and short circuit characteristics of ATL's transformers conform to up to date legislations and are compatible with all reputable manufacturers' switches breakers and magnetic release devices. All of our products are bespoke therefore voltages must be specified at enquiry stage. The transformers have protection against humidity and vibration. Our finger proof block terminals are shock proof and conform to BS EN & UL standards, other termination available please specify at enquiry stage. All of our transformers come complete with multiple footprints fixing centre's to enable a varied range of mounting configurations ref data sheet table. ** Click for more **
Request for a quoteUnited Kingdom
Panel & Stud termination Manufactured to BS EN61558 DESCRIPTION This range fulfills the requirements of control, safety and isolating transformers. Inrush currents and short circuit characteristics of ATL's transformers conform to up to date legislations and are compatible with all reputable manufacturers' switches breakers and magnetic release devices. All of our products are bespoke therefore voltages must be specified at enquiry stage. The transformers have protection against humidity and vibration. Our finger proof block terminals are shock proof and conform to BS EN & UL standards, other termination available please specify at enquiry stage. All of our transformers come complete with multiple footprints fixing centre's to enable a varied range of mounting configurations ref data sheet table. ** Click for more **