The Lascar EL-USB-TC-LCD Thermocouple Temperature Logger is specifically designed for use with thermocouple sensors. This temperature logger stores over 32,000 temperature readings from a Type J, Type K or Type T thermocouple. The data logger comes complete with a K-type sensor with a measurement range of 0 to 200°C.
Request for a quoteNetherlands
Meet the Lascar EL-WiFi-TC Temperature Logger WiFi, a powerful tool for remote temperature monitoring using an interchangeable J, K or T type thermocouple. With the supplied K Type probe, this logger measures temperatures from 0 to 200°C (32 to 392°F). The data is periodically uploaded via a standard WiFi network to the EasyLog Cloud or a single host PC. With the EasyLog Cloud you always have access to the temperature logger and all data collected, from any device connected to the internet. Adjust settings remotely, receive email notifications of alarm conditions, link sensors from multiple locations to one account, and assign multiple users.
Request for a quoteGermany
Use: Connectors for thermocouples and resistance thermometers measurement circuits. Suitable for measurement with small wires and mineral-insulated metal sheathed cables. Can be used for 4-wire RTD‘s. Mechanical design: • Housing of high quality fibreglass-filled thermoplastic plastic. • Contacts of original thermocouple materials and spring-loaded sockets for reliable contact. • Reverse polarity protection by different contact pin widths. • One-piece housing withstands great stresses. • Moulded barriers prevent short circuit. • Screw terminals enable quick connection.
Request for a quoteGermany
Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement point is hot junction insulated as standard to exclude any falsification of the measurement evaluation through superposition of the offsets. Sheathing thermocouples are freely flexible across their entire length. That means the thermocouple can be integrated in the installation point. The temperature to be measured can therefore be registered near the desired measuring point. A possible connection lead permits simple routing up to the measured-data acquisition. Options are available for the element diameter, element and wire length as well as the type of connection configuration (plug, socket, bare wire ends, etc.). Temperature range: -100 °C to +750 °C, continuous, depending on selected sheathing diameter and measuring medium or atmosphere
Request for a quoteGermany
Use: Multiple connectors for thermocouple and RTD circuits. Suitable for direct connection of up to 6 circuits simultaneously. Mechanical design: • Strong steel plate housing, coated with epoxy resin. • Anodised aluminium handle for easy disconnection of the plug connectors. • Available with contacts for 1 to 6 measurement circuits. • Corresponds with Standard Vertical Panel Type “PASV-(…)” and Sandard Multiple Jack Type “MJS-(…)”.
Request for a quoteGermany
Use: Enables neat connection of thermocouple cables to devices or terminal rails. This is advisable particularly in the case of small conductor dimensions. Mechanical design: • Solid thermocouple material.
Request for a quoteGermany
Use: Terminal rails enable the easy connection of thermocouples or resistance thermometer measurement circuits in junction boxes or on the rear side of devices. Mechanical design: • Core material of fibreglass-filled nylon • Insulators between the contacts prevent short-circuits. • Screw connections for easy installation. • Available in a wide range of thermo-pairings. • Dimensions suitable for the use of cable-shoes A-20.131-(…) and A-20.132-(…).
Request for a quoteGermany
Use: Panel insert for thermocouple and RTD circuits. Designed to used together with panel sets for assembly to complete standard panels. Mechanical design: • Housing of fibreglass-filled plastic. • Contacts of original thermocouple materials. • Spring-loaded sockets. • Reverse polarity protection by different pin thicknesses. • Moulded barriers prevent short-circuits. • Screw terminals enable quick connection. • Polarity designation next to the connection screws.
Request for a quoteGermany
Use: Miniature Jack/Socket for thermocouple and RTD circuits. Designed for direct soldering onto printed circuit boards. This version is suitable for flat mounting other versions available, please see separate specification sheet. Mechanical design: • Housing of fibreglass-filled plastic. • Contacts of original thermocouple materials and • spring-loaded sockets for reliable contact. • Moulded barriers prevent short-circuits. • Reverse polarity protection by different contact pin widths. • One-piece housing withstands great stresses.
Request for a quoteGermany
Use: Miniature Jack/Socket for thermocouple and RTD circuits. Designed for direct soldering onto printed circuit boards. This version is suitable for flat mounting other versions available, please see separate specification sheet. Mechanical design: • Housing of fibreglass-filled plastic. • Contacts of original thermocouple material and spring-loaded sockets for reliable contact. • Moulded barriers prevent short-circuits. • Reverse polarity protection by different contact pin widths. • One-piece housing withstands great stresses.
Request for a quoteGermany
Use: Miniature Jack/Socket for thermocouple and RTD circuits. Designed for direct soldering onto printed circuit boards. This version is suitable for flat mounting other versions available, please see separate specification sheet. Mechanical design: • Housing of fibreglass-filled plastic. • Contacts of original thermocouple materials and spring-loaded sockets for reliable contact. • Reverse polarity protection by different contact pin widths. • One-piece housing withstands great stresses.
Request for a quoteGermany
Use: Connectors for thermocouples and resistance thermometer measurement circuits. Suitable for measurement with small wires and mineral-insulated metal sheathed cables. Mechanical design: • Housing of fibreglass-filled plastic. • Contacts of original thermocouple materials and spring-loaded sockets for reliable contact. • Reverse polarity protection by different contact pin widths. • One-piece housing withstands great stresses. • Moulded barriers prevent short circuit. • Screw terminals enable quick connection.
Request for a quoteGermany
As mechanical connection elements, weld-on sockets are used wherever screw connections for measuring points need to be created quickly, reliably and economically. Along with standard weld-on sockets which is supplied in 1.4301 material, on request other materials such as special steels and alloys can also be used.