• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • terminal data

Results for

Terminal data - Import export

Germany

Verified by Europages

Small but powerful: This robust compact weighing terminal fitted with a verifiable data memory, stands out in many areas whether it is checking, order picking, packaging, dispatch, documenting or stocktaking. The versatile weighing terminal iS20 fulfills numerous tasks in a simple, fast and economical manner. A top performer for most company areas: In goods receiving and production, during quality assurance in the warehouse as well as in packaging and shipping. Integrated with applications for weighing and counting processes as well as tolerance control, this compact device supports your work flows in an effective and efficient manner.

Request for a quote

China

Verified by Europages

Terminal modules are used to stabilize the internal bus communication. When the number of adapter extension IO modules reaches 16 or more and terminal modules should be required. When the number of adapter extending IO modules is less than 16, and the terminal module CT-5810 only for dustproof could be selected. The dustproof terminal could cover the internal bus and field power supply hardware of the last IO module. And terminal modules have no process data and configuration parameters.

Request for a quote

Russia

SC/APC type PON connector

Request for a quote

Russia

Cable TV 1xRF output, SC/APC type PON connector, Broadcast storm control, ACL access control

Request for a quote

Germany

OEM Application in Microliter Dosage * Rugged design * High precision * Small form factor * Low weight * Good compatability of - geometry - control Catalog number 2709101 Software Download Power requirements: Supply voltage: 24VDC ± 5V Currents: Max.1A Resolution: 3000 steps Plunger drive: Principle: Quad encoder for loss of steps, detection of loss steps with error message Travel: 30mm Plunger speed: 1.2 sec. - 20 min./full stroke (speed ranges vary depending on syringe size and tubing) Syringes: Type: XP: 50µl, 100µl, 250µl, 500µl, 1.0ml, 2.5ml, 5.0ml Imprecision: 0.05% CV within run at full stroke (for 1000µl syringe and above) Inaccuracy: <1.0% at full stroke Fluid contact: Glass, PCTFE and Teflon Valve/valve drive: Valve options: 120° 3-port distribution Turn time: 250ms between adjacent ports Drive: Stepper motor with optical sensor for position detection Positions: Input, output, bypass Materials: Plug: virgin teflon Body: PCTFE Fittings: 1/4-28"-UNF screw fitting for syringe Interface: Type: RS 232, RS 485 or CAN bus Baudrate: 9.600 or 38.400, 100K or 125K (CAN bus) Format: Data bits: 8 parity: none Stop bits: 1 half duplex Addressing: up to 15 XP/AL devices can be addressed individually Communication: Data terminal and OEM protocol Firmware: Programmable ramps, cutoffs, backlash compensation, plunger speeds, delays and loops Arbitrarily selectable plunger speed Clearance compensation Absolute and relative positions Diagnostics Flash-PROM Environmental: Temperature: 17-37°C Humidity: 10-85% Non condensing RH at: 5°C-40°C Dimensions: Height: 127mm (+)1mm Width: 45mm (+)1mm Depth: 113mm Weight: 1.2kg

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business