Results for
Switzerland
The pressure transmitters of the 33X-Ei series use digital compensation with a mathematical model to achieve exceptional accuracy of 0,05 %FS – in the temperature range from 10 to 40 °C, this value even corresponds to the total error band. Additional measurements and selections can optionally be used to achieve a precision (and also, if calibrated in an accredited test laboratory, an accuracy) of 0,01 %FS. In addition to the digital RS485 interface, the X-line transmitters have a rangeable, analog current or voltage output. Intrinsically safe – suitable for use in explosive atmospheres.
Request for a quoteSwitzerland
The pressure transmitters of the 33X series use digital compensation with a mathematical model to achieve exceptional accuracy of 0,05 %FS – in the temperature range from 10 to 40 °C, this value even corresponds to the total error band. Additional measurements and selections can optionally be used to achieve a precision (and also, if calibrated in an accredited test laboratory, an accuracy) of 0,01 %FS. In addition to the digital RS485 interface, the X-line transmitters have a rangeable, analog current or voltage output.
Request for a quoteSwitzerland
The pressure transmitters of the 33X-Ed series use digital compensation with a mathematical model to achieve exceptional accuracy of 0,05 %FS – in the temperature range from 10 to 40 °C, this value even corresponds to the total error band. Additional measurements and selections can optionally be used to achieve a precision (and also, if calibrated in an accredited test laboratory, an accuracy) of 0,01 %FS. In addition to the digital RS485 interface, the X-line transmitters have a rangeable, analog current or voltage output. Pressure-proof housing – suitable for use in explosive atmospheres.
Request for a quoteSwitzerland
The high-quality CPY20 buffers guarantee pH calibration to ultimate precision. They are produced and bottled in the permanent calibration laboratory that has successfully passed the tough DAkkS accreditation (German accreditation authority). The buffers are specified with an accuracy rating of +/-0.02 pH. They are traceable to NIST and PTB standard reference material and contain only FDA-listed preservatives. Using CPY20 you will achieve correct values that you can rely on.
Request for a quoteDo you sell or make similar products?
Sign up to europages and have your products listed
Results for
Calibration laboratories - Import exportNumber of results
4 ProductsCompany type