• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • sewage pumping station

Results for

Sewage pumping station - Import export

Germany

Verified by Europages

Closed pneumatic-mechanical switching system The sewage-resistant pressure bellows and the end membrane are connected via a pneumatic line routed in a protective tube. There is a plastic housing on the collecting tank of the sewage pumping station which contains 4 easily accessible micro-switches In addition, there is a manometer for continual filling level display located in the housing

Request for a quote

Germany

Verified by Europages

Pressure sensor for analogue filling level measurement Especially suitable for STRATE sewage pumping stations for municipal applications Supply voltage 24 V DC Output of an analogue measuring signal 4 – 20 mA Pressure ranges depending on tank height 0 – 200 or 0 – 400 mbar Safe at several times over-pressure Explosion protection according to ATEX

Request for a quote

Germany

Verified by Europages

The STRATE AWALIFT 80 is the system preferred for draining single- and two-family homes where the drainpipe is below the backwater level (acc. to DIN 1986-100) and the houses cannot be drained using natural gradient. DIN EN 12056-4 specifies the backwater level here as being the road surface of the connection point to the public sewage system. The AWALIFT 80 was specially developed as a small system for building services engineering (max. 12 residents). This means that for the first time, demanding users now have a sewage pumping station available in patented and tried-and-trusted separator technology, which employs polymer components throughout. And the separator system effectively prevents pump blockage. Area of use Single-family homes (e.g. toilet, shower, bath, sink, washing machine etc.) Basement flats Party rooms in the basement Two-family homes etc. Product features Sewage Pumping Station AWALIFT 80 after DIN EN 12056-4 Suitable for faecal wastewater

Request for a quote

Germany

Verified by Europages

Redundant twin measuring system where there is a requirement for increased operational safety for sewage pumping stations (e.g. main pumping station) for municipal applications. Product features The twin measuring system HWAS-BN uses two mutually independent measuring systems which work in different ways. The analogue sensor HWAS for integration in the pump control unit is combined with the pneumatic-mechanical contact sensor system MB. If one of the two measuring systems fails, emergency control is automatically triggered by the other measuring system.

Request for a quote

Germany

Verified by Europages

Redundant twin measuring system where there is a requirement for increased operational safety for sewage pumping stations (e.g. main pumping station) in building service engineering and for municipal applications. Product features The twin measuring system MWAS-BN uses two mutually independent measuring systems which work in different ways. The analogue sensor AS for integration in the pump control unit is combined with the pneumatic-mechanical contact sensor system MB. If one of the two measuring systems fails, emergency control is automatically triggered by the other measuring system.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Verified by Europages

2DFmaster AWAcontrol control system for STRATE sewage pumping stations with two pumps each and an installed overall motor rating of 0.75 kW to 75 kW each. Particularly suitable for building services engineering and municipal applications (twin systems), offers outstanding ease of use and functionality of the AWAmaster technology also for pumping capacities over 4 kW. LCD plain text display Thermal and electrical motor monitoring Manual – 0 – Automatic functions Pump switch-off through switch-off point with run-on time Acknowledgement button Electronic monitoring of the motor current Forced switch-on, switchover and alternation of pumps Internal acoustic alarm Collective fault message potential-free and potential-bound Backwater alarm potential-free All settings and fault messages retained after power failure Operating hours counter High resistance to interference Simple operation Level recorded either by internal pressure transducer, external 4 – 20 mA probe or float switch

Request for a quote

Germany

Verified by Europages

Compact control systems with micro-processor technology for controlling STRATE sewage pumping stations with two pumps each and an installed motor rating of up to 5,5 kW per pump. Particularly suitable for building services engineering (twin systems) and do not require a separate control cabinet. Compact control system AWAmaster 2 in plastic housing Ready for connection with 1.5 m cable and CEE plug 16 A, 5-pole Parallel operation of both pumps to cope with increased sewage volume (e.g. during heavy rain) LCD plain text display Thermal and electrical monitoring of the motors Manual – 0 – Automatic functions Pump switch-off through switch-off point with run-on time Acknowledgement button Electronic monitoring of the motor current Forced switch-on, switchover and alternation of pumps Variable graduated start-up (switch-on delay) Internal acoustic alarm Collective fault message potential-free and potential-bound Backwater alarm potential-free

Request for a quote

Germany

Verified by Europages

The compact control system with micro-processor technology for controlling STRATE sewage pumping stations with one pump and an installed motor rating of up to 5,5 kW. Particularly suitable for building services engineering (single systems) and do not require a separate control cabinet. Compact control system AWAmaster 1 in plastic housing Ready for connection with 1.5 m cable and CEE plug 16 A, 5-pole LCD plain text display Thermal and electrical monitoring of the motor Manual – 0 – Automatic function Pump switch-off through time or switch-off point Acknowledgement button Operating hours counter Ammeter Electronic monitoring of the motor current Forced pump switch-on Variable graduated start-up (switch-on delay) Internal acoustic alarm Collective fault message potential-free and potential-bound Flood alarm potential-free All settings and fault messages retained after power failure (battery back-up not required) Reserve inputs for float switch, telecontrol module

Request for a quote