• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • hazardous

Results for

Hazardous - Import export

Service Provider

Poland

Verified by Europages

WASTE LOGISTICS When ADR is not enough ( … ) To be a versatile partner for our clients, we also offer comprehensive assistance in organizing waste transport EL ROMANO IS AN OFFICIALLY REGISTERED TRANSPORT COMPANY IN THE BDO SYSTEM BDO | Database of Products and Packaging and Waste Management It is enough for us that you provide the waste code and we will help in all documentation and of course transporting the material EL ROMANO will have a base of over 200 classified waste that it can legally transport throughout Europe! We invite You to Cooperation !

Request for a quote

Switzerland

Material Safety Data Sheet - Hazardous Substances Advice and Hazardous Substance Management Overview of our services: - Check of conformity and plausibility as well as updating of existing Material Safety Data Sheets - Preparing of extended Material Safety Data Sheets - Classification and labelling of substances according to the current GHS regulation (CLP regulation) Depend on requirements INVITRO-CONNECT GmbH checks whether your existing safety data sheets are still compliant and plausible to follow latest REACH guidelines and if necessary, updates them for you. Furthermore, based on our know-how we provide extended material safety data sheet, following the REACH Directive as well as the latest European GHS regulation for classification and labelling of substances. INVITRO-CONNECT GmbH - Fast Project Execution: personal - competent - reliable --> contact@invitro-connect.com Best regards Pascal Piller and Dr. Ute Hassmann and the whole team of INVITRO-CONNECT GmbH

Request for a quote

Switzerland

Material Safety Data Sheet - Hazardous Substances Advice and Hazardous Substance Management Overview of our services: - Check of conformity and plausibility as well as updating of existing Material Safety Data Sheets - Preparing of extended Material Safety Data Sheets - Classification and labelling of substances according to the current GHS regulation (CLP regulation) Depend on requirements INVITRO-CONNECT GmbH checks whether your existing safety data sheets are still compliant and plausible to follow latest REACH guidelines and if necessary, updates them for you. Furthermore, based on our know-how we provide extended material safety data sheet, following the REACH Directive as well as the latest European GHS regulation for classification and labelling of substances. INVITRO-CONNECT GmbH - Fast Project Execution: personal - competent - reliable --> contact@invitro-connect.com Best regards Pascal Piller and Dr. Ute Hassmann and the whole team of INVITRO-CONNECT GmbH

Request for a quote

Switzerland

INVITRO-CONNECT GmbH offers various test strategies without animal testing for examining Eye Irritation / Eye damage hazard assessment. From standard regulatory hazard assessments to providing information on the degree of ocular irritation, to discriminating among extremely mild eye area products, INVITRO-CONNECT’ Study Monitors take the time to understand your specific goals and apply the most relevant, cost-effective strategies to achieve them. Tests for Eye Irritation / Eye damage hazard assessment in vitro: HET-CAM Assay BCOP: OECD 437 Isolated Chicken Eye Test: OECD 438 STE / Short Time Exposure (STE, OECD 491): Ocular Irritection EpiOcular & SkinEthic HCE Reconstructed human Cornea-like Epithelium (RhCE): OECD 492 For more information please contact INVITRO-CONNECT GmbH for assistance in developing specialized protocols for your test materials. INVITRO-CONNECT GmbH: Fast Project Execution: personal - competent - reliable --> contact@invitro-connect.com

Request for a quote

Switzerland

INVITRO-CONNECT GmbH offers various test strategies without animal testing for examining Eye Irritation / Eye damage hazard assessment. From standard regulatory hazard assessments to providing information on the degree of ocular irritation, to discriminating among extremely mild eye area products, INVITRO-CONNECT’ Study Monitors take the time to understand your specific goals and apply the most relevant, cost-effective strategies to achieve them. Tests for Eye Irritation / Eye damage hazard assessment in vitro: HET-CAM Assay BCOP: OECD 437 Isolated Chicken Eye Test: OECD 438 STE / Short Time Exposure (STE, OECD 491): Ocular Irritection EpiOcular & SkinEthic HCE Reconstructed human Cornea-like Epithelium (RhCE): OECD 492 For more information please contact INVITRO-CONNECT GmbH for assistance in developing specialized protocols for your test materials. INVITRO-CONNECT GmbH: Fast Project Execution: personal - competent - reliable --> contact@invitro-connect.com

Request for a quote

Switzerland

Determination of skin sensitization potential is a critical endpoint in the safety assessment of raw materials, chemicals, mixtures and formulations. Although the Guinea Pig Maximization Test (GPMT) and Local Lymph node assay (LLNA) have historically been used to address this adverse effect, in vitro assays have been developed and validated in order to replace these resource-intensive animal tests. INVITRO-CONNECT GmbH offers various test strategies without animal testing for examining skin sensitization: - Direct Peptide Reactivity Activation Assay (DPRA, OECD 442C) - ARE-Nrf2 Luciferase Keratinocyte Activation Test Method (OECD 442D) -Human Cell Line Activation Test (h-CLAT, OECD 442E) -Kinetic Direct Peptide Reactivity Assay (kDPRA) -Myeloid U937 Skin Sensitization Test (MUSST / U-SENS) -and more Fast Project Execution: personal - competent - reliable --> contact@invitro-connect. - More than 80 Test Laboratories - Product Safety - Regulatory Service -

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Low cost solution for multi-access applications Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 420 years Max. activation distance: 9 mm, 1 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.4A max / 24V redundant and 1 x 250mA PNP contact Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 or INOX 316L mirror polished (ref. + OX) Electrical Connection: 3, 6, 12m cable (UL2464 PVC) or 50cm cord with M12 connector (UL20549 PUR) (ref. + MKT) Water resistance: IP 67/68 or IP 69K stainless steel version (requires cable input protection) Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Suitable for groove profiles and single or double doors Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 334 years Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.8A max/24V redundant / 1xNF (78S) or 1 x NO (98S) 250mA Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4). Suitable for grooved profiles. Screw caps provided. Mounting position: 1 Material: Polycarbonate Electrical connection: 2 M12 metal bases for instant serial connection Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: screen printed + serial no. for traceability

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Suitable for groove profiles and single or double doors Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 8 mm, 3 mm hysteresis Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 1 x PNP 250mA (X5) or 1xNF (X5.2) auxiliary Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic (SR version) or Manual (AR version) Attachment: 4 tamper-proof M4 screws (optional ref: BH4). Suitable for grooved profiles. Screw caps provided. Mounting position: 1 Material: Polycarbonate Electrical connection: 1 M12 connector (X5 version) or 2 M12 connectors (X5.2 version for instant serial connection) Water resistance: IP 67/68 Temperature: -25°C to +60°C Marking: screen printed + serial no. for traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller Low cost solution for multi-access applications • Level of performance with AWAX controller: up to PL = e • Safety category: up to 4 with an AWAX controller • Time before dangerous failure: MTTFd = 334 years • Max. activation distance: 10 mm, 2 mm hysteresis • Safety contacts/diagnostics: 2 x NO 0.8A max / redundant 24V / 1xcontact PNP 250mA • Detection encoding: mono-code inviolable • Indicator: LED indicates code recognition • Reset: automatic • Attachment: 4 tamper-proof M4 screws (optional ref: BH4) • Mounting position: 78S-98S, 78SMKT, 78SMKT130 versions: 2 (double wall brackets) • Mounting position: 78SM12 and 98SM12 versions: 1 • Material: 78S-98S, 78SMKT, 78SMKT130: PA6 or INOX316L (ANATOM78S-OX or ANATOM78S-OX-MKT) • Matierial for 78SM12, 78SESM12 and 98SM12 : polycarbonate (PC) • Electrical Connection: 3, 6, 12m cable (78S/98S) or 50cm cord with M12 connector (ref. + MKT) or 130cm cord with M12 connector (ref. + MKT130) or M12 metal (ref. + M12) • Water resistance: IP 67/68 (PA6, PC) or IP 69K with stainless steel - new generation • Temperature: -25°C to +60°C • Marking: PA6 pad printing + serial no., PC pad printing + serial no., INOX316L laser engraving with mechanically punched serial no. for permanent traceability • Certification: UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209) (Not applicable for versions MKT and M12)

Request for a quote

France

Contactless encoded electronic sensor with relay Up to 8 zone differentiation codes Safety contacts 2A / 250V • Level of performance without an external controller: PL = c • Level of performance with AWAX controller: up to PL = e • Safety category without an external controller: 1 • Cycle before dangerous failure: B10d = 2,000,000 at 2A • Max. activation distance 3SSR24V/5SSR24BX/5SSR24BX-US: 8 mm, 2 mm hysteresis • Max. activation distance 2SSR24V/2SSR24BX: 4 mm, 2 mm hysteresis • Safety contacts/diagnostics 3SSR24V: 1 x NO 2A/250V / 1 x NF 2A/250V auxiliary • Security contacts/diagnostics 5SSR24BX and 5SSR24BX-US: 2 x NO 2A/250V / 1 x PNP NF 250mA auxiliary (24V) • Security contacts 2SSR24V: 2 x NO 2A/250V • Security contacts 2SSR24BX: 1 x NO 2A/250V and 1 x NF 2A/250V • Detection encoding 3SSR24V, 5SSR24BX/5SSR24BX-US: single inviolable code • Detection encoding 2SSR24V and 2SSR24BX: 8 inviolable codes • Indicators 2SSR24V, 2SSR24BX, 3SSR24V and 5SSR24BX: Red LED indicating code absence (not transmitter) • Indicator 5SSR24BX-US: Two-color red/green LED • Reset: automatic • Attachment: 4 tamper-proof M4 screws (optional ref: BH4) • Mounting position: 2 (double wall brackets) • Matierial PA6: 2SSR24V, 2SSR24BX, 3SSR24V, 5SSR24BX, 5SSR24BX-MKT and 5SSR24BX-US • Material INOX 316L mirror polished: 5SSR24BX-OX and 5SSR24BX-OX-MKT • Electrical Connection: 3, 6, 12m cable or 50cm cord with M12 connector (UL20549 PUR) for5SSR24BX-OX and 5SSR24BX-OX-MKT • Water resistance: IP 67/68 (PA6) or IP 69Kwith stainless steel - new generation • Temperature: -25°C to +60°C • Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability

Request for a quote

France

Contactless coded electronic sensor Connectors / Wiring compatible with most hardware Suitable for grooved profiles Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 8 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 0.8A/24V redundant and 1 x 250mA PNP contact Detection encoding: mono-code inviolable Indicator: 1 LED indicating code recognition and 1 LED indicating code absence Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4). Suitable for grooved profiles. Screw caps provided. Mounting position: 1 Material: INOX 316L mirror polished Electrical connection: 2 x 50cm cords with M12 connector Water resistance: IP 69K Temperature: -30°C to +70°C. Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

Contactless coded electronic sensor Total safety management with an AWAX controller High temperature Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with an AWAX controller Time before dangerous failure: MTTFd = 100 years Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 1A/24V redundant and 1 x 250mA PNP contact Detection encoding: mono-code inviolable Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: INOX 316L mirror polished Electrical connection: 50cm Ultra-soft silicone cord with M12 connector. Water resistance: IP 69K Extreme temperature: -40°C to +125°C Protective cover 316L stainless steel mirror polished "ref. + C" option Marking: laser engraving with mechanical punching of the serial number for permanent traceability

Request for a quote

France

Manages person entry in hazard zones using an electrical locking key Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Electrical locking key with position contact Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle before dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 2xPNP 250mA auxiliary (open/closed door and locking/unlocking of contacts) Detection encoding: mono-code inviolable Note: two-color LED indicates the key locking position; white LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: Polycarbonate Electrical connection: M12 metal base Water resistance: IP 65 Temperature: -15°C to +60°C Marking: screen printed + serial no. for traceability

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 50mA Max. activation distance: 10 mm, 2 mm hysteresis Safety contacts: 2 x NO 250 mA/48V redundant Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M3 screws (optional ref: BH3) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) Water resistance: IP 67/68 Temperature: -20°C to +60°C Marking: pad printing + serial no. for traceability

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications Level of performance without an external controller: PL = d Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 Safety Integrity Level: SIL 2 Cycle after dangerous failure: B10d = 2,000,000 at 2A Max. activation distance: 10 mm, 2 mm hysteresis Security contacts / diagnostics AMX5 / AMX5CM12: 2 x NO 2A / 48V redundant / 1 x PNP 250mA auxiliary Security contacts AMX4: 2 x NO 2A/48V redundant Security contacts / diagnostics AMX3: 1xNO 2A / 48V redundant (2 series contacts) / 1xNF 250mA auxiliary Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 or INOX 316L mirror polished (AMX3-OX/AMX5-OX ⇥or PC (AMX5CM12) Electrical Connection: 3, 6, 12m (UL2464 PVC) or 50cm cable with M12 connector (UL20549 PUR) (ref + MKT) or M12 metal base (AMX5CM12) Water resistance: IP 67/68 (PA6 / PC) or IP 69K with stainless steel - new generation Temperature: -25°C to +60°C Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability Certification: TÜV Rheinland 01/205/5238/12 License Test Mark 968/EL 214.01/12 UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209)

Request for a quote

France

Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller Level of performance without an external controller: PL = c Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 1 Cycle before dangerous failure: B10d = 2,000,000 at 100mA Max. activation distance: 6 mm, 2 mm hysteresis Safety contacts/diagnostics: 2 x NO 1A/48V redundant / 1 x PNP 1A auxiliary Detection encoding: mono-code inviolable Indication: LED indicating code absence Reset: automatic Attachment: 2 M30 nuts provided Mounting position: 1 Material: CuNi Electrical connection: 3, 6, 12m cable Water resistance: IP 67 Temperature: -25°C to +60°C Marking: label + serial no. for traceability

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Slovenia

Choose your perfect combination with part-load (LTL), full-load (FTL) or collector, and choose from different types of waste or hazardous materials (ADR) transport.

Request for a quote

Russia

Hazardous cargo is cargo that may harm the health or life of people and/or the environment during transportation. Transportation of hazardous cargo involves the use of various types of transport: air, land and sea transport . When transporting hazardous cargo as part of a groupage cargo, it is necessary to comply with certain standards of compatibility of various classes with each other. Hazardous cargo delivery is carried out in accordance with the regulatory documents governing certain activities related to this type of transportation, as well as the requirements for the vehicle. The hazardous cargo requires mandatory labeling in accordance with the hazard level. Taking into account all the features of cargo related to the hazardous category, the Noord Connect Company will choose the favorable delivery method, while ensuring the required level of security.

Request for a quote

Russia

Machines and (or) equipment including those used at hazardous industrial facilities, for which types of hazard have been detected and identified, the requirements for elimination and reduction of which are set out according to the Annexes № 1 and № 2 to the regulations. Annexes № 1 and № 2 to the regulations contain basic and supplementary safety requirements for machines and equipment. Used machines and (or) equipment, or those produced for own manufacturers’ needs Component and spare parts to machines used for repair (maintenance) of machines and (or) equipment Machines and (or) equipment meant to maintain integrity and stability of communication networks performance and use of RF spectrum Machines and (or) equipment used for medical purposes and used in direct contact with a patient (Xray, diagnostic, therapeutic, orthopedic, dental, surgical equipment) Machines and (or) equipment specially designed for nuclear energy use area.

Request for a quote

Belarus

ADR transportation requires special training and certification and can be costly to companies that do not follow strict European requirements. PRIMUM ensures ADR transportation in accordance with all European requirements and standards. Our drivers are properly trained and certified. SQAS certified. Our certification allows us to transport the following ADR loads: Сlass 2 — compressed, liquefied and dissolved gases under pressure; Сlass 3 — flammable liquids; Сlass 4.1 — flammable solids; Сlass 4.2 — substances liable to spontaneous combustion; Сlass 4.3 — substances that emit flammable gases in contact with water; Сlass 5.1 — oxidizing substances; Сlass 5.2 — organic peroxides; Сlass 6.1 — toxic substances; Сlass 6.2 — infectious substances; Сlass 8 — corrosives; Сlass 9 — miscellaneous dangerous substances.

Request for a quote

United Kingdom

Waste management services across the UK - including recycling, preparation for re-use, shredding and TFS

Request for a quote