• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • automatic switches

Results for

Automatic switches - Import export

Service Provider

France

Verified by Europages

If you want to carry out redundancy tests to check your installations, we advise you to rent this ATS (Automatic Transfer Switch) box in addition to your load bank. This will allow you to switch the electrical load between channel A and channel B without having to disconnect and reconnect the cables.

Request for a quote

Russia

We bring to your attention a device for remote power control of data center equipment Resilient Power Control Module (RPCM). RPCM combines the functions of remote power management, automatic transfer switch (ATS) without interrupting the operation of connected equipment, short circuit protection and an electricity meter on each output. RPCM has 2 power inputs and 10 pins. The device has no analogues on the market.

Request for a quote

Greece

Power: 1800W, AC 220-240V, 50/60 HZ Digital Easy Touch Panel Control with LED Display Big Size Capacity with Light: Internal Light to check cooking, 12 L Capacity Multifunction: With 90 minutes Timer and 12 Cooking Presets Temperature Control up to 200o and rapid airflow circulation Automatic switch off function Package includes: 1x Drip Tray 3x Mesh Trays 1x Rotisserie Fetch Tools 1x Rotisserie Split 1x Round Basket 8x Skewers 2x Adjustable Skewer Racks 1x Square Basket 1x Manual

Request for a quote

France

Atex and machine safety management in a compact 45 mm format Atex dual-channel insulation barrier and controller for built-in machinery safety Atex safety ATEX standards EN 60079-0 EN 60079-11 EN 60079-25 EN 60079-26 ATEX marking [Ex ia] IIC Ga [Ex ia] IIIC Da II(1)GD Product used in combination with the "ANATOM78S- (PL or OX)-EEX" sensor Machine Safety Performance level with AWAX controller: PL = e in accordance with ISO 13849-1 Safety category: 4 in accordance with ISO 13849-1 Time before dangerous failure: MTTFd = 120 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting. Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant parallel Indicators: 3 LEDs Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +40°C. Certification: INERIS 06ATEX0007X

Request for a quote

France

Safety management in 2 zones in a compact 45 mm format Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics zone 1: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Safety contacts/diagnostics zone 2: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant series Indicators: 2 display LEDs per zone for diagnostics and 1 LED for power Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C Certification: TÜV Rheinland 01/205/5168/11

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

France

Safety management in a compact 22.5 mm format Mono or two-channel with wiring. "Low consumption" Inputs Removable terminals Performance level with AWAX controller: PL = d Safety category: 3 (two-channel) Safety Integrity Level: SIL 2 Time before dangerous failure: MTTFd = 240 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Safety contacts/diagnostics: 2x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant + 1x NO static 400 mA Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

France

Safety management with 85~265 VAC power Short-circuit detection in 2 µs, self-resetting Removable terminals Performance level with AWAX controller: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Time before dangerous failure: MTTFd = 415 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts) Reaction 2 µs ultrafast Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant Indicators: 3 LEDs for diagnostics Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +60°C

Request for a quote

Russia

This floating fountain is easy to install and does not require construction works. Its compact size makes it easy to install in a pond - just connect the device to the control panel. The fountain provides aeration of the water, prevents the growth of algae. Additional options (such as lighting) are not included in the set. They can be ordered separately. The fountain is equipped with a valve that allows you to change the jets heights manually. In order to automatically change the jets heights, the fountain can be connected to a frequency converter (additional option). Automatic switching on and off of the fountain and lighting (not included) is performed by the Siemens controller. Equipment: 1. Floating module made of stainless steel 2. Pump in a stainless steel filter casing 3. Fountain nozzle 4. 8 pins for fixing the lighting fixtures 5. Underwater cable - 50 m. 6. 4 concrete anchors in a polymer sheath, rope, carabiners. 7. Weatherproof fountain control cabinet, IP66.

Request for a quote