• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • construction products

Results for

Construction products - Import export

PolandWarsaw and the region of MazoviaManufacturer/producer

Poland

Verified by Europages

The FDA12 round fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification f construction products and building elements). The fire resistance was tested as per PNEN 136622001P (Fire resistance tests for service installations Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA12 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal diameter sizes DN100, DN125, DN160, DN200, DN250, and DN315. All fire dampers have a pull spring control gear and a fusible thermal trip (in FDA12T) or a returnspring actuator coupled with a thermal trip (in FDA12M).

Request for a quote

Poland

Verified by Europages

The FDA12 round fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification f construction products and building elements). The fire resistance was tested as per PNEN 136622001P (Fire resistance tests for service installations Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA12 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal diameter sizes DN100, DN125, DN160, DN200, DN250, and DN315. All fire dampers have a pull spring control gear and a fusible thermal trip (in FDA12T) or a returnspring actuator coupled with a thermal trip (in FDA12M).

Request for a quote

Poland

Verified by Europages

The FDA212 round fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification of construction products and building elements). The fire resistance was tested as per PNEN 1366 22015 (Fire resistance tests for service installations — Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA212 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal diameter sizes DN200, DN224, DN250, DN280, DN300, DN315, DN355, DN400, DN450, DN500, DN560, DN600, DN630.

Request for a quote

Poland

Verified by Europages

The FDA212 round fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification of construction products and building elements). The fire resistance was tested as per PNEN 1366 22015 (Fire resistance tests for service installations — Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA212 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal diameter sizes DN200, DN224, DN250, DN280, DN300, DN315, DN355, DN400, DN450, DN500, DN560, DN600, DN630. All fire dampers have a torsion spring trip (in FDA212T) or a returnspring actuator coupled with a thermal trip (in FDA212M).

Request for a quote

Poland

Verified by Europages

The FDA212 square fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification of construction products and building elements). The fire resistance was tested as per PNEN 1366 22015 (Fire resistance tests for service installations — Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA212 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal sizes 160x160 – 1000x500 mm. All fire dampers have a torsion spring trip (in FDA212T) or a returnspring actuator coupled with a thermal trip (in FDA212M).

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Poland

Verified by Europages

Round ventilation duct made of expanded polypropylene (EPP). The most important features of the product are rigid construction, low weight, easy assembly (integrated malefemale coupling) and good thermal insulation. EPP ducts, used, for example, as sections of the supply and exhaust ventilation systems with heat recovery, do not require additional insulation. The system eliminates the formation of thermal bridges. Lenght EPP ducts 1 m sections Diameters 125, 160 and 200 mm. Wall thickness 15 mm Thermal conductivity 0.039 W / m*K Airtightness class ATC2 (old D) @ 90Pa acc. to PNEN 17192201901

Request for a quote
Filters

Results for

Construction products - Import export

Number of results

7 Products