• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • generator systems

Results for

Generator systems - Import export

PolandManufacturer/producer

Poland

Verified by Europages

The Preservatech Mini One is a miniature humidity control device for museum showcases and storage enclosures. This robust and extremely efficient unit can reliably control humidity in individual or multiple enclosures. The Mini One active microclimate generator is a sixth generation system, satisfying the demanding standards of preventive conservation and modern museum design. It incorporates the most recent developments in electronic humidity control, noise suppression, and pollution abatement — built on the heritage of a family of microclimate control devices extending back to 1978. This positive pressure microclimate control system will typically maintain the relative humidity level in a sealed museum enclosure to within two percent (or less) of your target relative humidity. Depending upon the ambient temperature conditions and enclosure construction, relative humidity levels of less than thirty-five to over eighty percent can be attained.

Request for a quote

Poland

Verified by Europages

The FDA212 square fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification of construction products and building elements). The fire resistance was tested as per PNEN 1366 22015 (Fire resistance tests for service installations — Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA212 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal sizes 160x160 – 1000x500 mm. All fire dampers have a torsion spring trip (in FDA212T) or a returnspring actuator coupled with a thermal trip (in FDA212M).

Request for a quote

Poland

Verified by Europages

The FDA12 round fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification f construction products and building elements). The fire resistance was tested as per PNEN 136622001P (Fire resistance tests for service installations Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA12 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal diameter sizes DN100, DN125, DN160, DN200, DN250, and DN315. All fire dampers have a pull spring control gear and a fusible thermal trip (in FDA12T) or a returnspring actuator coupled with a thermal trip (in FDA12M).

Request for a quote

Poland

Verified by Europages

The FDA12 round fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification f construction products and building elements). The fire resistance was tested as per PNEN 136622001P (Fire resistance tests for service installations Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA12 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal diameter sizes DN100, DN125, DN160, DN200, DN250, and DN315. All fire dampers have a pull spring control gear and a fusible thermal trip (in FDA12T) or a returnspring actuator coupled with a thermal trip (in FDA12M).

Request for a quote

Poland

Verified by Europages

The FDA212 round fire dampers are designed for use in general ventilation systems to seal off smoke and fire between adjacent fire partitions. The fire dampers are classified according to EN 135013+A12010P (Fire classification of construction products and building elements). The fire resistance was tested as per PNEN 1366 22015 (Fire resistance tests for service installations — Part 2 Fire dampers). The entire manufacturing process meets the requirements of EN 156502010. The FDA212 fire dampers can be installed in horizontal and vertical fire partitions to provide fire resistance of EI 120 (ve ho i↔o) S (which may depend on the actual fire resistance of the partition). The fire dampers are available in the nominal diameter sizes DN200, DN224, DN250, DN280, DN300, DN315, DN355, DN400, DN450, DN500, DN560, DN600, DN630.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Poland

The FORD FDT9200SE power generator is a professional tool that will provide you with an independent power source in places without access to electricity. With an efficient 6kW diesel engine and a modern control panel, the FORD FDT9200SE is ideal for commercial applications, construction sites, companies, as well as home or office emergency protection. Control panel allows you to precisely monitor power, control voltage and current, as well as provides protection against overload, overheating and a low oil shutdown system. The generator is equipped with a convenient electric starter and an automatic starter for emergency operation with the use of ATS backup power. Product compliant with EURO 5 and EC: 2006/42/EC Machinery Directive 2006/95/EC Low Voltage Directive, 2000/14/EC & 2005/88/EC NOISE DIRECTIVE, DLGS 262/02 Applicable harmonized standards: DIN 6280-10, EN 50082-1, CISPR, EN ISO 3744:1995 AND ISO 8528-10:1998