• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • master communication

Results for

Master communication - Import export

China

It's very popular that our pressure and temperature measurement transmitters in oil and gas market , and HART modem is essential basic equipment. For some customers who want to connect two different industrial networks, we provide a cost-saving solution that gateways equipment. It basically realizes full communication, for Modbus, HART, Profibus, FF and DP. G0310 Modbus to HART Gateway, designed by Microcyber Corporation is a gateway device for Modbus-RTU protocol and HART protocol. As Modbus master, G0310 Modbus to HART Gateway communicates with devices that have Modbus-RTU communication function via RS485 interface. It can convert device data to HART device variables output, and it also supports 4~20mAcurrent output. Connect different control systems (Siemens, Emerson, Schneider Electronics, ABB, Yokogawa, Rockwell, etc.)

Request for a quote

Germany

The ESX-3IOS is a CAN-I/O module for the extension of the inputs/outputs of a master control unit via CAN. The communication with the master control unit takes place via CANopen, CANopen Safety, the STW protocol ECeS and J1939. The ESX-3IOS fulfills the safety requirements laid down in SIL 2 and PL d. For safe communication, the CANopen safety protocol and ECeS are supported. In addition to the Wake-up via terminal 15 / D+, Wake-up can also be carried out via CAN. Due to the robust aluminum die cast housing, a total current of up to 12 A can be implemented. The ESX-3IOS has over 16 inputs and 15 outputs.

Request for a quote

Germany

Features - Configuration and management of EtherCAT networks - Cyclic exchange of process data - Sophisticated API common to all implementations as interface between the application and the EtherCAT Master Stack - Mailbox based communication with: CAN application protocol over EtherCAT (CoE) Ethernet over EtherCAT (EoE) File over EtherCAT (FoE) Servo Drive over EtherCAT (SoE) - Built-in detailed diagnostics and profiling functions - Written in ANSI-C designed with high performance, small resource usage and scalability in mind - The core components are operating system (OS) and CPU architecture independent - Adaption to many prevalent (real-time) operating systems available from stock - EtherCAT Master Class A according to ETG.1500 esd electronics is a member of the EtherCAT Technology Group (ETG).

Request for a quote

Poland

Suitable for a manual operation by operator, Suitable for an automatic cell with a robot load/unload, Suitable for an automatic conveyor production, Wheel presence sensors, Imbalance compensation of a spindle, Ergonomic size of the machine, Sophisticated fluids drain system with reservoir, Spindle protection system from metal chips, Automatic clamping of a wheel hub with a heavy duty pneumatic clamping chuck, Automatic brake and wheel positioning, Fastest balancing cycle time, Fastest tool changeover time, Made of wellknown brands heavy duty components, Servomotor as a spindle drive motor, Software capabilities Valve compensation feature, The best quality, automatic display, Password protection access for operator and shift manager, Any language possible, Industry 4.0 compliant, Static and dynamic imbalance display, Autotest and selfcalibration, Data transfer and communication with master station, CSV file data creation Sophisticated remote diagnostic and support software .

Request for a quote

Turkey

The system visually stimulates the driver in various weather conditions (fog, rain, snow) by warning the drivers of highway speeds and the driver can observe snow and ice during the winter season, to improve their driving safety and comfort by facilitating transportation. One of the most important features that distinguish the GPS based Synchronous Flasher from its counterparts is that it does not lose synchronization without the need for a master device because it is GPS based. The flasher devices, which can not be GPS-based, have a Master device and devices that are in slave mode to provide synchronization. The disadvantage of this is that all devices lose synchronization if the master device interrupts communication with other devices due to a situation or if it fails. Since there is no master-slave mode in GPS-Based Solar Flasher products, it is a great advantage to continue to work without any other communication breakdown or failure in case of failure of other devices.

Request for a quote

Italy

The Ekinex® gateways are modular KNX devices for panel mounting. The Gateway range includes: Modbus, which are devices that allow an exchange of information between one or more slave devices communicating on a RS485 differential serial network or by Ethernet through Modbus protocol; BACnet, which allow an exchange of information with a master device communicating on a RS485 differential serial network or by Ethernet through BACnet protocol; DMX, which allow an exchange of information between one or more slave devices communicating on a RS485 differential serial network or by Ethernet through DMX protocol; M-bus, which allow an exchange of information between one or more slave devices communicating through M-bus protocol; Profinet, which allow an exchange of information with a master device communicating by Ethernet through Profinet protocol; DALI, which allow an exchange of information between one or more slave devices communicating through DALI protocol.

Request for a quote