• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • technical gas

Results for

Technical gas - Import export

Manufacturer/producer

Malta

Verified by Europages

When it comes to technical gas, this is mainly used in the industrial market. This type of nitrous oxide (N2O) is less pure. It is also called impure gas and therefore the price of this type is also cheaper. Gas has a purity level. The purity level of technical nitrous oxide is 98%. The reason this gas is impure is that no filter is applied here to make the nitrous oxide purer. What also differs is that this type of nitrous oxide (N2O) bottle does not have a residual pressure valve. This residual pressure valve can ensure and prevent rust, dirt, or other particles that should not be in the bottle from entering the bottle. What technical nitrous oxide (N2O) can be used for is, for example, as an oxidizer in a rocket engine. The advantage of this is that it is then nontoxic, also because nitrous oxide (N2O) is much easier to store and it is stable at room temperature. Technical nitrous oxide (N2O) is therefore also widely used in the aerospace industry.

Request for a quote

Germany

Verified by Europages

ATMOSPHERIC PRESSURE, MAINTENANCE FREE AND PROTECTED AGAINST EXTERNAL EFFECTS The pressureless gas storage system of Lipp is used for the storage of gas produced on landfill sites, waste water treatment plants and also as external storage on biogas plants. The system is determined by its robust and technical advanced construction where the gas balloon is protected by a galvanized steel tank. This protects the balloon against UV light and also other external factors. The system is mostly utilized at landfill sites or WWTP to buffer the gas before its further processing. The experience gained during the past decades has improved the complete system and the single components and makes it a perfect choice for end users and general contractors.

Request for a quote

Italy

Verified by Europages

VERTICAL VACUUM SEALING MACHINE FOR BAGS - ALSO WITH MAP GAS INLET The sealers mod. DZQ 600 LS/DZQ 800 LS are multifunctional machines suitable for sealing and vacuum packing large bags and sacks, also in MAP (with technical gas injection). The vacuum pump of 20 mc./h. it minimizes air intake times and the machines are equipped with valves for the injection of inert gas for packaging in a modified atmosphere. The double sealing bars with a width of 10 mm. and compressed air closure ensure perfect sealing on any type of material, even of high thickness. The bars are closed by means of a double button command (dual safety control). The sack support surface is adjustable. Thickness max. bag mm. 0.20 (0.8 total with bellows) By means of selectors and potentiometers it is possible to set the "sealing", "empty time" and "gas injection time" functions. The machine is equipped with two nozzles which, when the vacuum option is activated, descend into the bag and perform suction.

Request for a quote

Austria

Verified by Europages

Modern and large biogas systems for biogas upgrading to natural gas quality is becoming ever more popular. Here the biogas is treated for the complete removal of all unwanted gaseous materials and fed into the gas network or alternatively used as fuel in vehicles. Here the technical requirements of the gas flare become even more critical, as the flare is now not only to be suitable for use with pure biogas, but also must be compatible with biomethane with a methane content of > 95%. This is no problem for our modern NOXmatic BM flare for biogas and biomethane. With flexible burner technology we can combust both materials safely, efficiently and with low emissions. The broad range of accessories for the NOXmatic standard flare is also available to our customers. With this offering we are able to meet all the individual requirements of our customers and their applications.

Germany

Verified by Europages

Explosionproof/flameproof gas preheater EEx d -ATEX und IECEx zertifiziert In general a cooling down takes place at expansion of gases whilst a heating takes place at compression. Typical gases are carbon monoxide, natural gas and air. The temperature change, which occurs at expansion of gas or gas mixture from a high to low pressure i.e. after a gas pressure control is called Joule-Thomson effect. In order to prevent the effects of Joule-Thomson as icing or condensate separation, the gas will be heated up before expansion. The gas pre heaters are suitable for all kind of gaseous media (i.e. air, natural gas, technical gases, fuel gas) and low flow process applications, suitable for pressures up to 300 bar. The “Cast electric heaters” type flameproof electrical gas pre heaters are certified for use in zone 1 or 2 hazardous area, custom built to meet client specification. The gas pre heater consists of a process tube coil and an electrical heating bundle, casted in aluminium. The process gas flows through the tube coil and is heated by the aluminium block that provides the heat transfer. This indirect electric heating gives an accurate control of the process and eliminates pressure vessel design and associated costs.

Request for a quote

Germany

Verified by Europages

Customized air-water heat exchangers for industrial use Three types of air-water heat exchangers Three different designs o air-water heat exchangers The Anthermo GmbH delivers three different designs of air-water heat exchangers: Finned tube heat exchangers Lamella heat exchangers Straight tube heat exchangers These heat exchangers are designed in a way, that inside the tube water or another liquid circulates. The air flows around outside the tubes or the fins/lamellas. The connection between the fins and the tube is used to enlarge the space for heat transfer between the liquid and the gas fluid. The technical figures (for ex. amount of air, temperature, pressure, waste of air) can be different for the air-water heat exchanger. Also the operating conditions and the environment conditions can vary from application to application.

Request for a quote

Turkey

Verified by Europages

NEDEX insulating glass secondary sealant ARCOL is a 2-component, solvent-free adhesive/sealant with SH-bonding ends (polysulfite). The rheological properties of the product make it suitable for manual and robot processing. ARCOL adheres to glass, aluminium, galvanized steel and stainless steel without the use of primer. For other products, such as coated glass, glass from which the coating has been removed, treated spacer profiles or profiles made of other materials; relevant trials must be carried out to ensure the product's suitability. The use with polycarbonate or polymethyl methacrylate (PMMA) is not recommended. It is produced only for insulated glass manufacturing. For different applications please contact NEDEX Technical Department. Very low gas and moisture penetration rates High adhesion to aluminium and glass surfaces Long potlife times and Short curing times are the most important characteristics. Packaging: Box kit (15 lt A + 1,5 lt B / 16,5 lt A + 1,8 lt B)

Request for a quote

Turkey

Verified by Europages

NEDEX insulating glass secondary sealant PS-002 is a 2-component, solvent-free adhesive/sealant with SH-bonding ends (polysulfite). The rheological properties of the product make it suitable for manual and robot processing. PS-002 adheres to glass, aluminium, galvanized steel and stainless steel without the use of primer. For other products, such as coated glass, glass from which the coating has been removed, treated spacer profiles or profiles made of other materials; relevant trials must be carried out to ensure the product's suitability. The use with polycarbonate or polymethyl methacrylate (PMMA) is not recommended. It is produced only for insulated glass manufacturing. For different applications please contact NEDEX Technical Department. Very low gas and moisture penetration rates High adhesion to aluminium and glass surfaces Long potlife times and Short curing times

Request for a quote

Slovenia

Magnetic differential manometer MDM 40 is designed to indicate pressure drop across the filter element in compressed air system. For any other technical gas please contact us or your local distributor. It detects when the filter cartridge is clogged and should be replaced. MDM 40 is typically installed on the head of the filter housing. MDM40 can be used in variety of applications.

Request for a quote

Slovenia

AOK16B is designed for fully automatic discharging of condensate or any other non aggressive fluid from compressed air system. For any other technical gas please contact us or your local distributor. AOK16B is easy to install inside to the filter housing. AOK16B can be used in a variety of applications. For applications not listed please contact us or your local distributor.

Request for a quote

Slovenia

We are a producer of custom made pressure vessels according to PED or ASME standards. Pressure vessels are tanks, designed to store compressed air. Pressure vessels can also be designed for any other technical gas. Volume of pressure vessel depends on compressor capacity and on consumption of compressed air. Each of our pressure vessels is calculated, assembled, tested and guaranteed to conform standards and to withstand the process necessary for your application.

Request for a quote

Slovenia

AOK20 SS is designed for fully automatic discharging of condensate or any other non aggressive fluid from compressed air system. For any other technical gas please contact us or your local distributor. The unit can be installed as external drain on any application specified below. Condensate accumulates in the stainless steel reservoir and when the level is high enough the condensate is discharged from the system without any air loss. A direct acting valve is operated by a precise level controlled floater which assures reliable and efficient operation. Thanks to its robust stainless steel housing AOK20 SS is suitable for heavy duty applications. On the front, the AOK20 SS, is also equipped with a separate manual drain for venting.

Request for a quote

Slovenia

Automatic mechanical condensate drain AOK 13PA has been developed for fully automatic discharging of condensate or any other non-aggressive fluid from compressed air system. The unit can be installed as external drain on any application specified below. Condensate accumulates in reservoir and when the level is high enough condensate is being discharged from the system without any air losses. Direct acting valve is operated by precise level-controlled floater which assures reliable and efficient operation. For any other technical gas please contact us or your local dealer. Automatic mechanical condensate drain AOK 13PA can be used in variety of applications. For applications not listed please contact us or your local dealer.

Request for a quote

Slovenia

PF process filters are designed for applications in process industry, where the risk for corrosion of compressed air system components is very high. Required compressed air quality according to standard ISO 8571-1 can be achieved with 9 different grades of filter elements. PF process filter housing can be used in variety of applications. For applications not listed please contact us or your local distributor. For any other technical gas please contact us or your local distributor. For oil removal, coalescing filter element must be installed and flow direction inside-out must be provided. General arrangement is bowl on the top and filter head on the bottom. Fluid group 1 on request.

Request for a quote

Germany

Gas Filters WITT gas filters allow the reliable filtration of the finest dirt particles in gases. Depending on the respective version, the gas filters can filter out particles from 3 to 40 micron and extend the service life of downstream equipment. The WITT gas filters provide high flow rates and multiple connections. WITT gas filters can be used for many technical gases. The gas filters – with or without condensation outlet – are designed for installation in pipelines or at outlet points. Gas filters can be changed while installed.

Request for a quote

Germany

CHARACTERISTICS high operating safety robust, compact design pressure resistant up to 350 bar easy maintenance flow direction selectable drag indicator as standard Dual scale bar / psi or mbar / kPa universally applicable selectable display indicating range OPTIONS helium application on demand plastic housing stainless steel housing static pressure max. 450 bar GENERAL The differential pressure gauge DP 900 serves to monitor the differential pressure of filter systems, measuring systems, valves, coolers, heat exchangers, in petrochemical, as well as in gas and air systems. Preferably, the DP 900 is applicable for air and gas technical systems. The gauge housing made from aluminum is designed compact and robust. It is pressure-resistant up to 350 bar. FUNCTION A determined path of a freely movable piston measures the differential pressure. The piston retains against a compression spring. The magnetic spool-measuring device unit is been installed to the main housing.

Request for a quote

United Kingdom

Sold as a pack of two these In-line HEPA filters are used to filter the CO2 supply to CO2 Incubators but can also be used for N2 and O2 gas supplies. Technical Specification: Pore Size (in microns) = 0.1 Micron Dimensions: h. 53.7 mm; w. 53.5 mm Filter media: Ceramic Paper Filtration Efficiency: 99.9999%* Filtration Ability: 0.027 Micron Effective Filtration Area: 22 cm2 Ring Colour: White Connections: 8mm Inlet Barb on each side to fit 6mm ID hose Flow: Bi-directional Autoclavable: N/A NOTE: Quantity discounts available on this product. Please contact us for a quotation.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business