Results for
ENVEA
France
The Natural Gas Sampling System 3000 is designed for very fast conditioning of samples from a pressurized natural gas source.
Request for a quoteBORSIG GMBH
Germany
BORSIG offers attractive process solutions for various gas separation applications in the fields of oil and gas production or refinery and process technology, such as BORSIG Hydrogen separation and BORSIG Fuel gas conditioning. This covers the treatment of gas streams for conditioning raw gas flows, recovery of specific components and the improvement of product quality to comply with customer gas specifications. Process concepts can be developed in addition to existing processes or as an alternative to conventional process solutions.
Request for a quoteGLOBAL GASES GROUP THAI CO LTD
Thailand
Chemical Formula: CCI3F (dichlorofluorcmethanel2. Molecular Weight: Approximately 137.37 g/mol3. Boiling Point: Approximately -24.70C (-12.5*F)4. Critical Temperature: 198.0*0 <388.40F)5. Critical Pressure: 4.88 MPa (approximately 49 oar or 711 psi)8. Density (at 0*C and 1 atm): Approximately 1.49 kg/m" 37. Ozone Depletion Potential (ODP): Historically, R11 had a high ODP, contriouting to ozone layer depletion.8. Global Warming Potential (GWP): Historically, R11 had a high GWP, contributing to climate change.
Request for a quoteGLOBAL GASES GROUP THAI CO LTD
Thailand
(Meets AHRI 700 2011 Specifications)Chlorodifluoromethane (R 22), wt %Maximum (unless otherwise noted)99.5 (minimum)Air and Other Non-condensable Gases, vol%Volatile Impurities, wt. %I ligh Boiling Residue, vol %Moisture (1120), ppm by wtAcidity, ppm by wt (as IICI)Chloride, no visible turbidity (indicates about 3 ppm)Particulates / solids (visually clean to pass)I lalogenated Unsaturated Volatile Impurities, ppm by weightPROPERTIES1.50.50.01101.0PassPass40Colorless liquefied gasFaint, ether-like odorAppearanceOdorMolecular Mass (g/mole)
Request for a quoteGLOBAL GASES GROUP THAI CO LTD
Thailand
HCFC-1410 is a hydrochic ref luorocarbon (HCFC). Its chemical name is 1,1-dichloro-1-flucroethane and its Chemical Abstracts Registry Number is 1717-00-6. HCFC-141b has been used as a solvent and as a foam blowing agent in the manufacture of diverse products ranging from refrigerators to building insulation. Under the U.S. Clean Air Act (Title VI. Section 602), HCFC-141b is a class II ozone-depleting substance (ODS). Under the Montreal Protocol, the group of HCFCs are listed as Annex C, Group I controlled substances.
Request for a quoteDo you sell or make similar products?
Sign up to europages and have your products listed
EMA INDUSTRY ENGINEERING SERVICES CO.
Turkey
EMA Industry Engineering is proudly serving the industry with state-of-art solutions and products. EMA is and Engineering and Suply company dealing with below fields; -Engineering and design works (Process & Mechanical) -Structural Engineering -Pig Receivers & Pig Launchers -Pipeline Pigs -Pressure Vessels -Vacuum Vessels -API Storage Tanks -Reactors -Suction Scrubbers -Oil Separators -Heat Exchangers (Shell and Tube) -Mud Tanks -Conditioning Skids (Fuel Gas Supply Systems) -Injection Units -Natural Gas Compression Packages -Stacks -Pressure Piping -Nitrogen Gas System -Columns EMA and its associates have both completed projects with varying complexities; from plant engineering to individual discipline engineering, small and large project scopes, and different engineering cost basis. The team provides technical capabilities for FEED, detailed engineering, plant modelling, project management, engineering studies, and construction services.
Request for a quoteCOSKUN KAUCUK SAN. TIC. A.S.
Turkey
Our company can produce rubber profiles with various dimensions for fixing clamps which are commonly used for fixing the pipes at natural gas installatons and air conditioning. They are resistant to ozone, corrosion, deformation and aging and can absorbe the vibration.
Request for a quoteSETNAG - EXPERT EN ANALYSE D'OXYGENE
France
Measurement of oxygen in gases Process control Brand : SETNAG ADVANTAGES : No need for reference gas: use of the MicroPoas® Semi in situ measurement (excellent reliability) Free circulation of the gases Easy and fast set-up Almost maintenance free, cost effective service MEASUREMENT TECHNIQUE The S24N-2020 analyser fits CEM systems Oxygen measurement on wet gas (direct connection at heated hose outlet) Oxygen measurement on dry gas (after sample conditioning) EXAMPLES OF APPLICATIONS Power generation, district heating operation... Incineration of industrial and domestic waste Steam production Steel works VOC incineration Control of processes...
Request for a quoteSETNAG - EXPERT EN ANALYSE D'OXYGENE
France
Measurement of oxygen in combustion gases Control of processes and measurement of emissions. QAL1 compliant (EN14181) Brand : SETNAG ADVANTAGES : No need for reference gas: use of the MicroPoas® Semi in situ measurement (excellent reliability) Free circulation of the gases you analyse Easy and fast set-up Limited and cost-effective service and maintenance operation MEASUREMENT TECHNIQUE The S24N-2020 analyser fits CEM systems Oxygen measurement on wet gas (direct connection at heated hose outlet) Oxygen measurement on dry gas (after sample conditioning) EXAMPLES OFAPPLICATIONS Power generation, district heating operations... Incineration of industrial and domestic waste Steam production Steel works VOC incineration Control of processes...
Request for a quoteResults for
Gas conditioning - Import exportNumber of results
10 ProductsCountries
Company type