Results for
Turkey
ETR Galvanic Isolation Transformers provide isolation between network installations and sensitive electronic loads. Insulated aluminum or copper windings are wound on a high efficiency sheet core. ETR transformers are vacuum-impregnated varnished and high-temperature dried to ensure quiet and moisture-proof operation. It is safe and long lasting.
Request for a quoteRomania
The LSP-IV2 isolator is designed to make galvanic isolation between the transmitter and the processing unit (PLC). With its 3 point galvanic isolation, it separates the input and the output from each other. This instrument is suitable for any industrial application where 0-5V or 0-10V analog signal is used. It reduces the impact of interference and ground potential differences. The module ensures 3500VDC isolation. Features • Three way isolated • 3500kV isolation • TS-35 DIN rail mounting • +/-0.1% accuracy • Ip40 case • Screw terminals • Power LED • 0-10V analog output • Supply voltage 24VDC • Made in EU
Request for a quoteSwitzerland
• Measurement of DC voltage, DC current, temperature (RTD, TC) and resistance • System capability: Parameterising and readout of all input variables and internally calculated values via MODBUS • Sensor connection without any external jumpers • 2 inputs (e.g. for sensor redundancy or difference formation) • 2 outputs (U and / or I) • DC- energy meter - function (with S0 output) • 2 inputs can be linked with each other and allocated to the 2 outputs which enables calculations and sensor monitoring (e.g. prognostic maintenance of sensors) • Freely programmable relay, e.g. for liwith or alarm signalling • Digital output (optional) • AC/DC wide-range power supply unit • Pluggable high-quality screw or spring cage terminals
Request for a quoteSwitzerland
• 3-way galvanic isolation • Spring-cage clamp connection • Power bridging terminal DIN rail bus connector • Small dimensions • Accuracy 0.1%
Request for a quoteSwitzerland
• 3-way galvanic isolation • Spring-cage clamp connection • Power bridging terminal DIN rail bus connector • Compact design, width only 6.2mm • Accuracy 0.1%
Request for a quoteSwitzerland
• 3-way galvanic isolation • Spring-cage clamp connection • Power bridging terminal DIN rail bus connector • Compact design, width only 6.2mm • Minimal range: 50 °C • Accuracy 0.1%
Request for a quoteSwitzerland
• Fast measurement of DC voltage, DC current, temperature (RTD, TC) and resistance • System capability: Parameterising and readout of all input variables and internally calculated values via MODBUS • Setting time up to 10 ms • Sensor connection without any external jumpers • 2 inputs (e.g. for sensor redundancy or difference formation) • 2 outputs (I) • 2 inputs can be linked with each other and allocated to the 2 outputs which enables calculations and sensor monitoring (e.g. prognostic maintenance of sensors). • Freely programmable relay, e.g. for liwith or alarm signalling • AC/DC wide-range power supply unit • Pluggable high-quality screw or spring cage terminals
Request for a quoteSwitzerland
• Measurement of DC voltage, DC current, temperature (RTD, TC) and resistance • System capability: Parameterising and readout of all input variables and internally calculated values via MODBUS • Sensor connection without any external jumpers • 2 inputs (e.g. for sensor redundancy or difference formation) • 1 output (U or I) • 2 inputs can be linked with each other and allocated to the 2 outputs which enables calculations and sensor monitoring (e.g. prognostic maintenance of sensors) • 2 freely programmable relays with changeover contacts, e.g. for liwith or alarm signalling • AC/DC wide-range power supply unit • Pluggable high-quality screw or spring cage terminals
Request for a quoteSwitzerland
• Measurement of DC voltage, DC current, temperature (RTD, TC) and resistance • Programmable remote I/O functionality. Readout of all input variables and internally calculated values via MODBUS. Simultaneously, the outputs and the relay may be controlled via MODBUS. • Free selection as to whether the output variables are dependent on the input variables or whether the outputs are controlled independently of the inputs via MODBUS. • Sensor connection without any external jumpers • 2 inputs (e.g. for sensor redundancy or difference formation) • 2 outputs (U and / or I) • 2 inputs can be linked with each other and allocated to the 2 outputs which enables calculations and sensor monitoring (e.g. prognostic maintenance of sensors) • System capability: Communication via Modbus interface • Freely programmable relay, e.g. for liwith or alarm signalling • AC/DC wide-range power supply unit • Pluggable high-quality screw or spring cage terminal
Request for a quoteGermany
The versatile, innovative weighing solution for truck silo / vessel weighing. The Weight Indicator X2 is available in a robust aluminium housing for front panel mounting and a stainless steel housing for field and table top mounting with FLP enclosure for hazardous zone. Utmost interference suppression and long term stability guarantees optimum use in harsh environments. 25 mm backlit transflective LCD display allows a good readability even under difficult conditions like direct sunlight. The high-quality sense-amplifier supports 4/6 wire load cells and allows connections over long distances without losing accuracy. Additional security is guaranteed by fully galvanically isolated sensor input circuit.
Request for a quoteTurkey
On-Line Double Conversion Technology Galvanic Isolation Transformer 2KVA-60KVA power range for Single phase 10KVA-200KVA power range for three phase IGBT and PWM technology Automatic By-Pass system Maintenance By-Pass Switch Internal Battery Option Extendable Battery Duration Operator Panel with LCD Display TS EN ISO 9001: 2015 Quality Certified It is produced on order
Request for a quoteBelgium
Measurement transmitter designed to convert any notnormalised DC voltage or current signal into a normalised signal while providing galvanic insulation. o Voltage or current input o Galvanic isolation 2 kV RMS. 50 Hz during max. 60 s between input, output and power supply o Selection of input and output ranges by jumpers behind the front plate o Wide range of power supplies o Rail DIN mounting Compliant with EMC EN 500822
Request for a quoteGermany
The RC5 can be supplied with an IOM on request to provide control and indication functions. IOM has 12 galvanically isolated digital inputs and 12 digital outputs with normally open and normally closed contacts.
Request for a quoteGermany
The RC5 can be supplied with an IOM on request to provide control and indication functions. IOM has 12 galvanically isolated digital inputs and 12 digital outputs with normally open and normally closed contacts.
Request for a quoteRomania
This device splits the analog input into two outputs, identical to the input signal and in the same time, it ensures a galvanic isolation. Order CodeInput Output1 Output2 LSP-IAS-0200(4)-20mA0(4)-20mA0(4)-20mA LSP-IVS-0100-10V 0-10V 0-10V LSP-IVS-0050-5V 0-5V 0-5V Features • Four way isolated • 3500VDC isolation • TS-35 DIN rail mounting • +/-0.1% accuracy • Ip40 case • Screw terminals
Request for a quoteRussia
3stage rectifier and inverter conversion technology Builtin load galvanic isolation transformer Low input THDi (<3%) Digital Control Technology (DSP Control) High output power factor 1 Intelligent battery management Advanced communication capabilities Parallel installation of up to 8 UPSs Robust and reliable design
Request for a quoteGermany
Non-contacting multi-channel speed sensor with square wave output signal, brass threaded tube, difference-hall-effect or inductive magnetic principle. Due to its design and its approvals especially suitable for shipbuilding industry. Robust housing: IP66/68 Excellent vibration and shock resistance Variable lengths, threads and electrical connections Optionally with two galvanically isolated output signals Optionally with additional status signal (e. g. direction of rotation detection) Approvals: ABS, BV, DNV-GL, LR
Request for a quoteDo you sell or make similar products?
Sign up to europages and have your products listed
Germany
Galvanic non-isolated LED Display Rugged construction Over temperature protection Input filter versus disturbances of thyristors drives up to 400V Wide input voltage range Regulated output Dual output voltage (12VDC and 24VDC)
Request for a quoteGermany
Galvanic non-isolated DC/DC wide range input Rugged construction Parallel connectable without control lead Input filter versus disturbances of thyristors drives Efficiency up to 95% Non-isolated output Regulated output
Request for a quoteGermany
Galvanic non-isolated DC/DC wide range input Rugged construction Parallel connectable without control lead Input filter versus disturbances of thyristors drives Efficiency up to 95% Non-isolated output Regulated output
Request for a quoteGermany
Galvanic non-isolated DC/DC wide range input Rugged construction Parallel connectable without control lead Input filter versus disturbances of thyristors drives Efficiency up to 95% Non-isolated output Regulated output
Request for a quoteGermany
DC/DC wide range input Input filter versus disturbances of thyristors drives Rugged construction Parallel connectable without control lead Efficiency up to 95% Non-isolated output Regulated output Galvanic non-isolated
Request for a quoteGermany
Multifunctional device for frequency input and monitoring. Measurement of up to 2 speed signals with slip or offset measurement. Direction of rotation detection. Free programmable speed range. 2 galvanically isolated norm signal outputs (0...5 V, 0...10 V, 2...10 V, +/-5 V, +/-10 V, 4...20 mA or 0...20 mA). 6 potential-free relais outputs with normally open switch. Short-circuit- and overvoltage proof outputs. Simple mounting and operation. Approvals: Marine ABS, BV, DNV-GL, LR, NK, KR
Request for a quoteGermany
Non-contacting speed sensor type FA54 withNon-contacting speed sensor type FA54 with aluminium flange and stainless steel sensor tube. Due to its design and its approvals especially suitable for the shipbuilding industry. Robust and high quality housing: IP68 pressure-tight Excellent vibration and shock resistance High degree of EMC immunity for difficult electrical environment Connection outlet straight or lateral; with protective tubing on request Up to four output signals, on request available with one status signal for rotational direction detection, on request with two galvanically isolated output signals
Request for a quoteGermany
Non-contacting multi-channel speed sensor with square wave output signal, stainless steel threaded tube, difference-hall-effect or inductive magnetic principle. Due to its design and its approvals especially suitable for shipbuilding industry. Robust housing: IP66/68 Excellent vibration and shock resistance Variable lengths, threads and electrical connections Optionally with two galvanically isolated output signals Optionally with additional status signal (e. g. direction of rotation detection) Approvals: ABS, BV, DNV-GL, LR
Request for a quoteSwitzerland
• 3-way galvanic isolation • Spring-cage clamp connection • Power bridging terminal DIN rail bus connector • Compact design, width only 6.2mm • Accuracy 0.1% • With power supply for 2-wire transmitter
Request for a quoteSwitzerland
• 3-way galvanic isolation • Spring-cage clamp connection • Power bridging terminal DIN rail bus connector • Compact design, width only 6.2mm • Accuracy 0.1%
Request for a quoteSwitzerland
CYK10 guarantees absolute water-proof connection of Memosens sensors to the transmitter. Its inductive coupling shows no contact corrosion and guarantees galvanic isolation of transmitter and medium. Simply forget about limited cable length, interfering potentials or moisture and benefit from completely safe and reliable signal transmission.
Request for a quoteSwitzerland
The RB223 passive barrier can be used to galvanically isolate active signal circuits (0 to 20 mA) in three applications:Transmission from non-Ex to Ex areas e.g for active adjusters, controllers or indicators, Transmission from Ex to non-Ex areas for connection of active, intrinsically safe circuits to the PLC, Transmission from Ex to non-Ex areas for supply of intrinsically safe transmitters with non-intrinsically safe transmitter power supply.
Request for a quoteResults for
Galvanic isolators - Import exportNumber of results
37 ProductsCompany type
Category