• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • calibration equipment

Results for

Calibration equipment - Import export

Manufacturer/producer

Germany

Verified by Europages

The precision RTD simulator is used where measuring instruments or controlling means with high precision must be examined or calibrated. The simulator is suitable for calibration laboratory and service centers which need a computer-controlled resistance decade for the automation of calibration procedures. All standard platinum and nickel RTD can be simulated with very high accuracy according to scales ITS 90 or IPTS 68. Temperature regulators, transducers etc. often supply a pulsed signal current in order to reduce the self-heating of the RTD. Devices with electronic simulation of RTD are therefore inclined to swinging and do not function with this application. Features: — Simulation of Pt100, Pt200, Pt500, Pt1000, Ni100 and Ni1000 sensors — Accuracy 0.02 °C — Temperature scales ITS 90, IPTS 68 — Real Ohm simulation — Control manually or remotely via RS232/IEEE488/USB Converter

Request for a quote

Germany

Verified by Europages

The precision calibration unit combines high accuracy, low drift, low noise and superior long-term stability with multiple functionality and simple operation. Ramps, Δ+/Δ-, and multiple setpoint storage make the operation of the device easier for the user. For that reason the application possibilities are many: — Calibration of current and DC-voltage meters — Precise testing of thermocouple temperature measuring instruments — Calibration of controllers, sensors, detection devices and other devices used in process control — Open-loop process control with the aid of integrated ramp function Features: — High precision current and voltage source ± 52 mA, ± 30 V — Option: ± 22 mA, ± 60 V — Precision simulation for all conventional thermocouple types (optional) — Error limit 0.003 % Rdg. — Standard with RS232 and IEEE488 interface, USB and Ethernet (optional) — Current "SINK"

Request for a quote

Germany

Verified by Europages

The DIGISTANT® model 4420 universal calibrator, built to use in the field, is ideal for checking and calibrating temperature measurement and control devices. The versatile functions of this portable unit allow to be used on-site or at a fixed location, on the test floor or in the laboratory. The unit allows the simulation and measurement of voltages, currents, temperatures and resistances.Simultaneous transmission and measurement allow, for example, controllers to be checked precisely. The automatic ramp function is used for controlling processes. The universal calibrator measures and simulates 14 models of thermocouples and Pt100. Features: Calibration and measurement unit for voltages, currents, temperatures and resistances All functions can be fully controlled and configured via RS232 interface Simultaneous transmission and measurement Automatic ramp function Simple menu assistance via display Voltage range ± 1 μV to ± 11.000 V Current range ± 200 nA to ± 22.000 mA

Request for a quote

Germany

Verified by Europages

Wherever temperatures are measured, temperatures must also be simulated. The Pt100-simulator is suitable for a wide area of applications. It has a wide range of simulation, which is resolved in 0.1 °C steps and makes many assignments in chemistry-, measuring-, controlling-, medicine and household applications, food industry, vehicle construction, air- and space travel and power plants easy to solve. Often in the past several simulators had to be used alongside to achieve either resolution or the range of the relevant application. As an extra advantage to the user temperatures can be entered in degrees celsius. Additional extensive conversions and readings in tabulation sheets are no longer necessary. Features: — Simulation range -100 °C up to +500 °C — Resolution 0.1 °C — Calibration in accordance to DIN EN 60751 — Simulation of line resistance 10 Ω, 20 Ω or 30 Ω — Sturdy aluminium-housing

Request for a quote

Germany

Verified by Europages

The force measuring chain is an universal reference measuring chain for the calibration of press-fit force measuring equipment. It finds applications in the quality assurance, commissioning and equipment monitoring fields. A DAkks calibration certificate is included so that the force measuring chain can be traced back. The calibration is traceable through accreditation at the German Accreditation Body. The calibration certificate records the displayed values for mounting positions at 0°, 120° and 240°. During calibration in field, the reference load cell is inserted in line with the flux of the press-fit measuring equipment. The force application is of central significance here for the quality of the measurement. Special force application parts are required, so that the line of action of the force agrees as exactly as possible with the geometrical axis of the load cell that is to be measured (central loading).

Request for a quote

Germany

Verified by Europages

The multipurpose digital indicator TRANS CAL 7281 can be used wherever there is a need to perform high-precision, in-situ calibrations of sensing components used in equipment such as presses, torque tools or pressure-regulating systems. An optional factory calibration certificate or German-accredited DKD/DAkkS calibration certificate can be provided when the measurement device needs to be used as a reference. This provides a quick and cost-effective way of assessing a system with traceable documentation of measurement results. If a reference measurement cannot be made because the sensor location is difficult to access, it is still possible to test the zero point, the input, output and isolation resistance as well as the calibrating offset of the fitted sensor. It is also possible to check the indicating device by measuring the excitation voltage and simulating the characteristic values (mV/V or V) of the sensor used.

Request for a quote

Germany

Verified by Europages

High-precision angle measuring system with +/-0.1s accuracy for measuring and calibration applications. The signal sampling is done by an interferometric operating principle (laserscale) The graduation period is 1µm, the generated signal period of the output signal is 250nm. Scale errors are self-compensated by using six reading heads in a special arrangement. The measured values can be output in csv format via the USB interface. The software for measured value acquisition and storage is included in the scope of delivery.

Request for a quote

Germany

Verified by Europages

This high-precision calibration source is able to measure currents up to ±50 mA, voltages ±100 V and temperature setpoint values of 12 thermocouple types, including R, S, B, J, T, E, K and N. Voltage drops across the measuring leads can be easily compensated via the sense line. With “thermoelectric voltage simulation” you can enter °C, °F and K, the temperature scales ITS-90 or IPTS-68 and the reference junction type constant/external. Furthermore, when simulating thermocouples a calibrated external reference junction can be used, with the calibration data being taken into account in the device. The device can be operated both via the keypad and via the Ethernet and USB interface. Features: — DC voltage up to ±100.0000 V, ±0.002 % — DC current up to ±50.0000 mA, ±0.005 % - Thermocouple simulation of R, S, B, J, T, E, K, N, M, C, D, G2 - Automatic sequence function (ramp function)

Request for a quote

Germany

Verified by Europages

The precision Pt100 simulator is used wherever measuring instruments or controlling systems have to be tested or calibrated with great precision. The standard version model 4506 simulates 24 set temperature values. Totally different temperature ranges are required in the case of special applications, such as in the food industry, the medical science etc. Model 4506 S is recommended for these applications and can be fitted with 24 temperature values according to customer specifications. A distinctive feature of these simulators is their simple operation. The resistance values required for simulation are directly set in °C. There is no need to use loof-up tables. Today in many cases a certificate is needed more than ever force measurements. This certificate is available under order code 45DKD-.. . Features: 24 set temperature values Calibration per DIN EN 60751 Resistor material: MANGANIN®, TK ≤ 10 ppm/K Pt100, Pt500, Pt1000 Available with DKD Certificate if required

Request for a quote

Germany

Maintain the high accuracy of your BlowerDoor measuring technology by regularly submitting it to a calibration. Benefit from the high accuracy of the BlowerDoor measuring technology: At ± 4% or rather ± 5% (flow rings D + E), the accuracy of the BlowerDoor testing flow rings – as well as that of the pressure gauge DG-700 (± 1%) or DG-1000 (± 0.9 %) – clearly exceed the minimum legal requirements. The manufacturer’s calibration as well as the calibration with DAkkS-certificate, are subject to the highest quality standards. When calibrated, all measuring systems undergo a preceding functional test. If required, we will gladly provide you with a replacement device at favorable rates and conditions, while your BlowerDoor measuring system is being calibrated or repaired.

Request for a quote

United Kingdom

Model 5214 Standard Test Gauge Our 0.25% accuracy Standard Test Gauge is undoubtedly recognised as a world leader for its accuracy and, of course, Budenberg Quality. This gauge incorporates a base test gauge accuracy with to a maximum of 500 graduations where possible, along with a knife edged pointer and an anti parrallax mirror to help reduce the chance of human error. Model 5314 MasterTest Gauge The 5314 now provides a higher specification and incorporates many additional features as standard. Housed in a new die-cast safety pattern case, the 5314 meets the full requirements of EN837 including a brighter anti-parallax mirror scale & knife-edge pointer for accurate repeatable readings. Model 5414 Super Test Gauge The 5414 now provides a higher specification and incorporates many additional features as standard. Housed in a new die cast safety pattern case, the 5414 meets the full requirements of EN837.

Request for a quote

United Kingdom

The Classic range of Pressure Gauges has been designed to meet the high demands of the process industry. From harsh corrosive chemical applications to general engineering uses, the Classic combines a high specification with a very cost-effective price. The standard unit incorporates 316 stainless steel wetted parts that are housed within a liquid fillable 316 stainless steel case. Standard units are available as dual scale bar and psi but custom scales can be supplied. 316L wetted parts and cases are available as an option. Available with a wide range of accessories including: Syphons, Snubbers, Gauge Savers, Manifolds, Diaphragm Seals etc ensures that Budenberg can provide you with the right product to suit any individual application or requirement. Scale Ranges: 0 to 1 bar to 0 to 1400 bar or equivalent units of pressure / vacuum are available. Size: 100 mm (4”) & 150mm (6") Mounting: Direct, Flush or Surface

Request for a quote

United Kingdom

Bourdon Tube Pressure Gauge - Defence Standard Designed for Naval and Marine applications in accordance with Def Stan 66-2. This gauge has been designed to withstand high level of shock and are all manufactured in accordance with EN837 -1. The 4" and 6" flush mounting versions are available with 3 Hole front fixing flange . Bourdon Tube Oxygen Pressure Gauge The 950GP incorporates a solid baffle wall and blow-out back for operator protection and standard features such as IP67 environmental protection, not normally available on comparative units. The 950GP is specifically manufactured for use on OXYGEN and as such is cleaned for Oxygen service with no oil or grease contamination. A restrictor in the inlet is a standard feature. BFMIRA Vacuum Gauge (Can Piercing Test) The Model 269 is a high specification vacuum gauge specifically designed for the estimation of the intensity of vacuum in a food can. Developed by the British Food Manufacturing Industries Research Association.

Request for a quote

United Kingdom

The BGH series base can be used with any of the BGH series pistons to give ranges 1-120 bar with a BGH120, 2-300 bar with a BGH300, 1-700 bar with a BGH700 and 1-1200 bar with a BGH1200 . All units are top loading for ease of use and weight sets are fully interchangeable. This means that weight sets in alternative pressures are readily available and customers with more than one %*+ series tester can interchange weight sets between testers of the same range. The base features a dual area screwpress which allows low-pressure priming and high-pressure control. The BGH is a robust design, proven over many years usage. The unit has a 1/16in2 fully hardened and stabilised tool steel piston. This unit gives extremely good sensitivity for high accuracy calibration, yet is tough enough for regular use in a workshop environment.

Request for a quote

United Kingdom

Schaffer Diaphragm gauges are designed for use on slurries, viscous or corrosive fluids that would normally attack or block standard bourdon tube gauges. 316 Stainless Steel full safety pattern case. Implementing specialist materials for both the connection and diaphragm enable the Shaffer Diaphragm gauge to be configured for use on any gaseous or liquid media including suspended solids or powders. The direct drive from the diaphragm to the movement ensures a more positive indication of pressure than other models of tube gauges. Offering a full range of screwed connection sizes and materials, Schaffer Diaphragm gauges can operate at pressure ranges as low as 30 mBar with the option to permit units to withstand a maximum pressure of 70 bar.

Request for a quote

United Kingdom

Sizes: 63 mm & 80mm Dial diameter and 100 mm (4”) & 150mm (6") Mounting: Direct, Surface and Flush Case & Bezel: Full Safety Pattern case to S3 standard and Die Cast Scale Ranges: 0 to 600 mbar to 0 to 1400 bar, 0 to 400 mBar up to 0 to 1400 Bar Pressure Element: ≤80 Bar for 316 Stainless Steel Bourdon Tube and ≥81 Bar for 316 Stainless Steel Coil Overload: Up to 130% of FSD Pressure Connection in 316 Stainless Steel: 3/8”, 1/2” BSP and 1/2" NPT Accuracy Class: 1% of FSD (CL1) as defined in EN837-1 (Options available) Operating Temperature: -20 to +90 ºC operating Dial: White Anodised Aluminium marked in black finish Pointer: Stainless steel coloured black Movement: Stainless Steel Construction Window: 3mm Laminated Safety Glass (Standard) Environmental Rating: IP67 as defined in EN 60 529 Traceability: Calibrated with unique Serial Number printed on the dial Certification: BS EN 10204 3.

Request for a quote

United Kingdom

The BGP base can be used with any BGP series piston, allowing testing from 15 mbar to 120 bar. The base requires a supply of gas slightly above test pressure, and has precision inlet / outlet valves and a screwpress to enable easy regulation and adjustment of pressure. The BGP1 has a 1/2in2 high chrome steel piston/cylinder unit. The design has been proven over many years to provide excellent sensitivity and stability. Low start pressure is achieved through use of a hollow piston and aluminium head. NOTE: Model BGP1 can be used on vacuum with a model 24 adaptor. All certificates issued for Budenberg Dead-weight Testers are fully traceable to national standards via equipment with UKAS calibration certificates.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

United Kingdom

Model 179 Differential Pressure Gauge The gauge is designed to withstand full working pressure, applied separately to either connection or together. The maximum working pressure should not be exceeded even temporarily, so the possibility of surging pressures should be considered when selecting the instrument. Model 180 Microvar Differential Pressure Gauge Melinex is a polyester film (polyethylene terephtalate) that is resistant to all petroleum refining industry fluids. Please consult our technical department to check the suitability for other chemicals. Model M24 Bellows Type Differential Pressure Gauge Designed around a balanced bellows system, which converts the differential pressure into a rotary movement by way of a torsion tube assembly and mechanical linkages. The entire assembly is liquid filled, producing a hydraulic self lubricating measurement system which allows for full line pressure to be applied to either side of the unit without damage to the device.

Request for a quote

Germany

The KAL 100 / 200 calibration device combines a pressure transmitter and pressure gauge. These can be used to test and calibrate pressure sensors and other pressure gauges for low pressures both quickly and easily. The desired pressure is indicated on the digital display and pressure is generated quickly and precisely through the use of a closed loop, thereby eliminating the need for an external pressure generator.

Request for a quote

Germany

The portable, battery-operated KAL 84 calibration system combines a pressure transmitter and pressure gauge. These can be used to test and calibrate pressure sensors and other pressure gauges for low pressures both quickly and easily. A high degree of accuracy and excellent reproducibility of results combined with a robust design give the system all the functionalities required for laboratory and service applications. Calibration in mmHg (optional) makes the system ideal for applications in accordance with the regulations for users of medical products, e.g. blood pressure monitors and infusion/suction pumps.

Request for a quote

Poland

Verified by Europages

We maintain quality assurance systems, such as iso 9001: 2009, iso 18001-2004 and iso 14001-2005. KIGEMA possesses a laboratory allowing testing the mechanical properties of products like hardness, elongation, and micrometer. KIGEMA also conducts penetration and ultrasonic tests and issues certificates of conformity with EN 10204-2.2, 2.3, 3.1B. Additionally, the company has an air-conditioned measuring room equipped with High-quality measuring equipment, which is regularly calibrated. The measuring equipment includes: calipers, altimeter, depth calipers, inside micrometers, bore gauges, outside micrometer and roughness tester.

Request for a quote

Russia

While introducing a new line of gas analysis equipment to the market, we offer a fundamentally new concept of gas analysis systems based on replaceable modular gas analyzers GAOS SENSON-SM-9001. Advantages: - Radically reduced downtime required for calibration and repair - Reduced spare equipment costs - Increase the offline resource of remote objects - Extra-low delivery times New concept: - simplifies the replacement of gas analyzers for calibration and in the event of a malfunction – in the case of GAOS SENSON it is as simple as changing a light bulb, no need to dismantle/change the entire device. That is, it is enough to change a lightbulb, not a chandelier; - it dramatically reduces the stock of replacement systems in volume and cost – only the GAOS SENSON-SM-9001 modules are needed (supply of light bulbs, not chandeliers); - requirements for the qualification of staff (there is only one requirement – accuracy) are reduced.

Request for a quote

Germany

To ensure that an instrument provides accurate measurements, regular calibrations are necessary. Calibration means to operate a target-performance comparision using a measuring instrument and a traceable reference. Calibration of instruments is essential in every area where sensitive measurement technology is used, e.g. in the manufacturing of sensors. It is the only way to guarantee quality standards and prevent defects arising in processes and products from the outset. For companies wanting to attain ISO 9001 certification, regular calibration of testing equipment is a requirement. halstrup-walcher has been accredited by the German calibration service DKD and Deutsche Akkreditierungsstelle GmbH (DAkkS) as a calibration laboratory in accordance with DIN EN ISO / IEC 17025 since 1999 – among other things for calibration of pressure measurements.

Request for a quote

France

The Oxygas 500 compliments the Gascoseeker 500 with a similar performance, measuring % LEL and % volume flammable hydrocarbons, but with the addition of oxygen for either gas/air or gas/nitrogen/air purging. The Oxygas 500 has the following additional features; automated zero during start-up, manually selectable purge mode. The P-500 variant has an additional part per million (ppm) range of methane. The Oxygas 500 is easy to use with very simple training, as the operation of the instrument follows the operation of the purge cycle. The rugged design allows the Oxygas 500 to be used in harsh environments. The instrument is also fully compatible with our range of calibration software and equipment.

Request for a quote

France

Built on the success of the robust and reliable Gascoseeker MK2, the Gascoseeker 2-500 is the UK gas industry standard instrument for measuring % LEL and % volume flammable hydrocarbons, with over 20,000 instruments in use in the UK gas industry. The two-button operation means the Gascoseeker 2-500 is easy to use and operator training can be conducted quickly. The rugged design allows the Gascoseeker 2-500 to be used in harsh environments. The Gascoseeker 2-500 is also fully compatible with our range of calibration software and equipment.

Request for a quote

Ukraine

Compact two-stage calibrator (CANDY ROPE SIZER) This is the optimal solution for supplementing an existing line of equipment or as an independent unit of equipment for calibrating a caramel bundle to the right size before moulding candy such as a "pad," lollipops on a handmade stick and other products. The main advantages of our equipment are: · PROFITABLE To start production of caramel you will need minimum production capacity · PRACTICAL The calibrator can be embedded in an existing caramel line · QUICK REPLACEMENT OF SIZING ROLLERS Sizing rollers are easily dismantled to fit rollers with the required cross section · WIDE RANGE OF BUNDLE CALIBRATION SIZES Optional sizing rollers from 8mm to 20mm · RELIABLE DESIGN The calibrator has a rigid hull design and is equipped with an industrial reduction motor that allows you to work in NON-STOP mode for a long time · FULL COMPLIANCE During the development of the calibrator, all hygienic standards were taken into account.

Request for a quote

Turkey

-Static Pressure Test Equipment -LOSS OF PRESSURE TEST EQUIPMENT -WATER METER ENDURANCE (ABRASION) TESTING EQUIPMENT -HEAT METER DURABILITY TEST EQUIPMENT -DOMESTIC WATER METER TEST AND CALIBRATION EQUIPMENT -WOLTMAN WATER METER TESTING EQUIPMENT -HEAT METER TEST AND CALIBRATION EQUIPMENT -MOBİLE TEST UNIT

Request for a quote

Germany

The TransiTec Big Bag filling stations are suitable as standard for filling big bags with a capacity of up to 2 tons. Various options are available to meet the required task. Also a calibratable weighing of the filled Big-Bas. The Big-Bag filling station offers a variety of options: - height-adjustable suspension frame - Tightening of the big bag by means of linear drive - Double big bag filling - vibration table for compacting the products, etc., ... to name just a few.

Request for a quote